What is the maximum glass light size on a 90 min (1 1/2 hour) fire rated door?
Standard listed wire glass: one (1) light with 100 in2 per door leaf max.Firelite or other appropriately listed glass:• FM maintains one (1) light with 100 in2 per door leaf max.• UL &am...
Schlage Commercial » Doors and Frames » Doors » B Series » Steelcraft | Schlage Commercial » Doors and Frames » Doors » CE Series » Steelcraft | Schlage Commercial » Doors and Frames » Doors » L-Series » Steelcraft | Schlage Commercial » Doors and Frames » Doors » SL Series » Steelcraft | Schlage Commercial » Doors and Frames » Doors » T Series » Steelcraft | Schlage Commercial » Steelcraft
What is the standard Steelcraft door thickness?
1 3/4" is the standard door thickness. Steelcraft only makes a nominal 1 3/4" thick door. A 1 3/8" was made for light duty commercial applications but that product was discontinued in 1999....
Schlage Commercial » Doors and Frames » Doors » B Series » Steelcraft | Schlage Commercial » Doors and Frames » Doors » CE Series » Steelcraft | Schlage Commercial » Doors and Frames » Doors » H Series » Steelcraft | Schlage Commercial » Doors and Frames » Doors » L-Series » Steelcraft | Schlage Commercial » Doors and Frames » Doors » SL Series » Steelcraft | Schlage Commercial » Doors and Frames » Doors » T Series » Steelcraft | Schlage Commercial » Steelcraft
Are doors available for use with non Steelcraft window kits?
Doors are available with cutouts only. This practice is used for field installation of aftermarket (non-Steelcraft) glass trim by either the distributor or end user. The following information must be ...
Schlage Commercial » Doors and Frames » Doors » B Series » Steelcraft | Schlage Commercial » Doors and Frames » Doors » CE Series » Steelcraft | Schlage Commercial » Doors and Frames » Doors » H Series » Steelcraft | Schlage Commercial » Doors and Frames » Doors » HE Series » Steelcraft | Schlage Commercial » Doors and Frames » Doors » L-Series » Steelcraft | Schlage Commercial » Doors and Frames » Doors » SL Series » Steelcraft | Schlage Commercial » Doors and Frames » Doors » T Series » Steelcraft | Schlage Commercial » Steelcraft
What are the standard hinge and lock spacing for doors and frames?
Lock Spacing: All standard bored locks ANSI 115.2 (161, 61L type), for mortise lock ANSI 115.1 (86 type) all locations must be altered 3/8" lower, and standard strike (ASA type). 1. Opening ...
Schlage Commercial » Doors and Frames » Doors » A14 Series » Steelcraft | Schlage Commercial » Doors and Frames » Doors » B Series » Steelcraft | Schlage Commercial » Doors and Frames » Doors » CE Series » Steelcraft | Schlage Commercial » Doors and Frames » Doors » H Series » Steelcraft | Schlage Commercial » Doors and Frames » Doors » L-Series » Steelcraft | Schlage Commercial » Doors and Frames » Doors » Paladin PW Series » Steelcraft | Schlage Commercial » Doors and Frames » Doors » SL Series » Steelcraft | Schlage Commercial » Doors and Frames » Doors » T Series » Steelcraft | Schlage Commercial » Doors and Frames » Frames » DW & K Series » Steelcraft | Schlage Commercial » Doors and Frames » Frames » F & FN Series » Steelcraft | Schlage Commercial » Doors and Frames » Frames » FE & DE Series » Steelcraft | Schlage Commercial » Doors and Frames » Frames » MU Series » Steelcraft
What are the standard door and frame clearances?
To determine Actual Door Size, the following values are subtracted from nominal door size (frame opening/order size) Actual Door Size: The largest measured width by height of the door leaf as manu...
Schlage Commercial » Doors and Frames » Doors » A14 Series » Steelcraft | Schlage Commercial » Doors and Frames » Doors » B Series » Steelcraft | Schlage Commercial » Doors and Frames » Doors » CE Series » Steelcraft | Schlage Commercial » Doors and Frames » Doors » H Series » Steelcraft | Schlage Commercial » Doors and Frames » Doors » L-Series » Steelcraft | Schlage Commercial » Doors and Frames » Doors » SL Series » Steelcraft | Schlage Commercial » Doors and Frames » Doors » T Series » Steelcraft | Schlage Commercial » Steelcraft
What is the hinge backset for 1 3/4" thick door?
Hinge backset is the dimension from the leading edge of the hinge to either the stop on the frame or to the stop face (push side) of the door. For operating clearance, the hinge backset on the door...
Schlage Commercial » Doors and Frames » Doors » A14 Series » Steelcraft | Schlage Commercial » Doors and Frames » Doors » B Series » Steelcraft | Schlage Commercial » Doors and Frames » Doors » CE Series » Steelcraft | Schlage Commercial » Doors and Frames » Doors » H Series » Steelcraft | Schlage Commercial » Doors and Frames » Doors » L-Series » Steelcraft | Schlage Commercial » Doors and Frames » Doors » Paladin PW Series » Steelcraft | Schlage Commercial » Doors and Frames » Doors » SL Series » Steelcraft | Schlage Commercial » Doors and Frames » Doors » T Series » Steelcraft | Schlage Commercial » Doors and Frames » Frames » DW & K Series » Steelcraft | Schlage Commercial » Doors and Frames » Frames » F & FN Series » Steelcraft | Schlage Commercial » Doors and Frames » Frames » FE & DE Series » Steelcraft | Schlage Commercial » Doors and Frames » Frames » MU Series » Steelcraft | Schlage Commercial » Steelcraft
How is glass cutting size figured for standard or special glass light installed?
The GCS (Glass Cutting Size) is determined by adding 1 1/4" to EGS (Exposed Glass Size) to both the height and width dimensions. Ex: EGS = 20" w. x 30" h. GCS = 21 1/4" wide x 31 1/4" high Steel...
Schlage Commercial » Doors and Frames » Doors » B Series » Steelcraft | Schlage Commercial » Doors and Frames » Doors » L-Series » Steelcraft | Schlage Commercial » Steelcraft
Can doors be prepared for raceways in the factory?
Raceway availability: Optional factory installed raceways are available in doors but are not available in frames. Preparation Info: Steelcraft installs a flexible 3/4" ID steel co...
Schlage Commercial » Doors and Frames » Doors » B Series » Steelcraft | Schlage Commercial » Doors and Frames » Doors » CE Series » Steelcraft | Schlage Commercial » Doors and Frames » Doors » H Series » Steelcraft | Schlage Commercial » Doors and Frames » Doors » L-Series » Steelcraft | Schlage Commercial » Doors and Frames » Doors » T Series » Steelcraft | Schlage Commercial » Steelcraft
What are the thermal factors for Steelcraft door products?
All doors are tested in accordance with ASTM C1363 and SDI 113:B18 Series (Steel Stiffeners)     U-Factor = 0.50     R-Value = 2.01B16 Series (Steel Stiffe...
Schlage Commercial » Doors and Frames » Doors » B Series » Steelcraft | Schlage Commercial » Doors and Frames » Doors » CE Series » Steelcraft | Schlage Commercial » Doors and Frames » Doors » H Series » Steelcraft | Schlage Commercial » Doors and Frames » Doors » L-Series » Steelcraft | Schlage Commercial » Steelcraft
What are the minimum stile and rail dimensions for the L-Series door FG, FG2 & FG3?
The minimum stile and rail dimensions are to exposed glass are: Stiles = 6 13/16" Top Rails = 6 3/4" Center Rails = 7 1/2" Bottom Rail = 10 3/4" For high traffic and high abuse locations the A...