Category: Benchmark

(Results from 11 to 20)
What is 8310-3883?
The 8310-3883 is a safety sensor package for a single door.  It is required with our 4600, Benchmark, Falcon, and Pneumatic operators when an approach side Door Mount Safety Sensor will be used...
Schlage Commercial » Automatic Operators | Schlage Commercial » Automatic Operators » Actuators | Schlage Commercial » Automatic Operators » Actuators » Actuators and Accessories | Schlage Commercial » Automatic Operators » Actuators » Actuators and Accessories » LCN | Schlage Commercial » Automatic Operators » Sensors | Schlage Commercial » Automatic Operators » Sensors » Sensors and Accessories | Schlage Commercial » Automatic Operators » Sensors » Sensors and Accessories » LCN | Schlage Commercial » Automatic Operators » Electrohydraulic | Schlage Commercial » Automatic Operators » Electrohydraulic » 4630 Series | Schlage Commercial » Automatic Operators » Electrohydraulic » 4630 Series » LCN | Schlage Commercial » Automatic Operators » Electrohydraulic » 4640 Series | Schlage Commercial » Automatic Operators » Electrohydraulic » 4640 Series » LCN | Schlage Commercial » Automatic Operators » Electromechanical | Schlage Commercial » Automatic Operators » Electromechanical » 8200 Series | Schlage Commercial » Automatic Operators » Electromechanical » 8200 Series » Falcon | Schlage Commercial » Automatic Operators » Electromechanical » Benchmark | Schlage Commercial » Automatic Operators » Electromechanical » Benchmark » LCN | Schlage Commercial » Automatic Operators » Electromechanical » Senior Swing | Schlage Commercial » Automatic Operators » Electromechanical » Senior Swing » LCN | Schlage Commercial » Automatic Operators » Pneumatics » 2610 Series | Schlage Commercial » Automatic Operators » Pneumatics » 4810 Series | Schlage Commercial » Automatic Operators » Pneumatics » 4820 Series | Schlage Commercial » Automatic Operators » Pneumatics » 4840 Series
What is the opening force for the 9100 Benchmark?
Without power boost turned on, the Benchmark manual opening force is approximately 33N (7.5 lbs.) of force....
Schlage Commercial » Automatic Operators » Electromechanical | Schlage Commercial » Automatic Operators » Electromechanical » Benchmark | Schlage Commercial » Automatic Operators » Electromechanical » Benchmark » LCN
What can cause a Benchmark operator to squeak during operation?
First thing to check is installation-   Make sure installation is good, especially make sure the back plate is sitting flat and that the frame is plumb, otherwise there is potential that t...
Schlage Commercial » Automatic Operators » Electromechanical » Benchmark | Schlage Commercial » Automatic Operators » Electromechanical » Benchmark » LCN
On an LCN Benchmark operator does the location of Power Boost change based on the latch position?
No, on the Benchmark, Power Boost does not change locations based on the latch position setting.  If Power Boost is turned on it will come in at approximately 10 degree no matter what setting the...
Schlage Commercial » Automatic Operators » Electromechanical » Benchmark | Schlage Commercial » Automatic Operators » Electromechanical » Benchmark » LCN
What diode (for use with Electric Strikes) is sent out with the LCN Sr Swing and Benchmark operators?
The diode is a 1N4148 diode. The diode is shipped in the ES filter kit.  See here for photo a Sr Swing ES filter kit.   ...
Schlage Commercial » Automatic Operators » Electrohydraulic | Schlage Commercial » Automatic Operators » Electromechanical | Schlage Commercial » Automatic Operators » Electromechanical » Benchmark | Schlage Commercial » Automatic Operators » Electromechanical » Benchmark » LCN | Schlage Commercial » Automatic Operators » Electromechanical » Senior Swing | Schlage Commercial » Automatic Operators » Electromechanical » Senior Swing » LCN
Is there a 2021 IBC Code update on Automatic Operators on Public Entrances?
See here for informative post from Allegion IDH site on the 2021 IBC Code update on Automatic Operators on Public Entrances. See here for additional post from Allegion IDH site regarding,&n...
Schlage Commercial » Automatic Operators » Actuators » Actuators and Accessories | Schlage Commercial » Automatic Operators » Electrohydraulic | Schlage Commercial » Automatic Operators » Electrohydraulic » 4630 Series | Schlage Commercial » Automatic Operators » Electrohydraulic » 4630 Series » LCN | Schlage Commercial » Automatic Operators » Electrohydraulic » 4640 Series | Schlage Commercial » Automatic Operators » Electrohydraulic » 4640 Series » LCN | Schlage Commercial » Automatic Operators » Electromechanical | Schlage Commercial » Automatic Operators » Electromechanical » 8200 Series | Schlage Commercial » Automatic Operators » Electromechanical » 8200 Series » Falcon | Schlage Commercial » Automatic Operators » Electromechanical » Benchmark | Schlage Commercial » Automatic Operators » Electromechanical » Benchmark » LCN | Schlage Commercial » Automatic Operators » Electromechanical » Senior Swing | Schlage Commercial » Automatic Operators » Electromechanical » Senior Swing » LCN | Schlage Commercial » Automatic Operators » Pneumatics | Schlage Commercial » Automatic Operators » Pneumatics » 2610 Series | Schlage Commercial » Automatic Operators » Pneumatics » 2610 Series » LCN | Schlage Commercial » Automatic Operators » Pneumatics » 4810 Series | Schlage Commercial » Automatic Operators » Pneumatics » 4810 Series » LCN | Schlage Commercial » Automatic Operators » Pneumatics » 4820 Series | Schlage Commercial » Automatic Operators » Pneumatics » 4820 Series » LCN | Schlage Commercial » Automatic Operators » Pneumatics » 4840 Series | Schlage Commercial » Door Controls » Automatic Operator » 7980 Series | Schlage Commercial » Door Controls » Automatic Operator » 7980 Series » LCN
Can the 9100 Benchmark operator be used with the 8310-3889 safety sensor kit?
The 9100 Benchmark is not compatible with the 8310-3889 kit.  If an 8310-877 header mount safety sensor is needed with a 9100 Benchmark, follow the below wiring....
Schlage Commercial » Automatic Operators » Electromechanical | Schlage Commercial » Automatic Operators » Electromechanical » Benchmark | Schlage Commercial » Automatic Operators » Electromechanical » Benchmark » LCN
Can you convert a 8200 Falcon operator into a 9100 Benchmark by changing the controllers out?
No.  The back mounting plate between the two series are different and the Benchmark 9100 controller mounting holes will not line up with the mounting holes in the mounting plate of the Falcon 8...
Schlage Commercial » Automatic Operators » Electromechanical | Schlage Commercial » Automatic Operators » Electromechanical » 8200 Series | Schlage Commercial » Automatic Operators » Electromechanical » 8200 Series » Falcon | Schlage Commercial » Automatic Operators » Electromechanical » Benchmark | Schlage Commercial » Automatic Operators » Electromechanical » Benchmark » LCN
What is the diameter of the 155-1 caution label?
The LCN yellow caution label (155-1) is 6.5 inches in diameter.    ...
Schlage Commercial » Automatic Operators | Schlage Commercial » Automatic Operators » Sensors » Sensors and Accessories | Schlage Commercial » Automatic Operators » Electrohydraulic | Schlage Commercial » Automatic Operators » Electrohydraulic » 4630 Series | Schlage Commercial » Automatic Operators » Electrohydraulic » 4630 Series » LCN | Schlage Commercial » Automatic Operators » Electrohydraulic » 4640 Series | Schlage Commercial » Automatic Operators » Electromechanical | Schlage Commercial » Automatic Operators » Electromechanical » 8200 Series | Schlage Commercial » Automatic Operators » Electromechanical » 8200 Series » Falcon | Schlage Commercial » Automatic Operators » Electromechanical » Benchmark | Schlage Commercial » Automatic Operators » Electromechanical » Benchmark » LCN | Schlage Commercial » Automatic Operators » Electromechanical » Senior Swing | Schlage Commercial » Automatic Operators » Electromechanical » Senior Swing » LCN | Schlage Commercial » Automatic Operators » Electrohydraulic » 6440XP | Schlage Commercial » Automatic Operators » Electrohydraulic » 6400
Can you use a Benchmark Operator with a Glynn Johnson overhead stop?
It is not a recommended combination.  See below for explanation. The Benchmark Operator has an internal dead stop.   If the Benchmark Operator is installed correctly when the door...
Schlage Commercial » Automatic Operators » Electromechanical | Schlage Commercial » Automatic Operators » Electromechanical » Benchmark | Schlage Commercial » Automatic Operators » Electromechanical » Benchmark » LCN