What is the ANSI standard that the Falcon 8200 operator is designed to meet?
The Benchmark 9100 and the Falcon 8200 operator are designed to meet the ANSI BHMA A156.19 Low Energy Operator standard. ...
Schlage Commercial » Automatic Operators | Schlage Commercial » Automatic Operators » Electromechanical » 8200 Series | Schlage Commercial » Automatic Operators » Electromechanical » 8200 Series » Falcon | Schlage Commercial » Automatic Operators » Electromechanical » Benchmark
What would cause a Falcon 8200 (8230/8240) operator to slam the door closed?
The Benchmark 9100 series and Falcon 8200 Series operator will allow the door to slam if: The motor is not connected (plugged into) the controller as the closing speed is controlled by a circ...
Schlage Commercial » Automatic Operators | Schlage Commercial » Automatic Operators » Electromechanical | Schlage Commercial » Automatic Operators » Electromechanical » 8200 Series » Falcon | Schlage Commercial » Automatic Operators » Electromechanical » Benchmark | Schlage Commercial » Automatic Operators » Electromechanical » Benchmark » LCN | Schlage Commercial » Door Controls | Schlage Commercial » LCN | Schlage Commercial
Is there a manufacture date on the 9100 operator somewhere?
There is an inspection sticker placed on the Motor of the Motor/gear box assembly and also on the top of the transformer on the control box.  This inspection sticker has the manufacture date, whi...
Schlage Commercial » Automatic Operators | Schlage Commercial » Automatic Operators » Electromechanical | Schlage Commercial » Automatic Operators » Electromechanical » 8200 Series | Schlage Commercial » Automatic Operators » Electromechanical » 8200 Series » Falcon | Schlage Commercial » Automatic Operators » Electromechanical » Benchmark | Schlage Commercial » Automatic Operators » Electromechanical » Benchmark » LCN | Schlage Commercial » Door Controls | Schlage Commercial » Door Controls » Automatic Operator | Schlage Commercial » Door Controls » Automatic Operator » 8200 Series | Schlage Commercial » Door Controls » Automatic Operator » 8200 Series » LCN | Schlage Commercial » Falcon | Schlage Commercial » LCN | Schlage Commercial
Wireless activation button will not open door on the 8310-865.
Common problems in new installation: Line of sight between transmitter and receiver OR programming the transmitter to the receiver. Fix line of sight by relocating transmitter, receiver or both. Fix p...
Schlage Commercial » Automatic Operators » Actuators » Actuators and Accessories | Schlage Commercial » Automatic Operators » Electrohydraulic | Schlage Commercial » Automatic Operators » Electrohydraulic » 4630 Series | Schlage Commercial » Automatic Operators » Electrohydraulic » 4640 Series | Schlage Commercial » Automatic Operators » Electromechanical » 8200 Series | Schlage Commercial » Automatic Operators » Electromechanical » Benchmark | Schlage Commercial » Automatic Operators » Electromechanical » Senior Swing | Schlage Commercial » Automatic Operators » Pneumatics » 2610 Series | Schlage Commercial » Automatic Operators » Pneumatics » 2610 Series » LCN | Schlage Commercial » Automatic Operators » Pneumatics » 4810 Series | Schlage Commercial » Automatic Operators » Pneumatics » 4820 Series | Schlage Commercial » Automatic Operators » Pneumatics » 4820 Series » LCN | Schlage Commercial » Automatic Operators » Pneumatics » 4840 Series | Schlage Commercial » Falcon | Schlage Commercial » LCN
My push button actuator works intermittently.
The switch could be wearing out from fatigue and may need to be replaced, but it may be worth troubleshooting the following: The push plate may have shifted in its mounting box, not allowing for ...
Schlage Commercial » Automatic Operators | Schlage Commercial » Automatic Operators » Actuators | Schlage Commercial » Automatic Operators » Actuators » Actuators and Accessories | Schlage Commercial » Automatic Operators » Actuators » Actuators and Accessories » LCN | Schlage Commercial » Automatic Operators » Electrohydraulic | Schlage Commercial » Automatic Operators » Electrohydraulic » 4630 Series | Schlage Commercial » Automatic Operators » Electrohydraulic » 4640 Series | Schlage Commercial » Automatic Operators » Electromechanical | Schlage Commercial » Automatic Operators » Electromechanical » 8200 Series | Schlage Commercial » Automatic Operators » Electromechanical » Benchmark | Schlage Commercial » Automatic Operators » Electromechanical » Senior Swing | Schlage Commercial » Automatic Operators » Pneumatics
Can you order an LCN Closer without a finish?
No, all LCN and Falcon closers are shipped with an approved finish.  ...
Schlage Commercial » Automatic Operators | Schlage Commercial » Automatic Operators » Electrohydraulic | Schlage Commercial » Automatic Operators » Electrohydraulic » 4630 Series | Schlage Commercial » Automatic Operators » Electrohydraulic » 4640 Series | Schlage Commercial » Automatic Operators » Electromechanical | Schlage Commercial » Automatic Operators » Electromechanical » 8200 Series | Schlage Commercial » Automatic Operators » Electromechanical » Benchmark | Schlage Commercial » Automatic Operators » Electromechanical » Senior Swing | Schlage Commercial » Automatic Operators » Pneumatics | Schlage Commercial » Automatic Operators » Pneumatics » 2610 Series | Schlage Commercial » Automatic Operators » Pneumatics » 4810 Series | Schlage Commercial » Automatic Operators » Pneumatics » 4820 Series | Schlage Commercial » Automatic Operators » Pneumatics » 4840 Series | Schlage Commercial » Door Controls | Schlage Commercial » Door Controls » Overhead Concealed | Schlage Commercial » Door Controls » Overhead Concealed » 2010 Series | Schlage Commercial » Door Controls » Overhead Concealed » 2030 Series | Schlage Commercial » Door Controls » Automatic Operator | Schlage Commercial » Door Controls » Automatic Operator » 8200 Series | Schlage Commercial » Door Controls » Concealed | Schlage Commercial » Door Controls » Concealed » OHC100 Series | Schlage Commercial » Door Controls » Concealed » 3030 Series | Schlage Commercial » Door Controls » Concealed » 3130 Series | Schlage Commercial » Door Controls » Concealed » 330 Series | Schlage Commercial » Door Controls » Concealed » 5030 Series | Schlage Commercial » Door Controls » Concealed » 6030 Series | Schlage Commercial » Door Controls » Fire Life Safety | Schlage Commercial » Door Controls » Fire Life Safety » Multi Point Hold Open Closer | Schlage Commercial » Door Controls » Fire Life Safety » SEH Series | Schlage Commercial » Door Controls » Fire Life Safety » SEM 1900 Series Magnets | Schlage Commercial » Door Controls » Fire Life Safety » SEM 7800 Series Magnets | Schlage Commercial » Door Controls » Fire Life Safety » Single Point Hold Open Closer | Schlage Commercial » Door Controls » Fire Life Safety » Fire/Life Safety Series | Schlage Commercial » Door Controls » Fire Life Safety » SEM Series | Schlage Commercial » Door Controls » High Security | Schlage Commercial » Door Controls » High Security » 2210 Series | Schlage Commercial » Door Controls » High Security » 4210 Series | Schlage Commercial » Door Controls » High Security » 4510 Series | Schlage Commercial » Door Controls » Overhead Concealed » 5010 Series | Schlage Commercial » Door Controls » Overhead Concealed » 6030 Series | Schlage Commercial » Door Controls » Overhead Concealed » OHC 100 Series | Schlage Commercial » Door Controls » Surface Mounted | Schlage Commercial » Door Controls » Surface Mounted » 1000 Series | Schlage Commercial » Door Controls » Surface Mounted » 1040 Series | Schlage Commercial » Door Controls » Surface Mounted » 1050 Series | Schlage Commercial » Door Controls » Surface Mounted » 1070 Series | Schlage Commercial » Door Controls » Surface Mounted » 1260 Series | Schlage Commercial » Door Controls » Surface Mounted » 1460 Series | Schlage Commercial » Door Controls » Surface Mounted » 4010 Series | Schlage Commercial » Door Controls » Surface Mounted » 4020 Series | Schlage Commercial » Door Controls » Surface Mounted » 4030 Series | Schlage Commercial » Door Controls » Surface Mounted » 4040 Series | Schlage Commercial » Door Controls » Surface Mounted » 4040XP Series | Schlage Commercial » Door Controls » Surface Mounted » 4110 Series | Schlage Commercial » Door Controls » Surface Mounted » 4130 Series | Schlage Commercial » Door Controls » Surface Mounted » SC60 Series | Schlage Commercial » Door Controls » Surface Mounted » SC70 Series | Schlage Commercial » Door Controls » Surface Mounted » SC80 Series | Schlage Commercial » Door Controls » Surface Mounted » SC90 Series | Schlage Commercial » Door Controls » Surface Mounted » 4000 Series | Schlage Commercial | Schlage Commercial » Door Controls » Surface Mounted » 1250 Series | Schlage Commercial » Door Controls » Surface Mounted » 1450 Series | Schlage Commercial » Door Controls » Surface Mounted » 1450T Series | Schlage Commercial » Door Controls » Surface Mounted » 4050 Series | Schlage Commercial » Door Controls » Surface Mounted » 4050T Series
Is the 9100 series Benchmark operator UL listed for fire doors?
Schlage Commercial » Automatic Operators | Schlage Commercial » Automatic Operators » Electromechanical | Schlage Commercial » Automatic Operators » Electromechanical » 8200 Series | Schlage Commercial » Automatic Operators » Electromechanical » Benchmark | Schlage Commercial » Door Controls | Schlage Commercial » Door Controls » Automatic Operator | Schlage Commercial » LCN | Schlage Commercial
When the Benchmark Operator is in the Hold open position, what is the holding voltage on the motor?
Approximately 5 volts....
Schlage Commercial » Automatic Operators | Schlage Commercial » Automatic Operators » Electromechanical | Schlage Commercial » Automatic Operators » Electromechanical » Benchmark | Schlage Commercial » Automatic Operators » Electromechanical » Benchmark » LCN | Schlage Commercial » Door Controls | Schlage Commercial » Door Controls » Automatic Operator | Schlage Commercial » LCN | Schlage Commercial
When were the benchmark (9130/9140/9150) adapter harnesses -3428-1, -3598, -3430 cables made obsolete?
April 4th of 2008....
Schlage Commercial » Automatic Operators | Schlage Commercial » Automatic Operators » Electromechanical | Schlage Commercial » Automatic Operators » Electromechanical » Benchmark | Schlage Commercial » Automatic Operators » Electromechanical » Benchmark » LCN | Schlage Commercial » Door Controls | Schlage Commercial » Door Controls » Automatic Operator | Schlage Commercial » LCN | Schlage Commercial
Where should the "Automatic Caution Door" labels be applied on a door with a low energy operator?
The caution sign needs to be visible from both sides of door.  Mounted 50" +/- 12" from floor to center of sign....
Schlage Commercial » Automatic Operators | Schlage Commercial » Automatic Operators » Electrohydraulic | Schlage Commercial » Automatic Operators » Electrohydraulic » 4630 Series | Schlage Commercial » Automatic Operators » Electrohydraulic » 4640 Series | Schlage Commercial » Automatic Operators » Electromechanical | Schlage Commercial » Automatic Operators » Electromechanical » 8200 Series | Schlage Commercial » Automatic Operators » Electromechanical » Benchmark | Schlage Commercial » Automatic Operators » Electromechanical » Senior Swing | Schlage Commercial » Automatic Operators » Pneumatics | Schlage Commercial » Automatic Operators » Pneumatics » 2610 Series | Schlage Commercial » Automatic Operators » Pneumatics » 4810 Series | Schlage Commercial » Automatic Operators » Pneumatics » 4820 Series | Schlage Commercial » Automatic Operators » Pneumatics » 4840 Series | Schlage Commercial » LCN | Schlage Commercial