Where do you find demo mode on a PIM-400?
You must sign in as a manager in the SUS app. and you will see Demo Mode on the main menu. ...
Schlage Commercial » Electronic Locks » Networked » AD 400 Series | Schlage Commercial » Electronic Locks » PIM400
In the PIM 400 485 and TD2 models there is a "reader tab" which gives you options to enable or disable card reads. Can you make changes to these settings in the PIM and have them reflect to the AD-400 lockset?
You can change reader setting through the PIM on a linked lock, however it is not recommended because it could take up to 10 minutes for the lock to see the change. We always recommend making any chan...
Schlage Commercial » Electronic Locks » Networked » AD 400 Series | Schlage Commercial » Electronic Locks » PIM400
Can you emulate apartment mode in demo mode?
You cannot emulate apartment mode in Demo mode, that function is only controlled by an access control panel.  All you would be able to do is see if a credential presentation unlocks the door and ...
Schlage Commercial » Electronic Locks » Networked » AD 400 Series | Schlage Commercial » Electronic Locks » PIM400
Can a PIM400-485 and a PIM400-TD2 both enable an IPB inside push button on an AD400?
The PIM400-485 will support the function of the inside pushbutton (IPB), however the PIM400-TD2 will not....