Zentra - What Devices Are Supported?
The Schlage/Isonas devices supported by Zentra Living (as of March 2024):Schlage Control (BE467 and FE410)Schlage RC Reader Controller (RC11, RC15, RCK15)Devices Coming to Zentra Living:Schlage NDE-se...
Schlage Commercial » Electronic Locks » NDE Series | Schlage Commercial » Electronic Locks » LE Series | Schlage Commercial » Electronic Locks » CTE | Schlage Commercial » Multi-Family » FE410 | Schlage Commercial » Multi-Family » BE467 | Schlage Commercial » Software » Isonas » RC-04 | Schlage Commercial » Software » Isonas » IPBridge | Schlage Commercial » Software » Isonas » RC Reader Controller | Schlage Commercial » Software » Zentra
What is the difference between the RC-04-PRX-M and the R-1-MCT-M?
Both the MCT and the PRX models will read 125KHz proximity credentials, but the MCT also reads the13.56MHz smart cards. The MCT model will not read the secure sector data on non-Isonas smart cred...
Schlage Commercial » Software » Isonas » Pure Access Cloud | Schlage Commercial » Software » Isonas » RC-04
What does ‘Device Disconnect’ and ‘Device Connect’ events mean in Pure Access Cloud?
‘Device Disconnect’ and ‘Device Connect’ events are normal in Pure Access Cloud as long as the disconnect lasts approximately 15-30 seconds. These can be caused by Pure Access Cloud updates or...
Schlage Commercial » Software » Isonas » Pure Access Cloud | Schlage Commercial » Software » Isonas » RC-04 | Schlage Commercial » Software » Isonas » RC-03 | Schlage Commercial » Software » Isonas » IPBridge | Schlage Commercial » Software » Isonas » RC Reader Controller
How are pin codes entered in Pure Access Cloud?
A PIN code must be entered as follows:“*”, PIN and then “#”...
Schlage Commercial » Software » Isonas » Pure Access Manager | Schlage Commercial » Software » Isonas » Pure Access Cloud | Schlage Commercial » Software » Isonas » RC-04 | Schlage Commercial » Software » Isonas » RC-03 | Schlage Commercial » Software » Isonas » IPBridge | Schlage Commercial » Software » Isonas » RC Reader Controller
Pure Access Cloud toggle function
For Isonas devices, toggle is a host-based feature. Therefore, the device the credential is presented at must have an active connection to the Pure Access Cloud server for the toggl...
Schlage Commercial » Software » Isonas » Pure Access Cloud | Schlage Commercial » Software » Isonas » RC-04 | Schlage Commercial » Software » Isonas » IPBridge | Schlage Commercial » Software » Isonas » RC Reader Controller
Will electric strike locking device work with an RC04 over PoE?
The RC04 can supply a total of 600mA at 12VDC to external devices. This is a total for ALL devices being powered by the RC04; locking devices and other devices such as ASM Modules or PIR REX Mot...
Schlage Commercial » Software » Isonas » Pure Access Cloud | Schlage Commercial » Software » Isonas » RC-04