Will the 4040XP drop plates work with the 6440XP operator?
Physically, yes they will work since the closer body is a 4040XP BUT the 4040XP drop plates are not large enough to match up with the larger 6440XP cover.It is always best to use the 6440XP Drop Plate...
Schlage Commercial » Automatic Operators | Schlage Commercial » Door Controls » Surface Mounted » 4040 Series | Schlage Commercial » Door Controls » Surface Mounted » 4040XP Series | Schlage Commercial » Automatic Operators » Electrohydraulic » 6440XP
What cycle testing has the 6440XP been tested too?
The 6440XP operator is certified to ANSI 156.19 low energy operator standard, which contains cycle testing to 300,000 cycles....
Schlage Commercial » Automatic Operators | Schlage Commercial » Automatic Operators » Electrohydraulic » 6440XP
How does LCN Recommend setting up the 6440 for use with the SOLA battery back up?
When using the SOLA uninterruptible power supply with the 6440XP, it is recommended the 120VAC output from the SOLA is wired directly to a wall outlet, and then the plug in Transformer provided with t...
Schlage Commercial » Automatic Operators | Schlage Commercial » Automatic Operators » Electrohydraulic » 6440XP
Why will my 6440XP not open after a power cycle?
The 6440 will attempt a learning cycle if it has recently experienced a power loss. During this cycle, the L speed LED will be Blinking Blue, and the door will open slowly to check for obstr...
Schlage Commercial » Automatic Operators | Schlage Commercial » Automatic Operators » Electrohydraulic » 6440XP
Does LCN offer drop plates for the 6440XP operator?
LCN does offer drop plates for the 6440XP, as follows:6440-18TJ (Top Jamb)6440-18 (Standard Pull Side)6440-18PA (Parallel)...
Schlage Commercial » Automatic Operators | Schlage Commercial » Automatic Operators » Electrohydraulic » 6440XP | Schlage Commercial » Automatic Operators » Electrohydraulic » 6400
How would you connect hardwired actuators to the 6440XP?
From the hardwired actuators- connect Common to pin 4 and Normally Open to pin 5 on 6440XP terminal....
Schlage Commercial » Automatic Operators | Schlage Commercial » Automatic Operators » Electrohydraulic » 6440XP | Schlage Commercial » Automatic Operators » Electrohydraulic » 6400
Can you use the 8310-806K(R) three position switch with the 6440XP?
The 8310-806K and 8310-806R switches will not work with the 6400 Compact Operator.  This unit does not have an indefinite hold open feature, nor will it hold open indefinitely if you send a const...
Schlage Commercial » Automatic Operators | Schlage Commercial » Door Controls » Automatic Operator » 8310 Series | Schlage Commercial » Automatic Operators » Electrohydraulic » 6440XP | Schlage Commercial » Automatic Operators » Electrohydraulic » 6400