For delayed egress products greater than 15 seconds, who grants approval and who needs proof of the approval?
The IBC says, “Where approved, a delay of not more than 30 seconds is permitted on a delayed egress door.”  Over 15 second delay requires approval (not necessarily a letter) from the aut...
Schlage Commercial » Building Code
Is the Falcon F-25-C device hurricane rated?
The F-25-C (fire rated version only) device is hurricane impact rated.  Reference Florida Building Code FL12400.     See this article for more information: &nbs...
Schlage Commercial » Exit Devices | Schlage Commercial » Exit Devices » Touch Bar » 25 Series » Falcon | Schlage Commercial » Building Code
Are Ives hinges UL fire listed, and do they bear a UL fire label marking?
UL labeling is required for spring hinges and for continuous hinges when used in fire rated assemblies.  UL labeling is not required for pivots or standard butt hinges used in fire rated assembli...
Schlage Commercial » Ives | Schlage Commercial » Building Code
Can the M996L trim be used with the 2SI option?
Yes, the M996L trim can be used with the 2SI (security indicator) option. NOTE:  In the case that M996L is set for fail safe, the 2SI option can mechanically lock the trim and prevent ingr...
Schlage Commercial » Exit Devices » Touch Bar » 98/99 Series » Von Duprin | Schlage Commercial » Building Code
Does the 385A strike meet ADA standards?
Accessibility standards note 0.5" diameter max allowable openings in floor surfaces. The 385A does require a larger opening for the strike to work with the devices as tested for proper operation...