What is the LCN 8310-852TA actuator?
On March 27, 2019, LCN came out with a 8310-852TA actuator, which is a 6" round actuator with the Active Wheelchair logo and text. ...
Schlage Commercial » Automatic Operators | Schlage Commercial » Automatic Operators » Actuators | Schlage Commercial » Automatic Operators » Actuators » Actuators and Accessories | Schlage Commercial » Automatic Operators » Actuators » Actuators and Accessories » LCN | Schlage Commercial » Door Controls | Schlage Commercial » Door Controls » Automatic Operator | Schlage Commercial » Door Controls » Automatic Operator » 8310 Series | Schlage Commercial » Door Controls » Automatic Operator » 8310 Series » LCN | Schlage Commercial » LCN | Schlage Commercial
When did LCN change the 4600 mounting plate?
On March 19, 2019- the 4600 mounting channel/plate changed from Alum to steel (black). This also eliminated the need for the cylinder standoffs....
Schlage Commercial » Automatic Operators | Schlage Commercial » Automatic Operators » Electrohydraulic | Schlage Commercial » Automatic Operators » Electrohydraulic » 4630 Series | Schlage Commercial » Automatic Operators » Electrohydraulic » 4630 Series » LCN | Schlage Commercial » Automatic Operators » Electrohydraulic » 4640 Series | Schlage Commercial » Automatic Operators » Electrohydraulic » 4640 Series » LCN | Schlage Commercial » Door Controls | Schlage Commercial » Door Controls » Automatic Operator | Schlage Commercial » LCN | Schlage Commercial
What is comparable to a Sargent 7000 series?
The Von Duprin 237Lx378LThis unit is a lever by lever with concealed vertical rods. ...
Schlage Commercial » Exit Devices | Schlage Commercial » Exit Devices » Mechanical Accessories | Schlage Commercial
What is the difference between the 471U, the 472U, and 473U strikes?
The 471U is for a 5547 with a metal door and frame.The 472U is for a 5547WDC with a wood frame and a 1-3/4" thick door. The 473U is for a 5547WDC with a wood frame and a 2-1/4" thick door. ...
Schlage Commercial » Exit Devices | Schlage Commercial » Exit Devices » Cross Bar | Schlage Commercial » Exit Devices » Cross Bar » 55 Series | Schlage Commercial » Exit Devices » Cross Bar » 55 Series » Von Duprin | Schlage Commercial » Exit Devices » Mechanical Accessories | Schlage Commercial » Von Duprin | Schlage Commercial
What do I need to specify when ordering the -12 Sr Swing filler plate?
Length of header and
spindle center. This information is needed so the length and mounting holes in filler plate will match the original operator.For any filler plate that requires a Stop Cut out...
Schlage Commercial » Automatic Operators | Schlage Commercial » Automatic Operators » Electromechanical | Schlage Commercial » Automatic Operators » Electromechanical » Senior Swing | Schlage Commercial » Automatic Operators » Electromechanical » Senior Swing » LCN | Schlage Commercial » Door Controls | Schlage Commercial » Door Controls » Automatic Operator | Schlage Commercial » LCN | Schlage Commercial
Are the SC60A-18 and SC90A-18 drop plates the same?
Yes, these plates have the same mounting hole dimensions and the cylinders (SC61A, SC93A, and SC94A) have the same hole pattern of 3/4" X 9 1/16".Please Note: The plates are the same but th...
Schlage Commercial » Door Controls | Schlage Commercial » Door Controls » Surface Mounted | Schlage Commercial » Door Controls » Surface Mounted » SC60 Series | Schlage Commercial » Door Controls » Surface Mounted » SC60 Series » Falcon | Schlage Commercial » Door Controls » Surface Mounted » SC90 Series | Schlage Commercial » Door Controls » Surface Mounted » SC90 Series » Falcon | Schlage Commercial » Falcon | Schlage Commercial
Is the LCN 8310-813 touchless actuator a NEMA 4 certified actuator?
No, The LCN offering of a 8310-813 touchless actuator is not NEMA 4 certified....
Schlage Commercial » Automatic Operators | Schlage Commercial » Automatic Operators » Actuators | Schlage Commercial » Automatic Operators » Actuators » Actuators and Accessories | Schlage Commercial » Automatic Operators » Actuators » Actuators and Accessories » LCN | Schlage Commercial » Door Controls | Schlage Commercial » Door Controls » Automatic Operator | Schlage Commercial » Door Controls » Automatic Operator » 8310 Series | Schlage Commercial » Door Controls » Automatic Operator » 8310 Series » LCN | Schlage Commercial
How can you identify if an OHC100 cylinder is a 90 degree or a 105 degree?
The degree of opening of the cylinder is stamped on the end of the pinion/cylinder shaft (where the arm attaches to closer). ...
Schlage Commercial » Door Controls | Schlage Commercial » Door Controls » Concealed | Schlage Commercial » Door Controls » Concealed » OHC100 Series | Schlage Commercial » Door Controls » Concealed » OHC100 Series » Falcon | Schlage Commercial » Falcon | Schlage Commercial