What is the recommended wiring for a Gateway?
Wiring for the Gateway:DC terminal input: 18AWG, 2 conductor (Belden 8760 or equivalent) up to 1000 ft (305 m)Gateway to ACP: 24AWG, 2 or 4 conductor shielded (Belden 9842,9841 or equivalent) up to 40...
Schlage Commercial » Electronic Locks » Gateway
How can I downgrade firmware on an Engage device?
NDEB, LEB, MT20W and Control locks are able to be downgraded to an earlier version of the firmware.Some devices, once they have the most recent updated firmware, you are unable to downgrade ...
Schlage Commercial » Electronic Locks | Schlage Commercial » Electronic Locks » NDE Series | Schlage Commercial » Electronic Locks » Gateway | Schlage Commercial » Electronic Locks » LE Series | Schlage Commercial » Electronic Locks » CTE
Why would you use a gateway with PIM 400 485 and AD 400 Locksets?
As long as they are using RSI mode, (using either 2- or 4-wire RS-485 connections) then yes, they can daisy chain PIM400-485 and gateways in the same chain. Just make sure the PIMs and gateway's addre...