What does the 3H mean on a Falcon B or Falcon H lock?
The 3H stamped into the face plate of the Falcon B and Falcon H lock means 3-hour fire rated. ...
Schlage Commercial » Falcon
Are there results or ratings of a salt spray test on a 25 series?
The device must meet minimum of 100 hrs., standards:  ASTM  B117Falcon organic finishes (powder-coat, e-coat, etc.) are only certified to 96 hours.  Falcon inorganic finishes such as ch...
Schlage Commercial » Falcon
What type of cylinder does a Falcon 812L trim use?
A rim cylinder is required for rim and vertical rod XX devices.  A mortise cylinder is required for a mortise lock XX device....
Schlage Commercial » Exit Devices | Schlage Commercial » Falcon
For an older 18 R Apollo NL trim, what would I use to replace with current product?
You could use:Falcon: 25 R 512NL,  or Von Duprin: 98NL 990....
Schlage Commercial » Exit Devices | Schlage Commercial » Falcon | Schlage Commercial » Von Duprin
Is the Falcon 25V exit device handed?
The device is handed but field reversible as shown here in step 11 of the installation instructions....
Schlage Commercial » Exit Devices | Schlage Commercial » Falcon
Does the 2' 9927-F come with a fire lable?
Yes...
Schlage Commercial » Exit Devices | Schlage Commercial » Falcon
Will the F-25-R work for a 9' tall door? The catalog says only good to 8'.
8' max  height on UL fire rated F-25-R...
Schlage Commercial » Exit Devices | Schlage Commercial » Falcon
Is the LM or DM switch for the 25 series available as a field installable kit?
For the 25 series, the LM or DM kit is field replaceable, but not field installable.  There are 2 holes that must be drilled in the center case at the factory for those switch kits....
Schlage Commercial » Exit Devices | Schlage Commercial » Falcon
Can the Falcon 510L FSA/FSE be converted in the field?
Yes.  The Falcon 510L FSA/FSE be converted in the field?Click Here for details. ...
Schlage Commercial » Exit Devices | Schlage Commercial » Falcon
How many changes are available in a SFIC master key system?
Depends on the combinating rule and the number of pins (chambers).   For A2  6 pin systems = 4,096 changes For A2 7 pin systems = 16,384 changes   For A4 6 pin systems = 15,625 cha...
Schlage Commercial » Key Systems » Cylinders | Schlage Commercial » Key Systems » Keys | Schlage Commercial » Falcon | Schlage Commercial » Schlage