Category: Falcon

(Results from 61 to 70)
Will the F-25-R work for a 9' tall door? The catalog says only good to 8'.
8' max  height on UL fire rated F-25-R...
Schlage Commercial » Exit Devices | Schlage Commercial » Falcon
Is the LM or DM switch for the 25 series available as a field installable kit?
For the 25 series, the LM or DM kit is field replaceable, but not field installable.  There are 2 holes that must be drilled in the center case at the factory for those switch kits....
Schlage Commercial » Exit Devices | Schlage Commercial » Falcon
Can the Falcon 510L FSA/FSE be converted in the field?
Yes.  The Falcon 510L FSA/FSE be converted in the field?Click Here for details. ...
Schlage Commercial » Exit Devices | Schlage Commercial » Falcon
Are the Falcon C261 and C264 cylinders still available?
The C261 and C264 are no longer offered. The C262 RH 1-5/8" can be used in place of C261 RH 1-1/2".The C265 LH 1-5/8" in place of the C264 LH  1-1/2"...
Schlage Commercial » Key Systems » Cylinders » Cylinder | Schlage Commercial » Key Systems » Cylinders » Cylinder » Falcon | Schlage Commercial » Falcon
What Allegion components are ITS/WHI Intertek approved for Windstorm/Tornado Resistant openings?
The Steelcraft Paladin Series doors and frames are available in compliance with FEMA 361 and ANSI ICC500-2014.  The door system may include other approved Allegion hardware and components that ar...
Schlage Commercial » Automatic Operators | Schlage Commercial » Doors and Frames | Schlage Commercial » Exit Devices | Schlage Commercial » Mechanical Accessories | Schlage Commercial » Mechanical Locks | Schlage Commercial » Falcon | Schlage Commercial » Glynn-Johnson | Schlage Commercial » Ives | Schlage Commercial » LCN | Schlage Commercial » Steelcraft | Schlage Commercial » Von Duprin | Schlage Commercial » Zero | Schlage Commercial » Sealing Systems
Can fire rated exit devices have electric latch retraction?
Yes, fire rated exit devices can have electric latch retraction.  However, the devices must be tied into a fire alarm system to remove power from the units so the doors will be latched in the cas...
Schlage Commercial » Exit Devices | Schlage Commercial » Exit Devices » Touch Bar | Schlage Commercial » Falcon | Schlage Commercial » Von Duprin
Is it possible to convert a Falcon EL device to an MEL device?
The answer to this question depends on which Falcon EL device is involved.The Falcon 24 and 25 Series Devices with the EL option CAN NOT be converted to MEL in the field.The 24/25 Series MEL Conversio...
Schlage Commercial » Exit Devices | Schlage Commercial » Falcon
What power supply is required for the Falcon MEL device?
For simple card reader (access control) applications, the PS902 x 900-2RS can power up to 2 MEL devices.  The MEL device has a 1 amp inrush, with .14 amp holding current requirement.  For mo...
Schlage Commercial » Exit Devices | Schlage Commercial » Falcon
How is the Falcon 9970 pull trim mounted?
The pull is furnished with shoulder bolts and set screws that affix the trim to the pull side of the door.  The trim does not through bolt to the door....
Schlage Commercial » Falcon
Why is the Falcon motorized electric latch retraction device called MEL instead of QEL (Quiet Electric Latch)?
This option is being marketed as a power efficiency improvement over the current solenoid latch retraction product (1 amp in-rush of the motor vs. 16 amp in-rush of the solenoid). Falcon 24/25 exit de...
Schlage Commercial » Falcon