What is the voltage or power limit of an EPT device (EPT2 or EPT10)
The UL panic hardware file SA163
supports the installation instructions electrical ratings of
·
EPT2
o 24VDC, 5A or
o 120VAC on...
Schlage Commercial » System Components » Power Supplies » EPT Series | Schlage Commercial » System Components » Power Supplies » EPT Series » Von Duprin
Can the Von Duprin EPT be used on a wood door?
The EPT-2 and the EPT-10 can be used on aluminum, hollow metal, and wood doors. It is recommended that the door manufacturer be consulted as well for compliance in UL applications....
Schlage Commercial » System Components » Power Supplies » EPT Series » Von Duprin
Is EPT-10 rated for UL10C?
Yes. This is not explicitly shown in the UL Product IQ database.
Per Allegion compliance team, file R15551 explicitly shows EPT-10 as UL10C.
...
Schlage Commercial » System Components » Power Supplies » EPT Series » Von Duprin
What is EPT10C?
EPT10C and the devices that go with it are "engineering special" products. They are for San Francisco Airport only. They have unique connectors. They are not compatible with Allegion...
Schlage Commercial » System Components » Power Supplies » EPT Series | Schlage Commercial » System Components » Power Supplies » EPT Series » Von Duprin
What are the electrical ratings for the EPT power transfer?
The UL panic hardware file SA163 supports electrical ratings of:
EPT2
24VDC, 5A
120VAC on NEC Class 3 circuit
Non-fire rated applications
EPT10
24VDC, 1A
&n...
Schlage Commercial » System Components » Power Supplies » EPT Series | Schlage Commercial » System Components » Power Supplies » EPT Series » Von Duprin
Can you use Cam Lift Hinges with Von Duprin EPT
The Von Duprin EPT-2, EPT-10, and PNT-1 will work with cam lift hinges with a maximum lift of 1/4". Depending on opening conditions, the door can open to 180° without binding or stress....
Schlage Commercial » Mechanical Accessories » Hinges & Pivots » Ives | Schlage Commercial » System Components » Power Supplies » EPT Series » Von Duprin
Can you use an EPT10 power transfer with AD300 Lockset?
You can use an EPT10 with an AD300 lock. It should be better than an electrified hinge to avoid wire breakage.
...
Schlage Commercial » Electronic Locks | Schlage Commercial » Electronic Locks » Networked » AD 300 Series | Schlage Commercial » System Components » Power Supplies » EPT Series | Schlage Commercial » System Components » Power Supplies » EPT Series » Von Duprin