Where is factory recommendation for location of an EPT?
EPT installation guidelines are as follows:
Recommended location is 6" below top hinge per template
Steelcraft will locate the power transfer prep at the Von Duprin recom...
Schlage Commercial » System Components » Power Supplies » EPT Series » Von Duprin
Where is common cutout for Von Duprin EPT prep in Ives 224 Continuous Hinge?
Cutout depends on the size of 224 hinge. See 112HD/224HD-EPT template.
112HD/224HD continuous hinge
Center line of EPT to top of the door
83 inches
30 inches
85 inches
32...
Schlage Commercial » Mechanical Accessories » Hinges & Pivots » Ives | Schlage Commercial » System Components » Power Supplies » EPT Series » Von Duprin
Does the wire size of an EPT affect the operation of an EL device?
Since most wire transfer devices such as an EPT or electric hinges cannot provide large gauge wires, we take the small gauge wire into account when determining the overall wire size for the device.�...
Schlage Commercial » Exit Devices » Recessed » 2390 Series » Falcon | Schlage Commercial » Exit Devices » Recessed » 94/95 Series INPACT » Von Duprin | Schlage Commercial » Exit Devices » Touch Bar » 1490 Series » Falcon | Schlage Commercial » Exit Devices » Touch Bar » 1590 Series » Falcon | Schlage Commercial » Exit Devices » Touch Bar » 1690 Series » Falcon | Schlage Commercial » Exit Devices » Touch Bar » 1790 Series » Falcon | Schlage Commercial » Exit Devices » Touch Bar » 24 Series » Falcon | Schlage Commercial » Exit Devices » Touch Bar » 25 Series » Falcon | Schlage Commercial » Exit Devices » Touch Bar » 33A/35A Series » Von Duprin | Schlage Commercial » Exit Devices » Touch Bar » 98/99 Series » Von Duprin | Schlage Commercial » System Components » Power Supplies » EPT Series » Von Duprin
Should the EPT-2 or EPT-10 be used on an EL device?
Either EPT product will work fine for the EL.If you ever anticipate to add any additional electrical options such as RX or LX switches or electrified trim you may want to use the EPT10....
Schlage Commercial » System Components » Power Supplies » EPT Series » Von Duprin
What is the difference between the EPT 2 and the EPT 10?:
The EPT2 has (2) 18 gauge wires and the EPT10 has (10) 24 gauge wires.
Even though they are 18 gauge or 24 gauge wires they are special high stress, high flex, & high current wires specifically u...
Schlage Commercial » System Components » Power Supplies » EPT Series » Von Duprin