Category: Schlage Electronics

(Results from 1 to 9)
Switch_Relay Nomenclature
Normally-open (NO) contacts connect the circuit when the relay is activated; the circuit is disconnected when the relay is inactive. It is also called a Form A contact or "make" contact. Normally-...
Schlage Commercial » System Components » Door Position Switch » 7700 Series » Schlage Electronics | Schlage Commercial » System Components » System Accessories » Request to Exit Devices » Schlage Electronics
What type of switch is in the 701RD
701RD is a  SPDT contact set:  normally open, common, normally closed...
Schlage Commercial » System Components » System Accessories » Request to Exit Devices » Schlage Electronics
is the 600 series pushbutton compatibale with DA and DPDT
No - these options are mutally exclusive  the delayed action versions have a different sub assembly and can’t Be added  or modified....
Schlage Commercial » System Components » System Accessories » Request to Exit Devices » Schlage Electronics
what does DA mean on pushbuttons
DA - delayed action - once activated holds contsct state for delay time...
Schlage Commercial » System Components » System Accessories » Request to Exit Devices » Schlage Electronics
660 Series Surface Mini Box electrical
Cut sheet and price book show the below we do not recommend these specs SpecificationsSwitch contact rating 6 amp @ 120 VAC...
Schlage Commercial » System Components » System Accessories » Request to Exit Devices » Schlage Electronics
620 Pushbutton datasheet
See attached documentwww.schlage.com/support Choose System components Electromagnetic Locks ...
Schlage Commercial » System Components » System Accessories » Request to Exit Devices » Schlage Electronics
What is the part # for the Green or Red LED for 700 Series Pushbutton?
Link to Download the 701/709 Replacement Parts GuideLink to Download the Sales Cutsheet  700 Series Pushbuttons (ES5976)...
Schlage Commercial » System Components » System Accessories » Request to Exit Devices » Schlage Electronics
Would the 660-T4 or 660-PB mini station work with any elecrified panic exit device?
The 660-T4 or 660-PB is just a dry contact momentary or toggle switch. As long as the voltage and current that is being passed through the switch does not exceed the switch rating, it should be a vali...
Schlage Commercial » System Components » Powerbolt » 400 Series » Schlage Electronics | Schlage Commercial » System Components » System Accessories » Request to Exit Devices » Schlage Electronics
RU/RM incomplete LINK
RU & RM will not fully LINK to a Gateway (GWE) if the communication bus of the RU/RM mainboard to the DPS module is defective. With the DPS COM fault, the LINK symptom after OK LINKING ...
Schlage Commercial » Exit Devices | Schlage Commercial » System Components » System Accessories » Request to Exit Devices | Schlage Commercial » System Components » System Accessories » Request to Exit Devices » Schlage Electronics