No DC output from Power Supply
If a power supply is not outputting DC power, 12 or 24VDC at the Power supply main board lower right terminals ( DC+ DC-), there are several potential causes.
· &nbs...
Schlage Commercial » System Components » Power Supplies » PS900 Series » Schlage Electronics
What is the function of Green cable on PS902
Those are internal communication lines used between the 900-4RL(s) and 900-2Q(s) boards in whatever combination they are arranged in. They go straight through the power supply board. It is only used a...
Schlage Commercial » System Components » Power Supplies » PS900 Series » Schlage Electronics
What power supply do I use with an L9000 electrified L lock?
Applies to L9080EL/EU, L9082EL/EU (Discontinued) The Schlage L9080 EU/EL and L9082 EU/EL require 24 VAC/VDC with a peak current of 1.3 Amps at 5 to 10 second intervals and a holding cur...
Schlage Commercial » Mechanical Locks » Mortised » L9000 Series | Schlage Commercial » Mechanical Locks » Mortised » L9000 Series » Schlage | Schlage Commercial » Mechanical Locks » Mortised » LV9000-Series | Schlage Commercial » Mechanical Locks » Mortised » LV9000-Series » Schlage | Schlage Commercial » System Components » Power Supplies » PS900 Series » Schlage Electronics
Does the 900-BBK option for the PS900 series recharge the batteries?
Yes, the 900-BBK is a kit that contains the battery backup circuit board and (2) 12V 7 amp/hour batteries which will provide battery back up to the unit when AC fails and will also charge the batter...
Schlage Commercial » System Components » Power Supplies » PS900 Series » Schlage Electronics
What is the 6200 Timer?
The 6200 timer is no longer available. It was an Altronix product we purchased and sold. This product should be available for purchase from Altronix under part number PT724A....
Schlage Commercial » System Components » Power Supplies » PS900 Series » Schlage Electronics
What is the warranty on a Schlage power supply?
The warranty on the PS900 Schlage Electronics Power Supplies is 36 months (3 years) from date of manufacture. The warranty is only valid for a true manufacturing defect in the power supply. Any custom...
Schlage Commercial » System Components » Power Supplies » PS900 Series » Schlage Electronics
Are there MSDS sheets for the batteries in the 900-BB?
Attached are the MSDS (material safety data sheet) of the three different manufacturers of batteries for the 900-BB battery backup. MSDS for 900-BB...
Schlage Commercial » Power Supplies » Standard » PS900 Series » Von Duprin | Schlage Commercial » System Components » Power Supplies » PS900 Series » Schlage Electronics
What power supply replaces the S16HNX?
The S16HNX has been discontinue and is replace by the PS904. Attached is a cross reference of power supplies that been discontinue and what is their replacement.
Power Supply...
Schlage Commercial » Security Management » Schlage Electronics | Schlage Commercial » System Components » Power Supplies » PS900 Series » Schlage Electronics