What replaced the 268 maglock?
There is not a direct replacement for the 268 maglock. The M400 Series Maglocks offer similar features and options. The M450 or M490 are the closest maglock replacements.Choose your replac...
Schlage Commercial » System Components » Electromagnetic Locks » 350+ Series » Schlage Electronics | Schlage Commercial » System Components » Electromagnetic Locks » M400 Series » Schlage Electronics
Can the M490DE be reset during delayed egress?
No the M490DE cannot be reset during the delayed egress time using the standard basic wiring arrangement of separate switch contacts on the RLS (Release) and the RST (Reset), it will not reset during ...
Schlage Commercial » System Components » Electromagnetic Locks » M400 Series » Schlage Electronics
Is a letter of authorization required for the BOCA option on a delayed egress maglock?
The standard BOCA delayed egress time is 15 seconds and a letter from the Authority Having Jurisdiction (AHJ) is not required, only the 30-second delay maglock request requires a letter to provide val...
Schlage Commercial » System Components » Electromagnetic Locks » 101+ Series » Schlage Electronics | Schlage Commercial » System Components » Electromagnetic Locks » 280+ Series » Schlage Electronics | Schlage Commercial » System Components » Electromagnetic Locks » 390DEL Series » Schlage Electronics | Schlage Commercial » System Components » Electromagnetic Locks » M400 Series » Schlage Electronics
How do you test a maglock magnetic pull strength?
The magnetic flux per square inch on the magnetic lock face is too small to test magnetic pull strength with a small piece of metal such as a screwdriver. The maglock must be tested by using the armat...
Schlage Commercial » System Components » Electromagnetic Locks » M400 Series » Schlage Electronics
M400 Series Finish
Satin Aluminum finish is 628...
Schlage Commercial » System Components » Electromagnetic Locks » M400 Series » Schlage Electronics
What finish are the M400 series mag locks
M400 series mag locksare 628 finish: Satin aluminum...
Schlage Commercial » System Components » Electromagnetic Locks | Schlage Commercial » System Components » Electromagnetic Locks » M400 Series | Schlage Commercial » System Components » Electromagnetic Locks » M400 Series » Schlage Electronics
On the M490DEP, should the Alarm Output, put out 30V@1A?
This is contact rating, and not the output; it is a dry contact.
You can run a max of 30V and up to 1 amp through the Alarm Output to drive an LED, horn or other, but the output itself ...
Schlage Commercial » System Components » Electromagnetic Locks » M400 Series | Schlage Commercial » System Components » Electromagnetic Locks » M400 Series » Schlage Electronics