380 Power miser replacement
390+ Can replace the old 380 Power Miser with some additional frame prep holes.
The aramture should be ok.
...
Schlage Commercial » System Components » Electromagnetic Locks » 390+ Series » Schlage Electronics
What type of contact is the MBS switch of the 300 series mag lock?
The MBS is a Form A contact NO. SPST - NO = single pole, single throw - normally open The MBS switch when connected to the 300 series circuit board controls a Form C relay...
Schlage Commercial » System Components » Electromagnetic Locks » 390+ Series » Schlage Electronics
390PIR Not Locking
Verify adequate voltage and current at the mag lock.390PIR Mag Lock Sys Installation and wiring click "here"Dual Voltage: 12 or 24 volts AC or DC(Selected by jumper setting on PC board)Max. Curr...
Schlage Commercial » System Components » Electromagnetic Locks » 390+ Series » Schlage Electronics
320+ 350+ 390+ Unit will not bond
check the following:Properly polarized power inputCorrect voltage 12 or 24 VDC Negative - must be on terminal 1 and the Positive + wire must at terminal 2.Power supply has adequate current to &nb...
Schlage Commercial » System Components » Electromagnetic Locks » 320+ Series » Schlage Electronics | Schlage Commercial » System Components » Electromagnetic Locks » 350+ Series » Schlage Electronics | Schlage Commercial » System Components » Electromagnetic Locks » 390+ Series » Schlage Electronics
Dynamic Holding Force for Maglocks
The dynamic holding force of a magnetic lock refers to the amount sudden impact force necessary to defeat the magnetic bond of the mag head with the armature. Normal or Static holding forc...
Schlage Commercial » System Components » Electromagnetic Locks » 101+ Series » Schlage Electronics | Schlage Commercial » System Components » Electromagnetic Locks » 280+ Series » Schlage Electronics | Schlage Commercial » System Components » Electromagnetic Locks » 320+ Series » Schlage Electronics | Schlage Commercial » System Components » Electromagnetic Locks » 350+ Series » Schlage Electronics | Schlage Commercial » System Components » Electromagnetic Locks » 390+ Series » Schlage Electronics | Schlage Commercial » System Components » Electromagnetic Locks » 390DEL Series » Schlage Electronics | Schlage Commercial » System Components » Electromagnetic Locks » 40 Series » Schlage Electronics | Schlage Commercial » System Components » Electromagnetic Locks » 70 Series » Schlage Electronics
ANSI Numbers with Maglocks
ANSI number Product cross reference can be found in the back of the price book. For example, ANSI number E08561 is specifically for the GF3000, GF3000TJ...
Schlage Commercial » System Components » Electromagnetic Locks » 101+ Series » Schlage Electronics | Schlage Commercial » System Components » Electromagnetic Locks » 280+ Series » Schlage Electronics | Schlage Commercial » System Components » Electromagnetic Locks » 320+ Series » Schlage Electronics | Schlage Commercial » System Components » Electromagnetic Locks » 320M » Schlage Electronics | Schlage Commercial » System Components » Electromagnetic Locks » 350+ Series » Schlage Electronics | Schlage Commercial » System Components » Electromagnetic Locks » 390+ Series » Schlage Electronics | Schlage Commercial » System Components » Electromagnetic Locks » 390DEL Series » Schlage Electronics | Schlage Commercial » System Components » Electromagnetic Locks » 40 Series » Schlage Electronics
Von Duprin DS 4010 equivalent
DS 4010 was a Von Duprin Direct hold, Single Mag Lock from the late 90's.
Today it would be comparable to the Schlage Electronics 390+....
Schlage Commercial » System Components » Electromagnetic Locks » 390+ Series » Schlage Electronics
Do the 390+ and 390DEL have the same footprint?
Yes, but the 390DEL is limited to push side of out swing door....
Schlage Commercial » System Components » Electromagnetic Locks » 390+ Series » Schlage Electronics | Schlage Commercial » System Components » Electromagnetic Locks » 390DEL Series » Schlage Electronics
can the 390 circuit board be bypassed
Yes - The legacy 320 350 and 390 can all have there electronics board bypassed. Doing so will eliminate automatic voltage selection and disable DPS and MBS.for 12 volts wire red/black to po...
Schlage Commercial » System Components » Electromagnetic Locks » 390+ Series » Schlage Electronics
How to put a 390DEL maglock into programming mode
red ibutton or 97531* on keypad if equipped...
Schlage Commercial » System Components » Electromagnetic Locks » 390+ Series » Schlage Electronics | Schlage Commercial » System Components » Electromagnetic Locks » 390DEL Series » Schlage Electronics