Does the 280+ have a built in auto relock switch?
The 280+ does not have a built in auto relock switch you must use the seperate door switch that is included in the box....
Schlage Commercial » System Components » Electromagnetic Locks » 280+ Series » Schlage Electronics
280+ Inrush
280+ maglock has a nominal inrush of 2.0 amp at 12VDC and 1.5 amps inrush at 24 VDC, always make sure the power supply being used can handle the spike in current, If replacing an old 280 wit...
Schlage Commercial » System Components » Electromagnetic Locks » 280+ Series » Schlage Electronics
280+ is loud on locking
Due to the design of the 280+ control module the 280+ when bonding, will be louder then a the typical direct pull mag lock. This can be more pronounced by door and frame material. The boding of the ma...
Schlage Commercial » System Components » Electromagnetic Locks » 280+ Series » Schlage Electronics
Dynamic Holding Force for Maglocks
The dynamic holding force of a magnetic lock refers to the  amount sudden impact force necessary to defeat the magnetic bond of  the mag head with the armature. Normal or Static holding forc...
Schlage Commercial » System Components » Electromagnetic Locks » 101+ Series » Schlage Electronics | Schlage Commercial » System Components » Electromagnetic Locks » 280+ Series » Schlage Electronics | Schlage Commercial » System Components » Electromagnetic Locks » 320+ Series » Schlage Electronics | Schlage Commercial » System Components » Electromagnetic Locks » 350+ Series » Schlage Electronics | Schlage Commercial » System Components » Electromagnetic Locks » 390+ Series » Schlage Electronics | Schlage Commercial » System Components » Electromagnetic Locks » 390DEL Series » Schlage Electronics | Schlage Commercial » System Components » Electromagnetic Locks » 40 Series » Schlage Electronics | Schlage Commercial » System Components » Electromagnetic Locks » 70 Series » Schlage Electronics
ANSI Numbers with Maglocks
 ANSI number Product cross reference can be found in the back of the price book. For example, ANSI number E08561 is specifically for the  GF3000, GF3000TJ...
Schlage Commercial » System Components » Electromagnetic Locks » 101+ Series » Schlage Electronics | Schlage Commercial » System Components » Electromagnetic Locks » 280+ Series » Schlage Electronics | Schlage Commercial » System Components » Electromagnetic Locks » 320+ Series » Schlage Electronics | Schlage Commercial » System Components » Electromagnetic Locks » 320M » Schlage Electronics | Schlage Commercial » System Components » Electromagnetic Locks » 350+ Series » Schlage Electronics | Schlage Commercial » System Components » Electromagnetic Locks » 390+ Series » Schlage Electronics | Schlage Commercial » System Components » Electromagnetic Locks » 390DEL Series » Schlage Electronics | Schlage Commercial » System Components » Electromagnetic Locks » 40 Series » Schlage Electronics
What mag lock replaced the former Von Duprin 700?
There is not a direct replacement for the old Von Duprin 700 Shear Lock series mag lock.The Von Duprin 700 had been replaced by the old Locknetics 280-700, which has also since been discontinued, and ...
Schlage Commercial » System Components » Electromagnetic Locks » 280+ Series | Schlage Commercial » System Components » Electromagnetic Locks » 280+ Series » Schlage Electronics | Schlage Commercial » System Components » Electromagnetic Locks » GF3000 Series | Schlage Commercial » System Components » Electromagnetic Locks » GF3000 Series » Schlage Electronics | Schlage Commercial » Von Duprin
What is the 280XTRD Mag Lock?
The 280xTRD is an obsolete complete shear lock. GF3000TRD  is the nearest functional replacement. The GF3000TRD is a little larger than the 280xTRD....
Schlage Commercial » System Components » Electromagnetic Locks » 280+ Series » Schlage Electronics
What is the part number for the delayed egress sign for the M490DE/DEP?
The part number for the M490DE sign is P774358...
Schlage Commercial » System Components » Electromagnetic Locks » 101+ Series » Schlage Electronics | Schlage Commercial » System Components » Electromagnetic Locks » 280+ Series » Schlage Electronics | Schlage Commercial » System Components » Electromagnetic Locks » 390DEL Series » Schlage Electronics | Schlage Commercial » System Components » Electromagnetic Locks » M400 Series » Schlage Electronics
Do the magnetic locks take AC voltage?
Do magnetic locks take AC voltage?No, maglocks only take 12 or 24 volts DC from a filtered and regulated power supply, generally at less than 1 amp @ 12vdc, and .5 amp @ 24vdc.(See the installation or...
Schlage Commercial » System Components » Electromagnetic Locks | Schlage Commercial » System Components » Electromagnetic Locks » 101+ Series | Schlage Commercial » System Components » Electromagnetic Locks » 101+ Series » Schlage Electronics | Schlage Commercial » System Components » Electromagnetic Locks » 280+ Series | Schlage Commercial » System Components » Electromagnetic Locks » 280+ Series » Schlage Electronics | Schlage Commercial » System Components » Electromagnetic Locks » 320+ Series | Schlage Commercial » System Components » Electromagnetic Locks » 320+ Series » Schlage Electronics | Schlage Commercial » System Components » Electromagnetic Locks » 320M | Schlage Commercial » System Components » Electromagnetic Locks » 320M » Schlage Electronics | Schlage Commercial » System Components » Electromagnetic Locks » 350+ Series | Schlage Commercial » System Components » Electromagnetic Locks » 350+ Series » Schlage Electronics | Schlage Commercial » System Components » Electromagnetic Locks » 390+ Series | Schlage Commercial » System Components » Electromagnetic Locks » 390+ Series » Schlage Electronics | Schlage Commercial » System Components » Electromagnetic Locks » 390DEL Series | Schlage Commercial » System Components » Electromagnetic Locks » 390DEL Series » Schlage Electronics | Schlage Commercial » System Components » Electromagnetic Locks » 40 Series | Schlage Commercial » System Components » Electromagnetic Locks » 40 Series » Schlage Electronics | Schlage Commercial » System Components » Electromagnetic Locks » 70 Series | Schlage Commercial » System Components » Electromagnetic Locks » 70 Series » Schlage Electronics | Schlage Commercial » System Components » Electromagnetic Locks » GF3000 Series | Schlage Commercial » System Components » Electromagnetic Locks » GF3000 Series » Schlage Electronics | Schlage Commercial » System Components » Electromagnetic Locks » M390RFK | Schlage Commercial » System Components » Electromagnetic Locks » M390RFK » Schlage Electronics | Schlage Commercial » System Components » Electromagnetic Locks » M400 Series | Schlage Commercial » System Components » Electromagnetic Locks » M400 Series » Schlage Electronics
Is a letter of authorization required for the BOCA option on a delayed egress maglock?
The standard BOCA delayed egress time is 15 seconds and a letter from the Authority Having Jurisdiction (AHJ) is not required, only the 30-second delay maglock request requires a letter to provide val...
Schlage Commercial » System Components » Electromagnetic Locks » 101+ Series » Schlage Electronics | Schlage Commercial » System Components » Electromagnetic Locks » 280+ Series » Schlage Electronics | Schlage Commercial » System Components » Electromagnetic Locks » 390DEL Series » Schlage Electronics | Schlage Commercial » System Components » Electromagnetic Locks » M400 Series » Schlage Electronics