101+ delayed egress triggered on power up
When lock goes into delayed egress upon power up check the following make sure all armature washers are installed properly.  alignment between mag and armature correct screws used for mounti...
Schlage Commercial » System Components » Electromagnetic Locks » 101+ Series » Schlage Electronics
101+ or 390DEL After memory clear Relock delay may reset to 1 second.
If memory is cleared on delayed egress maglocks they may revert to a 1 second relock time. The relock delay will need to be reset to a value between 6 - 8 seconds. The max delay is 30 seconds....
Schlage Commercial » System Components » Electromagnetic Locks » 101+ Series » Schlage Electronics | Schlage Commercial » System Components » Electromagnetic Locks » 390DEL Series » Schlage Electronics
Does the 101+ or 390DEL require a spike supressor?
The 101+  and 390DEL mag locks have built in spike suppression. There should not be any type of diode, resistor, or supression put at terminals 1 and 2. can cause residual magnetism ...
Schlage Commercial » System Components » Electromagnetic Locks » 101+ Series » Schlage Electronics | Schlage Commercial » System Components » Electromagnetic Locks » 390DEL Series » Schlage Electronics
New Delay Egress Maglock Replacing the 390DEL and 101+
The 390DEL and 101+ maglocks have been discontinued. They are being replaced within the product line to the M490DE, a plunger-switch activated delayed egress maglock much like the 390DEL....
Schlage Commercial » System Components » Electromagnetic Locks » 101+ Series » Schlage Electronics | Schlage Commercial » System Components » Electromagnetic Locks » 390DEL Series » Schlage Electronics
101+ or 390DEL not locking
Check power at terminals 1 and 2 (12 or 24V AC/DC ).When lock has power but will not lock check dip switch SW4-7 (Automatic Relock) and ensure it is on.[101+ only] Ensure SW1 the red slide switch is i...
Schlage Commercial » System Components » Electromagnetic Locks » 101+ Series » Schlage Electronics | Schlage Commercial » System Components » Electromagnetic Locks » 390DEL Series » Schlage Electronics
What is the Voltage requirement for the 101-2+?
The 101-2+ only operates with an input voltage of 12V AC/DC .8A total for both magnets.The master normally can run at 12 or 24 but must run at 12 vdc when paired with the slave (12vdc only)...
Schlage Commercial » System Components » Electromagnetic Locks » 101+ Series » Schlage Electronics
How to configure a master slave unit together for 101-2+ to trigger from aux OR rocker inputs
When using a 101-2+  mag lock you need to make sure that dip switch #3 on switch SW4 is in the ON position, and that the rocker switch from the slave is connected to terminals #5&6 on the mas...
Schlage Commercial » System Components » Electromagnetic Locks » 101+ Series » Schlage Electronics
390 DEL System 7 Programming swich positioning.
When using system seven programming, ensure  proper  switch positioning. Locate the SW4  dip switch bank, Set  the Number 1 position to off when programming ibuttons. If SW4, posit...
Schlage Commercial » System Components » Electromagnetic Locks » 101+ Series » Schlage Electronics | Schlage Commercial » System Components » Electromagnetic Locks » 390DEL Series » Schlage Electronics
390 DEL-2 vs 101-2+ Master and Slave Replacement Units
The nearest functional equivalent to replace the legacy Master slave delayed egress mag locks is the M490DE-2  or M490DEP-2....
Schlage Commercial » System Components » Electromagnetic Locks » 101+ Series » Schlage Electronics | Schlage Commercial » System Components » Electromagnetic Locks » 390DEL Series » Schlage Electronics | Schlage Commercial » System Components » Electromagnetic Locks » M400 Series
Dynamic Holding Force for Maglocks
The dynamic holding force of a magnetic lock refers to the  amount sudden impact force necessary to defeat the magnetic bond of  the mag head with the armature. Normal or Static holding forc...
Schlage Commercial » System Components » Electromagnetic Locks » 101+ Series » Schlage Electronics | Schlage Commercial » System Components » Electromagnetic Locks » 280+ Series » Schlage Electronics | Schlage Commercial » System Components » Electromagnetic Locks » 320+ Series » Schlage Electronics | Schlage Commercial » System Components » Electromagnetic Locks » 350+ Series » Schlage Electronics | Schlage Commercial » System Components » Electromagnetic Locks » 390+ Series » Schlage Electronics | Schlage Commercial » System Components » Electromagnetic Locks » 390DEL Series » Schlage Electronics | Schlage Commercial » System Components » Electromagnetic Locks » 40 Series » Schlage Electronics | Schlage Commercial » System Components » Electromagnetic Locks » 70 Series » Schlage Electronics