Are the 6000 series strikes field selectable for 12 or 24 VDC?
All 6000 series electric strike would require the solenoid be replaced to convert from one voltage to the other....
Schlage Commercial » System Components » Electric Strikes » 6000 Series » Von Duprin
Are the 6000 electric strikes UL listed for fire rated openings?
Only fail secure 6000 series electric strikes are UL listed for fire rated openings....
Schlage Commercial » System Components » Electric Strikes » 6000 Series » Von Duprin
What is the part number for the 6000 series solenoid?
The Von Duprin 6000 series electric strike can be converted by ordering the appropriate kits below.6000 Series solenoid Kit 12VDC - 050237-00Yellow wires6000 Series solenoid Kit 16VDC - 050239-00Blue ...
Schlage Commercial » System Components » Electric Strikes » 6000 Series » Von Duprin
What electric strike should be used with cylindrical locks on double door pair with no mullion?
Von Duprin 6223 is the most common electric strike that is used with cylindrical locks on inactive leaf on double door with no mullion....
Schlage Commercial » System Components » Electric Strikes » 6000 Series » Von Duprin
What is the backset of the 99 device when used with a 6111 electric strike?
The back set for 98/99 device is 2 7/16" from top of the stop on single door and 3 7/16" on double door with 4854 mullion. See attached templates, dimension B.   6111 Electric Strike Templat...
Schlage Commercial » Exit Devices » Touch Bar » 98/99 Series » Von Duprin | Schlage Commercial » System Components » Electric Strikes » 6000 Series » Von Duprin
Will the 6210 work with the Best 45H? If not is there another electric strike that is compatible.
***The 6210 electric strike was designed to replace mechanical strikes in existing openings when access control is desired.*** Note: The Best 40H series lock is not listed on the 6210 electric str...
Schlage Commercial » System Components » Electric Strikes » 6000 Series » Von Duprin
Can I use a 6210 in a wood frame?
Standard 6210 can't be used in a wood frame. ...
Schlage Commercial » System Components » Electric Strikes » 6000 Series » Von Duprin
Does Von Duprin make a 16 volt DC solenoid for 6000 series electric strike?
The 16VDC electric strike solenoid is part number 050239-00....
Schlage Commercial » System Components » Electric Strikes » 6000 Series » Von Duprin
Can the 24-R be used with the Von Duprin 6111 electric strike?
The 24-R can be used with the Von Duprin 6111 electric strike.   The 6111 has the same projection as the 299 strike and the Von Duprin 4854 electrified mullion has the same dimensions a...
Schlage Commercial » Exit Devices » Touch Bar » 24 Series | Schlage Commercial » Exit Devices » Touch Bar » 24 Series » Falcon | Schlage Commercial » System Components » Electric Strikes » 6000 Series | Schlage Commercial » System Components » Electric Strikes » 6000 Series » Von Duprin | Schlage Commercial » Von Duprin
Does Von Duprin offer an electric strike in the 6000 Series that works with a deadbolt only?
Von Duprin offers no such strike.  The reason being that the deadbolt would bounce off the strike’s keeper and prevent the door from securing....
Schlage Commercial » System Components » Electric Strikes » 6000 Series | Schlage Commercial » System Components » Electric Strikes » 6000 Series » Von Duprin