Category: Von Duprin

(Results from 61 to 70)
What is the part number for the 6210 spring and lip replacement package?
You can replace the 6210 spring and lip, part number 050940-00....
Schlage Commercial » System Components » Electric Strikes » 6000 Series » Von Duprin
Which electric strike would I use with an HL6?
You could use the HL6 Hospital Latch with any electric strike that would work with a cylinderical latch such as the 5100, 6211, etc....
Schlage Commercial » System Components » Electric Strikes » 5100 Series » Von Duprin | Schlage Commercial » System Components » Electric Strikes » 6000 Series » Von Duprin
Will a 6211 strike work on a double door?
Not advisable, the 6211 is designed to fit in a square edged frame.  You need an appropriate strike for a beveled edge door....
Schlage Commercial » System Components » Electric Strikes » 6000 Series » Von Duprin
Will a 6211 work with a Falcon MA581?
The 6211 dan be used with the Falcon MA581, use the "B" dimension of 1/16" on 6211 template....
Schlage Commercial » System Components » Electric Strikes » 6000 Series » Von Duprin
Can the 6000 series strikes be used outside?
None of our 6000 series electric strikes are rated for exterior applications where the strike is fully exposed to the elements.  If they were to be used in that situation and the elements caused ...
Schlage Commercial » System Components » Electric Strikes » 6000 Series » Von Duprin
What Von Duprin electric strike will work with a Yale 7150?
Von Duprin does not offer an electric strike to operate with Yale 7150 exit device....
Schlage Commercial » System Components » Electric Strikes » 6000 Series » Von Duprin
How many wires does the 6210 use?
All 6000 series electric strikes have two wires for solenoid and six wires for DS option....
Schlage Commercial » System Components » Electric Strikes » 6000 Series » Von Duprin
Which Von Duprin electric strike can be used with 9947 LBR exit device?
Von Duprin 6213 electric strike can be used with 98/9947-LBR exit device with pullman latch on non fire rated openings....
Schlage Commercial » Exit Devices » Touch Bar » 98/99 Series » Von Duprin | Schlage Commercial » System Components » Electric Strikes » 6000 Series » Von Duprin
Is the device centerline of the 9975, the same as the centerline of the 6223 strike?
The centerline of 6223 is the same as the centerline of the mortise latch bolt.  So the centerline of the mortise latch bolt or center line of the 6223 is 15/32" above the centerline of the de...
Schlage Commercial » Exit Devices » Touch Bar » 98/99 Series » Von Duprin | Schlage Commercial » System Components » Electric Strikes » 6000 Series » Von Duprin
Can an electric strike be added to a KR4954?
The 6111 electric strike be added to a KR4954.The 6111 x 4854 template is needed for the cut out.KR54-F kit 050169-xxMale connector wire assembly 105987-00Female receptacle wire assembly 105988-00...
Schlage Commercial » Exit Devices » Mechanical Accessories » Mullion » Von Duprin | Schlage Commercial » System Components » Electric Strikes » 6000 Series » Von Duprin