Can 24 volts be run to a 12 volt 6000 series electric strike solenoid?
You can't run 24VDC into the 12VDC electric strike, over voltage such as this will cause the solenoid to heat up and damage the solenoid. You must change to a 24V solenoid, part number 050240-00....
Schlage Commercial » System Components » Electric Strikes » 6000 Series » Von Duprin | Schlage Commercial » System Components » Electrified System Component Accessories » Rectifier » Von Duprin
Will the Von Duprin 6210 electric strike operate with the MA series locks?
The Von Duprin 6210 electric strike was designed for retrofit applications and will not work with the Falcon MA series lock when strike and lock body are mounted at standard locations (centerline of...
Schlage Commercial » Mechanical Locks » Mortised » MA-Series » Falcon | Schlage Commercial » System Components » Electric Strikes » 6000 Series » Von Duprin
Is there a RX switch for the 6000 electric strikes?
The only switches available for the 6000 electric strikes are the DS Dual Switches. In the Dual Switch configuration one switch monitors the strike pocket, presumably is the latch bolt inse...
Schlage Commercial » System Components » Electric Strikes » 6000 Series » Von Duprin
What is the device backset when using a 1790 with a 6111 strike?
The Von Duprin 6111 electric strike would work with DOM 1790 device on medium style doors
Centerline of the 1790 device mounting screws are located 1 11/16" from face of stop. See draw...
Schlage Commercial » Exit Devices » Touch Bar » 1790 Series » Falcon | Schlage Commercial » System Components » Electric Strikes » 6000 Series » Von Duprin