Category: Power Supplies

(Results from 31 to 40)
What kind of wire do I need to use when my device is ___ feet away from my power supply?
* Use 12AWG wire for up to 800’ between your power supply and your device. * Use 14AWG wire for up to 500’ between your power supply and your device. * Use 16AWG wire for up to 300 between your ...
Schlage Commercial » Power Supplies
How many option boards can be installed in the PS902?
Only 1 option board can be installed in the PS902....
Schlage Commercial » Power Supplies | Schlage Commercial » Power Supplies » Standard » PS900 Series
Can a QEL device be wired so that it stays open during a fire condition?
This must not be done on a fire rated opening. From a wiring standpoint, wiring the fire alarm signal as an input to a power supply  logic board (using it as an access control input) would ...
Schlage Commercial » Power Supplies
Why are the 900-4RL option board red and green lights flashing in an alternating manner?
If the SW2 dipswitches are improperly both set to ON, the red and green lights will strobe to indicate an error.   See the 900-4RL instructions to properly set SW2. ...
Schlage Commercial » Power Supplies | Schlage Commercial » Power Supplies » Standard » PS900 Series | Schlage Commercial » Power Supplies » Standard » PS900 Series » Von Duprin | Schlage Commercial » System Components » Power Supplies » PS900 Series
Are the standoffs replaceable on the PS900 series power supplies?
The standoffs or mounting posts for mounting circuit boards are a very tight press fit.  They should not loosen.  If the standoffs have loosened or are missing, they can not be put back in p...
Schlage Commercial » Power Supplies | Schlage Commercial » Power Supplies » Standard | Schlage Commercial » Power Supplies » Standard » PS900 Series | Schlage Commercial » Power Supplies » Standard » PS900 Series » Von Duprin | Schlage Commercial » System Components » Power Supplies | Schlage Commercial » System Components » Power Supplies » PS900 Series | Schlage Commercial » System Components » Power Supplies » PS900 Series » Schlage Electronics
Can a PS861 power supply operate a QELA device?
The PS861 power supply can provide 1 amp at 24 VDC which would be sufficient to power 1 QELA device....
Schlage Commercial » Power Supplies
What is the 900-8P option board function for the PS900 power supply series?
8 independent PTC protected outputs. They are devices that automatically break the circuit when it gets too much amperage and automatically resets the thermal fuse once the overdraw has cleared....
Schlage Commercial » Power Supplies | Schlage Commercial » Power Supplies » Standard » PS900 Series | Schlage Commercial » System Components » Power Supplies » PS900 Series | Schlage Commercial » System Components » Power Supplies » PS900 Series » Schlage Electronics
What is the fuse information for a PS873 power supply?
The PS873 (discontinued in January 2011) uses a slow blow 4A, 250V, 1/4" x 1 1/4" fuse.  A slow blow fuse is required because the EL device 16 amp surge would ruin an ordinary fuse.  To chec...
Schlage Commercial » Power Supplies | Schlage Commercial » Von Duprin
Warranty information on Allegion Commercial products.
See here for our Warranty Information. ...
Schlage Commercial » Automatic Operators | Schlage Commercial » Biometrics | Schlage Commercial » Credentials | Schlage Commercial » Door Controls | Schlage Commercial » Electronic Locks | Schlage Commercial » Exit Devices | Schlage Commercial » Key Systems | Schlage Commercial » Mechanical Accessories | Schlage Commercial » Mechanical Locks | Schlage Commercial » Power Supplies | Schlage Commercial » Readers | Schlage Commercial » Security Management | Schlage Commercial » Software | Schlage Commercial » System Components | Schlage Commercial » Falcon | Schlage Commercial » Glynn-Johnson | Schlage Commercial » Ives | Schlage Commercial » LCN | Schlage Commercial » Schlage | Schlage Commercial » Schlage Electronics | Schlage Commercial » Steelcraft | Schlage Commercial » Von Duprin | Schlage Commercial | Schlage Commercial » Dexter | Schlage Commercial » Zero | Schlage Commercial » Sealing Systems | Schlage Commercial » Readers » IP Based
How the 900-FA board functions with the PS914-4RL?
The 900-FA board is used to disrupt output power of the board upon which it is mounted. The 900-FA board uses a Normally Closed Dry Contact, normally from the Fire Alarm System.When that contact ...
Schlage Commercial » Power Supplies | Schlage Commercial » Von Duprin | Schlage Commercial » Glossary » Exits