Category: Schlage Electronics

(Results from 1 to 10)
Ethernet LED indications for EN-200
Normal Operating: Red off, green on - Idle, waiting for connection Red off, green blinking - Network connection to serial port established Red blinking, green (Status LED) blinkin...
Schlage Commercial » Biometrics » HandKey » HandKey II » Schlage Electronics | Schlage Commercial » Biometrics » HandKey » ID3D » Schlage Electronics | Schlage Commercial » Biometrics » HandPunch » HP 1000 » Schlage Electronics | Schlage Commercial » Biometrics » HandPunch » HP 3000 » Schlage Electronics
DC-104 HandKey II wiring
For RS-422 wiring: DC-104 HK-2 set dipswitch to: wire to: pin: RS-422 T...
Schlage Commercial » Biometrics » FingerKey » FingerKey DX Series » Schlage Electronics | Schlage Commercial » Biometrics » HandKey » HandKey II » Schlage Electronics | Schlage Commercial » Biometrics » HandKey » ID3D » Schlage Electronics | Schlage Commercial » Biometrics » HandPunch » HP 3000 » Schlage Electronics
A customer has an ID3D with a bad ethernet and wants to order a field-upgradeable ethernet card. What part number should they use?
The EN-100 that is specified for the E-series (ID3D) products is a factory-installed-only option....
Schlage Commercial » Biometrics » HandKey » HandKey II » Schlage Electronics | Schlage Commercial » Biometrics » HandKey » ID3D » Schlage Electronics
Where on the ID3D HandKey, do you set the IP address if an Ethernet card is installed?
The IP address and other network configurations can be found under Password Setup Menu 2 and then "Set Serial" option.  There, settings can be found for the IP address, Gateway, Host Bits, and Ba...
Schlage Commercial » Biometrics » HandKey » ID3D » Schlage Electronics
Does switching the time format from 24 hour to 12 hour on an E or F series HandReader, store the time in the same format on the transaction?
No, the time is switched back....
Schlage Commercial » Biometrics » HandKey » HandKey CR » Schlage Electronics | Schlage Commercial » Biometrics » HandKey » HandKey II » Schlage Electronics | Schlage Commercial » Biometrics » HandKey » ID3D » Schlage Electronics | Schlage Commercial » Biometrics » HandPunch » HP 1000 » Schlage Electronics | Schlage Commercial » Biometrics » HandPunch » HP 2000 » Schlage Electronics | Schlage Commercial » Biometrics » HandPunch » HP 3000 » Schlage Electronics | Schlage Commercial » Biometrics » HandPunch » HP 4000 » Schlage Electronics
What is the part number for the E-series Blizzard outdoor enclosure?
HP-RW for the E-series HandPunch, ID3D-RW or LH-100RW for the E-series HandKey....
Schlage Commercial » Biometrics » HandKey » ID3D » Schlage Electronics
What steps do I take if I see a "Seeking Ethernet Adapter" message on a biometric Hand Reader followed by "Not Found"?
The first step in troubleshooting a possible Ethernet connection problem and a biometric Hand Reader is to boot the reader.  When you boot the reader, does it displays "Seeking Ethernet Adapter" ...
Schlage Commercial » Biometrics » HandKey » HandKey II » Schlage Electronics | Schlage Commercial » Biometrics » HandKey » ID3D » Schlage Electronics | Schlage Commercial » Biometrics » HandPunch » HP 1000 » Schlage Electronics | Schlage Commercial » Biometrics » HandPunch » HP 3000 » Schlage Electronics
What happens when you assign all of the password menus on the F and E series readers the same password?
The 5 Command Groups will be combined by assigning them the same password starting with those in password menu 5 and then ending with those in password menu 1.  In this case, the command choices ...
Schlage Commercial » Biometrics » HandKey » HandKey CR » Schlage Electronics | Schlage Commercial » Biometrics » HandKey » HandKey II » Schlage Electronics | Schlage Commercial » Biometrics » HandKey » ID3D » Schlage Electronics | Schlage Commercial » Biometrics » HandPunch » HP 1000 » Schlage Electronics | Schlage Commercial » Biometrics » HandPunch » HP 2000 » Schlage Electronics | Schlage Commercial » Biometrics » HandPunch » HP 3000 » Schlage Electronics | Schlage Commercial » Biometrics » HandPunch » HP 4000 » Schlage Electronics
What information is stored in a user template record in a biometric F-Series hand reader?
Template, ID, Time Zone, and Authority Level are the four fields that make up a basic user template in a biometric F-Series or E-Series hand reader....
Schlage Commercial » Biometrics » HandKey » HandKey II » Schlage Electronics | Schlage Commercial » Biometrics » HandKey » ID3D » Schlage Electronics | Schlage Commercial » Biometrics » HandPunch » HP 1000 » Schlage Electronics | Schlage Commercial » Biometrics » HandPunch » HP 2000 » Schlage Electronics | Schlage Commercial » Biometrics » HandPunch » HP 3000 » Schlage Electronics | Schlage Commercial » Biometrics » HandPunch » HP 4000 » Schlage Electronics
Is the E-Series HandKey handed?
Yes, the E-Series HandKey is handed: Interior applications: ID3D-R is a right handed E-Series HandKey LH-100 is a left handed E-Series HandKey Exterior applications: ID3D-R...
Schlage Commercial » Biometrics » HandKey » ID3D » Schlage Electronics