Can the Schlage L mortise lock have escutcheon trim one side and rose trim on the other side?
The Schlage L mortise lock can only be ordered with either escutcheon trim on both sides or rose trim on both sides.  Split trim (rose x escutcheon) is not supported.     &nb...
Schlage Commercial » Mechanical Locks » Mortised » L9000 Series
What size torx screw is used on the L9000 HSLR ligature resistant trim?
The armor front and trim plates use a T-15 security torx....
Schlage Commercial » Mechanical Locks » Mortised » L9000 Series
Can the L9000 HSLR ligature trim be installed one side?
The L9000 HSLR can not be installed one side only.  A complete inside and outside lock must be installed....
Schlage Commercial » Mechanical Locks » Mortised » L9000 Series
When did the L9000 HSLR ligature trim launch?
The L9000 HSLR ligature trim launched on May 27th, 2019....
Schlage Commercial » Mechanical Locks » Mortised » L9000 Series
Is ligature resistant trim available for a door thickness other than 1 3/4"?
Ligature resistant trim can only be installed onto a 1 3/4" thick door.Includes the SL1/SK1 and HSLR trims....
Schlage Commercial » Mechanical Locks » Mortised » L9000 Series
What are the (4) # 10-32 x 3/8" TRPHMS screws used for that are shipped with HL6-L9000?
These screws can be used to fasten the top two screws of the paddle assembly directly to the door (metal door only).  It would be used in place of the stud assembly (part H- see here). ...
Schlage Commercial » Mechanical Locks » Mortised » L9000 Series | Schlage Commercial » Mechanical Locks » Push/Pull Latches | Schlage Commercial
Why is the L9040 and L9440 not available with HSLR trim?
The access hole for the emergency key would be a possible ligature point....
Schlage Commercial » Mechanical Locks » Mortised | Schlage Commercial » Mechanical Locks » Mortised » L9000 Series
What is the P, R, and B stamped on the back of the HSLR blocking rings?
The HSLR blocking rings are marked on the back surface.  P= KILR=FSICB=SFIC...
Schlage Commercial » Mechanical Locks » Mortised | Schlage Commercial » Mechanical Locks » Mortised » L9000 Series
Does the HSLR trim meet ADA guidelines?
The HSLR trim meets the guidelines set forth by ADA.  See attached letter....
Schlage Commercial » Mechanical Locks » Cylindrical » ND Series | Schlage Commercial » Mechanical Locks » Mortised » L9000 Series
Why would the outside lever activate the RX switch on the electrified L9000 mortise locks?
A couple items may cause this:Springcage may be installed backwards - Springcage must be installed with arrows going in the downward rotation of lever. The L9090 lever hubs will rotate together w...