Is the tailpiece the same for the ND series and the NDe series?
The ND and the NDe tailpieces are the same since early 2017. The part numbers for the tailpiece options are shown below:DESCRIPTIONSUFFIXTAILPIECE/ KIT P/NDRIVER, SCHLAGE KIK/STANDARD PDN523-022D...
Schlage Commercial » Electronic Locks | Schlage Commercial » Mechanical Locks » Cylindrical » ND Series | Schlage Commercial » Mechanical Locks » Cylindrical » ND Series » Schlage | Schlage Commercial » Electronic Locks » NDE Series
Can a diode be used with the ND electrified lock?
As long as the voltage delivered to the wires of the electrified ND lock is between 10.2VDC and 26.4VDC, a diode, or string of diodes, in series with the positive output of the power supply should not...
Schlage Commercial » Mechanical Locks » Cylindrical » ND Series
What is the maximum voltage for the ND12, ND80 or ND96 electrified lock?
The maximum DC voltage for the ND12, ND80, ND96 electrified lock is 12vdc - 24vdc +10% or 10.8 TO 26.4vdc....
Schlage Commercial » Mechanical Locks » Cylindrical | Schlage Commercial » Mechanical Locks » Cylindrical » ND Series
What is included in the CON-KIT?
Please see here a list of all parts included in CON-KIT. ...
Schlage Commercial » Mechanical Locks » Cylindrical » T Series | Schlage Commercial » Mechanical Locks » Cylindrical » ND Series | Schlage Commercial » Mechanical Locks » Mortised » MA-Series | Schlage Commercial » Mechanical Locks » Mortised » L9000 Series
Can the electrified ND lock be used in an outside application?
Not recommended for outdoor installations....
Schlage Commercial » Mechanical Locks » Cylindrical » ND Series
How to remove or install the ND40 or ND44 outside lever.
Open the door to access both sides of the lock.Push inside buttonOn the outside leverND40 – Insert flat tip screwdriver into privacy openingND44 - Turn the emergency turn-buttonRotate cloc...
Schlage Commercial » Mechanical Locks » Cylindrical » ND Series
How does the ND73 function?
Lock can be locked or unlocked by the key on the outsidePush button on inside lever locks outside leverTurning the inside lever or closing the door will release the push buttonIf the outside lever is ...
Schlage Commercial » Mechanical Locks | Schlage Commercial » Mechanical Locks » Cylindrical | Schlage Commercial » Mechanical Locks » Cylindrical » ND Series | Schlage Commercial » Mechanical Locks » Cylindrical » ND Series » Schlage | Schlage Commercial
Can you order an ND chassis only for thick doors?
The ND chassis cannot be ordered with extended door thickness over 2 1/8".   ...
Schlage Commercial » Mechanical Locks » Cylindrical » ND Series
What is the black piece that sits behind the tail piece on ND FSIC lock when shipped less core?
The IC spindle insert was shipped on ND locks ordered less FSIC on locks shipped prior to January 30th 2017 to hold the FSIC driver in place reducing the chances of misplacing the driver.  See&nb...
Schlage Commercial » Mechanical Locks » Cylindrical » ND Series
Does the ND JD-SAR prep accept Sargent "Degree" core?
The ND-series JD-SAR prep will accept Sargent Degree core....