Is EL and SD available togther on the 33A / 35A devices?
Cylinder dogging (SD) which is contained in the head of the device and 33A/35A device head is not wide enough for a SD cylinder dogging....
Schlage Commercial » Exit Devices » Touch Bar » 33A/35A Series » Von Duprin
What is needed to keep the EL device retracted all day?
To keep the Von Duprin electric latch retraction EL or QELA exit device dogged (retracted) all day, have your access control, Key pad, key switch, fire alarm contact or any other signals to ...
Schlage Commercial » Exit Devices » Recessed » 94/95 Series INPACT » Von Duprin | Schlage Commercial » Exit Devices » Touch Bar » 33A/35A Series » Von Duprin | Schlage Commercial » Exit Devices » Touch Bar » 98/99 Series » Von Duprin | Schlage Commercial » Power Supplies » Standard » PS900 Series » Von Duprin
Can you get a 33/35A Rim device fire rated?
Yes.  A fire rating was approved in 2016.Please see the 33A/35A catalog here for more information:http://us.allegion.com/content/dam/allegion-us-2/web-documents-2/Catalog/Von_Duprin_33A.35A_Serie...
Schlage Commercial » Exit Devices » Touch Bar » 33A/35A Series » Von Duprin
How do I wire an EL device to normally hold open the latch and release it during a fire alarm?
Use a normally closed fire alarm as the input to the power supply option board (PS873-2 or PS914-2RS), this will hold the latch retracted.  During a fire alarm, the contact will open, dropping po...
Schlage Commercial » Exit Devices » Touch Bar » 24 Series » Falcon | Schlage Commercial » Exit Devices » Touch Bar » 25 Series » Falcon | Schlage Commercial » Exit Devices » Touch Bar » 33A/35A Series » Von Duprin | Schlage Commercial » Exit Devices » Touch Bar » 98/99 Series » Von Duprin | Schlage Commercial » Power Supplies » Standard » PS900 Series » Von Duprin
Can you add the LX option to a Von Duprin device that already has the RX option?
The Von Duprin RXLX combination switch must be ordered together as one assembly. Existing RX or LX switch must be removed to install the combination RX LX switch. Make sure correct RX LX combination s...
Schlage Commercial » Exit Devices » Touch Bar » 22 Series » Von Duprin | Schlage Commercial » Exit Devices » Touch Bar » 33A/35A Series » Von Duprin | Schlage Commercial » Exit Devices » Touch Bar » 98/99 Series » Von Duprin
What the differance between 313 and 313AN on Von Duprin Exit devices?
313 is powder coat and 313AN is anodized finish. We no longer provide anodize finishes with VD exit devices....
Schlage Commercial » Exit Devices » Touch Bar » 33A/35A Series » Von Duprin | Schlage Commercial » Exit Devices » Touch Bar » 98/99 Series » Von Duprin
What could cause the Von Duprin exit alarm ALK to turn off after one or two minutes?
If the spring on the Von Duprin exit alarm ALK board is not located correctly as shown on the instructions, then the vibration from the horn allows the cylinder to turn and shut the exit alarm ALK of...
Schlage Commercial » Exit Devices » Touch Bar » 22 Series » Von Duprin | Schlage Commercial » Exit Devices » Touch Bar » 33A/35A Series » Von Duprin | Schlage Commercial » Exit Devices » Touch Bar » 98/99 Series » Von Duprin
Does Von Duprin still carry the 334 cylinder control?
No longer available, the 334 cylinder control was for the old style 33/35 series exit devices which was discontinued in August 2003....
Schlage Commercial » Exit Devices » Touch Bar » 33A/35A Series » Von Duprin | Schlage Commercial » Von Duprin
Can the 264 strike be used with "insert exit device here"?
The 264 can be used with any device that the 299 can be used with....
Schlage Commercial » Exit Devices » Cross Bar » 55 Series » Von Duprin | Schlage Commercial » Exit Devices » Cross Bar » 88 Series » Von Duprin | Schlage Commercial » Exit Devices » Touch Bar » 22 Series » Von Duprin | Schlage Commercial » Exit Devices » Touch Bar » 33A/35A Series » Von Duprin | Schlage Commercial » Exit Devices » Touch Bar » 98/99 Series » Von Duprin
Why would you use a 1 piece surface top rod for an 8ft door instead of adding an extension rod to the standard rod?
You would use one piece top rod instead of adding an extension rod to the standard surface vertical rod exit device so you do not see the seam of the 2 rods together....
Schlage Commercial » Exit Devices » Cross Bar » 88 Series » Von Duprin | Schlage Commercial » Exit Devices » Touch Bar » 33A/35A Series » Von Duprin | Schlage Commercial » Exit Devices » Touch Bar » 98/99 Series » Von Duprin