Do I have to use the 388 to get NL-OP on a 33A/35A series device?
The 388 Cylinder Control is required for the NL-OP function on a 33A/35A series exit devices.The 110NL is used on 22 and 98/99 series exit devices not 33/35A series devices.The 33A/35A devic...
Schlage Commercial » Exit Devices » Touch Bar » 33A/35A Series » Von Duprin | Schlage Commercial » Von Duprin
Can Von Duprin QEL/EL and CX be in the same device?
You can not use these options together on the same device per the following reasons:
QEL/EL device retracts the latch bolt of the exit device allowing entry.
CX (Chexit) device loc...
Schlage Commercial » Exit Devices » Touch Bar » 33A/35A Series » Von Duprin | Schlage Commercial » Exit Devices » Touch Bar » 98/99 Series » Von Duprin
Can you power an EL device from a senior swing?
Their is not enough power on a Senior Swing to power an EL device, need PS914-2RS/4RL power supply....
Schlage Commercial » Automatic Operators » Electrohydraulic » 4630 Series » LCN | Schlage Commercial » Exit Devices » Touch Bar » 33A/35A Series » Von Duprin | Schlage Commercial » Exit Devices » Touch Bar » 98/99 Series » Von Duprin
Which LX switch do I use on a QEL33A/35A/98/99 devices?
The QEL33A/35A/98/99 devices will use the standard LX switch, 050254 for 3' devices and 050255 for 4' devices field installed and 050252 for 3' devices and 050253 for 4' devices factory...
Schlage Commercial » Exit Devices » Touch Bar » 33A/35A Series » Von Duprin | Schlage Commercial » Exit Devices » Touch Bar » 98/99 Series » Von Duprin
Can RG-27 be used on a top rod?
Yes, you could use the RG27 on top rod but we recommend RGO.
The RG27 is a latch and rod guard and the RGO is a rod guard only. A latch guard is not needed for top latch, only for bottom latch....
Schlage Commercial » Exit Devices » Touch Bar » 22 Series » Von Duprin | Schlage Commercial » Exit Devices » Touch Bar » 33A/35A Series » Von Duprin | Schlage Commercial » Exit Devices » Touch Bar » 98/99 Series » Von Duprin
Does Von Duprin have a repair department?
Von Duprin and Falcon do not offer repair services for any of its exit devices....
Schlage Commercial » Exit Devices » Cross Bar » 55 Series » Von Duprin | Schlage Commercial » Exit Devices » Cross Bar » 88 Series » Von Duprin | Schlage Commercial » Exit Devices » Touch Bar » 22 Series » Von Duprin | Schlage Commercial » Exit Devices » Touch Bar » 33A/35A Series » Von Duprin | Schlage Commercial » Exit Devices » Touch Bar » 98/99 Series » Von Duprin | Schlage Commercial » Power Supplies » Standard » PS900 Series » Von Duprin | Schlage Commercial » System Components » Electric Strikes » 4000 Series » Von Duprin | Schlage Commercial » System Components » Electric Strikes » 5100 Series » Von Duprin | Schlage Commercial » System Components » Electric Strikes » 6000 Series » Von Duprin | Schlage Commercial » System Components » Electric Strikes » 6300 Series » Von Duprin
What exit devices are available for 2' 0" wide doors?
We can build 33/3527A/F, 33/3547A/F, 98/9927/F, and 98/9947/F exit devices for 2 feet wide doors.
Please note: therse are all vertical rod type devices.
Because options within the exit...
Schlage Commercial » Exit Devices » Touch Bar » 33A/35A Series » Von Duprin | Schlage Commercial » Exit Devices » Touch Bar » 98/99 Series » Von Duprin
Why is my Von Duprin QEL light flashing red and green?
Check to make sure there is no bind of the latch....
Schlage Commercial » Exit Devices » Touch Bar » 33A/35A Series » Von Duprin | Schlage Commercial » Exit Devices » Touch Bar » 98/99 Series » Von Duprin | Schlage Commercial » Power Supplies » Standard » PS900 Series » Von Duprin