What is the minimum size door requirement for a 2227?
2227-3 feet on pairs of doors with 5/8" stops can be field sized to fit a 26" minimum door opening.  2227-4 feet devices on pairs of doors can be field sized to fit as low as ...
Schlage Commercial » Exit Devices » Touch Bar » 22 Series » Von Duprin
What is the minimum stile required for the Von Duprin 22 rim exit device with the 230 L trim?
The 22 Rim device on single doors can fit a stile width as low as 4 3/8" when used with the standard 299 or 299F strike.  When used with a 1409 on a single door can fit a stile width as low as 3 ...
Schlage Commercial » Exit Devices » Touch Bar » 22 Series » Von Duprin
Can 2227F devices in an existing opening be converted to LBR?
Schlage Commercial » Exit Devices » Touch Bar » 22 Series » Von Duprin | Schlage Commercial » Exit Devices » Touch Bar » 33A/35A Series » Von Duprin | Schlage Commercial » Exit Devices » Touch Bar » 98/99 Series » Von Duprin
What is the difference between normally open and normally closed?
In a push button type switch (RX or LX), in which the contacts remain in one state unless actuated, the contacts can either be normally open (abbreviated "n.o." or "no") until closed by oper...
Schlage Commercial » Exit Devices » Cross Bar » 55 Series » Von Duprin | Schlage Commercial » Exit Devices » Cross Bar » 88 Series » Von Duprin | Schlage Commercial » Exit Devices » Recessed » 94/95 Series INPACT » Von Duprin | Schlage Commercial » Exit Devices » Touch Bar » 19 Series » Falcon | Schlage Commercial » Exit Devices » Touch Bar » 24 Series » Falcon | Schlage Commercial » Exit Devices » Touch Bar » 25 Series » Falcon | Schlage Commercial » Exit Devices » Touch Bar » 22 Series » Von Duprin | Schlage Commercial » Exit Devices » Touch Bar » 33A/35A Series » Von Duprin | Schlage Commercial » Exit Devices » Touch Bar » 98/99 Series » Von Duprin | Schlage Commercial » Mechanical Locks » Cylindrical » ND Series » Schlage | Schlage Commercial » Mechanical Locks » Mortised » L9000 Series » Schlage | Schlage Commercial » Von Duprin
What strike do I use with a Von Duprin rim device on a pair of doors with flush bolts?
NON Fire Rated doors would use the 1609 strike applied to the inactive leaf with flushbolts.  This may NOT be used on Fire Rated openings....
Schlage Commercial » Exit Devices » Touch Bar » 22 Series » Von Duprin | Schlage Commercial » Exit Devices » Touch Bar » 33A/35A Series » Von Duprin | Schlage Commercial » Exit Devices » Touch Bar » 98/99 Series » Von Duprin
Is a switch required to operate the Von Duprin ALK unit?
Yes.  The exit alarm ALK is shipped standard with a RX, request to exit switch, but can work with the optional LX, latch bolt monitor switch.  If there is no switch in the device it will never alarm...
Schlage Commercial » Exit Devices » Touch Bar » 22 Series » Von Duprin | Schlage Commercial » Exit Devices » Touch Bar » 98/99 Series » Von Duprin
What is SLM blocking and how does it effect exit device installation?
SLM - special laminated material - blocking is put into the wood doors so there is material to mount the exit device using wood screws....
Schlage Commercial » Exit Devices » Touch Bar » 24 Series » Falcon | Schlage Commercial » Exit Devices » Touch Bar » 25 Series » Falcon | Schlage Commercial » Exit Devices » Touch Bar » 22 Series » Von Duprin | Schlage Commercial » Exit Devices » Touch Bar » 33A/35A Series » Von Duprin | Schlage Commercial » Exit Devices » Touch Bar » 98/99 Series » Von Duprin
Is the 2227 panic exit device available LBR?
The Von Duprin 2227 or 2227-F  exit device is available less bottom rod.  Specify 2227-LBR or 2227F-LBR for fire....
Schlage Commercial » Exit Devices » Touch Bar » 22 Series » Von Duprin
Does Von Duprin have a fire latch that will go into the floor?
Auxiliary fire latch is tested only from door to door latching by Von Duprin. Some door manufacturers have tested our devices LBR and use additional fire latches to pass the fire test. Contact the doo...
Schlage Commercial » Exit Devices » Touch Bar » 22 Series » Von Duprin | Schlage Commercial » Exit Devices » Touch Bar » 33A/35A Series » Von Duprin | Schlage Commercial » Exit Devices » Touch Bar » 98/99 Series » Von Duprin
Can a Von Duprin 3' pushpad exit device be converted to a 4' device in the field?
A 3' exit device cannot be converted to a 4' exit device. You will need to replace the 3' device with a 4'. Conversely, a 4' device cannot be converted to a 3' device. Converting these exit devic...