What cylinder do I use with Monarch key-in-lever (KIL) trim?
        
        
                            The Monarch KIL (key-in-lever) trim uses the following cylinders:Schlage Cylinders23-013: Conventional20-750: Primus20-750-XP: Primus XP20-550: Primus UL43720-550-XP: Primus UL437 XPFalcon CylinderA23...                    
        
                        Schlage Commercial » Exit Devices » Touch Bar » 19 Series » Falcon | Schlage Commercial » Key Systems » Cylinder Category » Falcon | Schlage Commercial » Key Systems » Cylinder Mechanism » Schlage | Schlage Commercial » Key Systems » Cylinders » Cylinder » Falcon        
     
    
                
            Can 912L be re-handed in the field?
        
        
                            The 912L trims produced after 2/28/2011 can be re-handed in the field. See appropriate 912L instructions at 912L instructions for trims after 2/28/2011 For 912L instructions on trims pr...                    
        
                        Schlage Commercial » Exit Devices » Touch Bar » 19 Series » Falcon        
     
    
                
            What is the part number for the former F588 from Monarch?
        
        
                            The top latch for a Fire rated surface vertical rod device is part #650375-00 which replaced the old part #F588....                    
        
                        Schlage Commercial » Exit Devices » Cross Bar » XX Series » Falcon | Schlage Commercial » Exit Devices » Touch Bar » 18 Series » Falcon | Schlage Commercial » Exit Devices » Touch Bar » 19 Series » Falcon | Schlage Commercial » Exit Devices » Touch Bar » 24 Series » Falcon | Schlage Commercial » Exit Devices » Touch Bar » 25 Series » Falcon        
     
    
                
            How do I rekey a 914KIL trim?
        
        
                            The method to re-key is to unscrew the cap on the back(914KIL cylinder picture), insert the key & turn 90 degrees, and then push the plug out with a follower bar slowly. The plug will have al...                    
        
                        Schlage Commercial » Exit Devices » Touch Bar » 19 Series » Falcon        
     
    
                
            What is the conversion for Monarch BA?
        
        
                            In 2007 Monarch part numbers went through a conversion as described below.
OLD
NEW
DESCRIPTION
BA
EO
Exit Only, No Outside Trim
DT
no change
-
PULL ONLY
DT
Dummy Trim...                    
        
                        Schlage Commercial » Exit Devices » Cross Bar » XX Series » Falcon | Schlage Commercial » Exit Devices » Touch Bar » 17 Series » Falcon | Schlage Commercial » Exit Devices » Touch Bar » 18 Series » Falcon | Schlage Commercial » Exit Devices » Touch Bar » 19 Series » Falcon        
     
    
                
            What would the 904H stand for on a Falcon  Monarch exit device?
        
        
                            The "904H" is a UL Panic label that is placed on the centercase of the Falcon/Monarch Panic device....                    
        
                        Schlage Commercial » Exit Devices » Touch Bar » 17 Series » Falcon | Schlage Commercial » Exit Devices » Touch Bar » 18 Series » Falcon | Schlage Commercial » Exit Devices » Touch Bar » 19 Series » Falcon | Schlage Commercial » Exit Devices » Touch Bar » 24 Series » Falcon | Schlage Commercial » Exit Devices » Touch Bar » 25 Series » Falcon        
     
    
    
                
            What is the difference between normally open and normally closed?
        
        
                            In a push button type switch (RX or LX), in which the contacts remain in one state unless actuated, the contacts can either be normally open (abbreviated "n.o." or "no") until closed by oper...                    
        
                        Schlage Commercial » Exit Devices » Cross Bar » 55 Series » Von Duprin | Schlage Commercial » Exit Devices » Cross Bar » 88 Series » Von Duprin | Schlage Commercial » Exit Devices » Recessed » 94/95 Series INPACT » Von Duprin | Schlage Commercial » Exit Devices » Touch Bar » 19 Series » Falcon | Schlage Commercial » Exit Devices » Touch Bar » 24 Series » Falcon | Schlage Commercial » Exit Devices » Touch Bar » 25 Series » Falcon | Schlage Commercial » Exit Devices » Touch Bar » 22 Series » Von Duprin | Schlage Commercial » Exit Devices » Touch Bar » 33A/35A Series » Von Duprin | Schlage Commercial » Exit Devices » Touch Bar » 98/99 Series » Von Duprin | Schlage Commercial » Mechanical Locks » Cylindrical » ND Series | Schlage Commercial » Mechanical Locks » Mortised » L9000 Series | Schlage Commercial » Von Duprin        
     
    
                
            What cylinder is used in the Falcon 24/25 exit alarm kit?
        
        
                            The Exit Alarm takes a 1 1/8" Mortise cylinder with a straight cam. See first page of Exit Alarm inst below.
Exit Alarm inst...                    
        
                        Schlage Commercial » Exit Devices » Touch Bar » 19 Series » Falcon | Schlage Commercial » Exit Devices » Touch Bar » 24 Series » Falcon | Schlage Commercial » Exit Devices » Touch Bar » 25 Series » Falcon        
     
    
                
            What keyway or section is shipped with the 914 KIL-IC?
        
        
                            The 914KIL-IC trim is shipped with a Small format interchangeable core (SFIC) in a 6 pin "A" section/keyway.  A comparable core from Falcon would be the C646 (uncombinated - no pins) or C606...                    
        
                        Schlage Commercial » Exit Devices » Touch Bar » 19 Series » Falcon | Schlage Commercial » Key Systems » Cylinder Category » Falcon