What is the part number for QEL94/95 inpact conversion kit?
The part will be configured as CONVERT.XXXX part numbers. The customer need to specify the following criteria.
Required: Series 94 or 95, Fire or Panic , 3 feet/4feet or 2 feet 6 inches/2 feet...
Schlage Commercial » Exit Devices » Recessed » 94/95 Series INPACT » Von Duprin
Can you use a Von Duprin 94/95 Inpact device on a wood door?
The Von Duprin 94/95 series Inpact devices can only be installed on metal doors as there would not be enough material left in the wood door after cutting out the 94/95 device prep to maintain door str...
Schlage Commercial » Exit Devices » Recessed » 94/95 Series INPACT » Von Duprin
What is the size of the current Von Duprin dogging key?
All Von Duprin exit devices (22, 33/35A ,55 ,88 ,95 and 98/99) use 5/32" dogging key.
There are two part numbers available: 090005 is the package of 2 and 090085 is the package of 10....
Schlage Commercial » Exit Devices » Cross Bar » 55 Series » Von Duprin | Schlage Commercial » Exit Devices » Cross Bar » 88 Series » Von Duprin | Schlage Commercial » Exit Devices » Recessed » 94/95 Series INPACT » Von Duprin | Schlage Commercial » Exit Devices » Touch Bar » 22 Series » Von Duprin | Schlage Commercial » Exit Devices » Touch Bar » 33A/35A Series » Von Duprin | Schlage Commercial » Exit Devices » Touch Bar » 98/99 Series » Von Duprin
How do I identify the new QEL motor launched in 2012?
The new QEL motor has a label affixed to the cover, the older QEL motor has no such label. See attached image....
Schlage Commercial » Exit Devices » Recessed » 94/95 Series INPACT » Von Duprin | Schlage Commercial » Exit Devices » Touch Bar » 33A/35A Series » Von Duprin | Schlage Commercial » Exit Devices » Touch Bar » 98/99 Series » Von Duprin | Schlage Commercial » Von Duprin
What does chattering mean on a QEL?
If a vertical rod device, verify the vertical rods are adjusted properly and there is not a bind at the strikes.
Make sure the push bar is not binding at the pushbar guides or any ot...
Schlage Commercial » Exit Devices » Recessed » 94/95 Series INPACT » Von Duprin | Schlage Commercial » Exit Devices » Touch Bar » 33A/35A Series » Von Duprin | Schlage Commercial » Exit Devices » Touch Bar » 98/99 Series » Von Duprin | Schlage Commercial » Von Duprin
Why is the output cam breaking on the 940L?
The most common cause is the position of the master cam on the 94/9547 or 94/9575 is not in the neutral position.
To change the position of the cam:
Remove set screw...
Schlage Commercial » Exit Devices » Recessed | Schlage Commercial » Exit Devices » Recessed » 94/95 Series INPACT | Schlage Commercial » Exit Devices » Recessed » 94/95 Series INPACT » Von Duprin | Schlage Commercial » Von Duprin