How long should programming new door files into an AD-Series or Co-Series offline locks take?
To improve door programming file speed, upgrade your SUS to version 4.1.0 or higher...
Schlage Commercial » Electronic Locks » Hand Held Devices » HHD » Schlage Electronics | Schlage Commercial » Electronic Locks » Networked » AD 400 Series » Schlage Electronics | Schlage Commercial » Electronic Locks » Offline » AD 200 Series » Schlage Electronics | Schlage Commercial » Electronic Locks » Offline » CO 200 Series » Schlage Electronics
Resetting the AD400 Lock to factory default settings
Level 1 (FDR) Factory Default reset1. Remove the top inside cover. 2. Press and hold Schlage button on the reader wait for (2) beeps and (2) green flashes (appx 10 seconds). 3. Release the Schlage b...
Schlage Commercial » Electronic Locks » Networked » AD 400 Series » Schlage Electronics | Schlage Commercial » Electronic Locks » Offline » AD 200 Series » Schlage Electronics
Schlage Utility Software (SUS) is not synchronizing door file information when connected to the lock
When synchronizing door files to the HHD  ensure that the SUS is not running.Make certain the proper sync folder location is properly configured in the Schlage express softwareVerify cable proper...
Schlage Commercial » Electronic Locks » Networked » AD 400 Series » Schlage Electronics | Schlage Commercial » Electronic Locks » Offline » AD 200 Series » Schlage Electronics | Schlage Commercial » Electronic Locks » Offline » CM Series » Schlage Electronics | Schlage Commercial » Electronic Locks » Offline » CO 200 Series » Schlage Electronics | Schlage Commercial » Schlage
What current should an AD-Series or CO-Series lockset draw while in its low power "Sleep" mode?
Use a multi-meter in series with the batteries to measure battery current.  Be sure your multi-meter can accurately measure very low current, in the micro-amp range. See the attached Technical Note:...
Schlage Commercial » Electronic Locks » Networked » AD 400 Series » Schlage Electronics | Schlage Commercial » Electronic Locks » Offline » AD 200 Series » Schlage Electronics | Schlage Commercial » Electronic Locks » Offline » CO 100 Series » Schlage Electronics | Schlage Commercial » Electronic Locks » Offline » CO 200 Series » Schlage Electronics | Schlage Commercial » Electronic Locks » Offline » CO 250 Series » Schlage Electronics
Why can't I order an AD-Series or CO-Series mortise deadbolt with a classroom/storeroom (70) function
* NOTE: the AD300/400 devices simply communicate the change in Deadbolt Position status to the Host software.  The software then decides what action should or should not be taken at the device. ...
Schlage Commercial » Electronic Locks » Networked » AD 400 Series » Schlage Electronics | Schlage Commercial » Electronic Locks » Offline » AD 200 Series » Schlage Electronics | Schlage Commercial » Electronic Locks » Offline » CO 200 Series » Schlage Electronics
AD200 40 Function won't go into privacy
Make sure inside cover is on. If the tamper switch is open, the privacy will not engage....
Schlage Commercial » Electronic Locks » Networked » AD 400 Series » Schlage Electronics | Schlage Commercial » Electronic Locks » Offline » AD 200 Series » Schlage Electronics
What are the dimensions of AD-400?
15 tall x 3.5 wide...
Schlage Commercial » Electronic Locks » Networked » AD 400 Series » Schlage Electronics | Schlage Commercial » Electronic Locks » Offline » AD 200 Series » Schlage Electronics
Why dosen't my AD or CO Series exit trim (993) lever rotate in both directions
 Opposite rotation of the lever is intentionally restricted by an internal block device in the spring cage this is normal operation....
Schlage Commercial » Electronic Locks » Networked » AD 400 Series » Schlage Electronics | Schlage Commercial » Electronic Locks » Offline » AD 200 Series » Schlage Electronics | Schlage Commercial » Electronic Locks » Offline » CO 100 Series » Schlage Electronics | Schlage Commercial » Electronic Locks » Offline » CO 200 Series » Schlage Electronics | Schlage Commercial » Electronic Locks » Offline » CO 250 Series » Schlage Electronics
What finishes are available on the decorative plate for AD / CO
Available Finishes: 626 Satin Chrome Standard. Please consult Customer Care for 605 Bright Brass or 643E Aged Bronze.Click - for data sheet for AD 400, includes pictures of all finishes for AD Se...
Schlage Commercial » Electronic Locks » Networked » AD 400 Series » Schlage Electronics | Schlage Commercial » Electronic Locks » Offline » AD 200 Series » Schlage Electronics | Schlage Commercial » Electronic Locks » Offline » CO 200 Series » Schlage Electronics
For the Offline locks AD-200, AD-250 and CO-200 what is the purpose of the coin cell.
The coin cell maintains the real time clock on offline locks. This allow for accurate execution of timed functions. If all AA battery and Coin cell battery power is lost, when AD-200/AD-250/CO-2...
Schlage Commercial » Electronic Locks » Offline » AD 200 Series » Schlage Electronics | Schlage Commercial » Electronic Locks » Offline » CO 200 Series » Schlage Electronics