How many Time Zone Intervals can I have on an Offline Lock?
The only way you can have more than one Time Zone Interval is when the Time spans midnight....
Schlage Commercial » Electronic Locks » Offline » AD 200 Series » Schlage Electronics | Schlage Commercial » Electronic Locks » Offline » AD 250 Series » Schlage Electronics | Schlage Commercial » Electronic Locks » Offline » CL Series » Schlage Electronics | Schlage Commercial » Electronic Locks » Offline » CM Series » Schlage Electronics
What is the low battery threshold for the AD and CO Locks?
CO200 & CO250 Disable coin cell Nuisance delay and blink,
With CO.A.7 and SUS 4.10.2 or newer for CO200 and CO250, you can use the SUS/HHD, under Lock Properties, Edit, to de-select, DISABLE, t...
Schlage Commercial » Electronic Locks » Networked » AD 300 Series » Schlage Electronics | Schlage Commercial » Electronic Locks » Networked » AD 400 Series » Schlage Electronics | Schlage Commercial » Electronic Locks » Offline » AD 200 Series » Schlage Electronics | Schlage Commercial » Electronic Locks » Offline » CO 100 Series » Schlage Electronics | Schlage Commercial » Electronic Locks » Offline » CO 200 Series » Schlage Electronics | Schlage Commercial » Electronic Locks » Offline » CO 250 Series » Schlage Electronics
Where do I put the Active Sync directory path so that my door files are sync with my PDA on Schlage Express?
To change your Program Files folder for SMS Express
Open Schlage Express go to Settings and select Program Settings.
Go to the Programming tab Click on Locks will be programmed with a Pockect PC ...
Schlage Commercial » Electronic Locks » Offline » AD 200 Series » Schlage Electronics | Schlage Commercial » Electronic Locks » Offline » AD 250 Series » Schlage Electronics | Schlage Commercial » Electronic Locks » Offline » CL Series » Schlage Electronics | Schlage Commercial » Electronic Locks » Offline » CM Series » Schlage Electronics | Schlage Commercial » Security Management » Schlage Electronics | Schlage Commercial » Software » Schlage Express » Software » Schlage Electronics
Coincell Battery Low Battery Voltage
Coincell is considered low at 2.7v. At this voltage, the unit won't be able to maintain the real time clock in the lockset when the double A batteries are removed or replaced. Need to replace coincell...
Schlage Commercial » Electronic Locks » Networked » AD 400 Series » Schlage Electronics | Schlage Commercial » Electronic Locks » Offline » AD 200 Series » Schlage Electronics | Schlage Commercial » Electronic Locks » Offline » CO 200 Series » Schlage Electronics
What is the power requirements for the CT5000 / WRI400?
12.0VDC or 24VDC with current rating of at least 0.5 amp (500ma)....
Schlage Commercial » Electronic Locks » Networked » AD 400 Series » Schlage Electronics | Schlage Commercial » Electronic Locks » Offline » AD 200 Series » Schlage Electronics
Can a CT5000 power a Reader?
No, there is no power connection for the reader on the WRI400. Customers should provide reader power seperately....
Schlage Commercial » Electronic Locks » Networked » AD 400 Series » Schlage Electronics | Schlage Commercial » Electronic Locks » Offline » AD 200 Series » Schlage Electronics
Is the Schlage Utility Software backwards compatible with legacy Schlage products?
Supported Devices
AD Series Locks
AD-200 &n...
Schlage Commercial » Electronic Locks » Hand Held Devices » HHD » Schlage Electronics | Schlage Commercial » Electronic Locks » Networked » AD 400 Series » Schlage Electronics | Schlage Commercial » Electronic Locks » Networked » VIP Series » Schlage Electronics | Schlage Commercial » Electronic Locks » Networked » WA Series » Schlage Electronics | Schlage Commercial » Electronic Locks » Offline » AD 200 Series » Schlage Electronics | Schlage Commercial » Electronic Locks » Offline » CL Series » Schlage Electronics | Schlage Commercial » Electronic Locks » Offline » CM Series » Schlage Electronics | Schlage Commercial » Electronic Locks » Offline » King Cobra Series » Schlage Electronics | Schlage Commercial » Mechanical Locks » Portable » CL Series » Schlage | Schlage Commercial » Schlage
Can the AD-200 and CO-200 be manually programmed?
Yes. The AD-200 and CO-200 each can be managed through manual direct lock keypad programming or PC software programming using an HHD to transfer programming information to the lock.
T...
Schlage Commercial » Electronic Locks » Offline » AD 200 Series » Schlage Electronics | Schlage Commercial » Electronic Locks » Offline » CO 200 Series » Schlage Electronics
What causes the error "Device does not support this action - E802" when I'm coupling an AD lock?
In order to properly couple, the interior pushbutton must be held down while tapping the SW1 (tamper switch) three times. This will enable the lock to couple to the HHD....
Schlage Commercial » Electronic Locks » Hand Held Devices » HHD » Schlage Electronics | Schlage Commercial » Electronic Locks » Networked » AD 300 Series » Schlage Electronics | Schlage Commercial » Electronic Locks » Networked » AD 400 Series » Schlage Electronics | Schlage Commercial » Electronic Locks » Offline » AD 200 Series » Schlage Electronics