Can the PIM485 work with legacy wireless devices
No, the current PIM400 is NOT backward compatible with the legacy Wireless lock products.The legacy PIM is also NOT forward compatible with the AD400 lock product. ...
Schlage Commercial » Electronic Locks » Networked » WA Series » Schlage Electronics
Linking a PIM-TD2 / PIM-TD4 to a WRI
Note: Too many dropped packets will result in link failure. Link fail is reported with rapid green red alternating on LED2.
A good link will terminate the packet ...
Schlage Commercial » Electronic Locks » Networked » WA Series » Schlage Electronics
What is the maximum number of users on an AD-200 lock
AD-200 5000 users, 5000 audits
CO-100 500 users
CO-200 2000 users 2000 audits
KC-2 1000 users, 1000 audits
CM (Silver) 1000 users, 1000 audits...
Schlage Commercial » Electronic Locks » Networked » AD 400 Series » Schlage Electronics | Schlage Commercial » Electronic Locks » Networked » VIP Series » Schlage Electronics | Schlage Commercial » Electronic Locks » Networked » WA Series » Schlage Electronics | Schlage Commercial » Electronic Locks » Offline » AD 200 Series » Schlage Electronics | Schlage Commercial » Electronic Locks » Offline » CL Series » Schlage Electronics | Schlage Commercial » Electronic Locks » Offline » CM Series » Schlage Electronics | Schlage Commercial » Electronic Locks » Offline » CO 200 Series » Schlage Electronics | Schlage Commercial » Electronic Locks » Offline » King Cobra Series » Schlage Electronics
How to link CDT to PIM-485
Hold down 'reset' and 'SA' buttons at the same time, let go of 'reset' and continue to hold down 'SA' until CR10, CR7 start flashing Red rapidly, then release SA and CDT should show message "PIM is co...
Schlage Commercial » Electronic Locks » Networked » WA Series » Schlage Electronics
How does Cache mode work on AD400 and AD300 locksets?
An AD400 granting credentials access in “cache mode” will blink the Schlage with the normal green LED, followed by a brief red Schlage LED flash, indicating no RF communication and access was gran...
Schlage Commercial » Electronic Locks » Hand Held Devices » HHD » Schlage Electronics | Schlage Commercial » Electronic Locks » Networked » AD 300 Series » Schlage Electronics | Schlage Commercial » Electronic Locks » Networked » AD 400 Series » Schlage Electronics | Schlage Commercial » Electronic Locks » Networked » WA Series » Schlage Electronics | Schlage Commercial » Electronic Locks » Offline » AD 200 Series » Schlage Electronics
Can AA dry cells be used for the WA5296 battery packs
No the batteries a specific rechargeable type and must be factory welded to connect them. The battery pack is part number K380-001...
Schlage Commercial » Electronic Locks » Networked » WA Series » Schlage Electronics
PIM COMPATIBILITY
No, the AD400 / WRI400/ WPR400 only work with the PIM 400-485 or PIM 400-TD2. The legacy WA locks / WRI / WPR2/ WSM only communicate with the legacy PIM-485 or PIM-TD2....
Schlage Commercial » Electronic Locks » Networked » AD 400 Series » Schlage Electronics | Schlage Commercial » Electronic Locks » Networked » WA Series » Schlage Electronics
What type of cable do I need to use to connect my devices?
CDT to Legacy Pim: requires a Straight thru serial connectionCIP to PC: requires a null modem connectionLegacy CRP to PC : requires a null modem connectionLegacy CRM to PC : re...
Schlage Commercial » Electronic Locks » Networked » WA Series » Schlage Electronics | Schlage Commercial » Electronic Locks » Offline » CM Series » Schlage Electronics | Schlage Commercial » Electronic Locks » Offline » King Cobra Series » Schlage Electronics | Schlage Commercial » Software » Schlage Express » Software » Schlage Electronics