Adding locks to Legacy PIB-4D- additional locks not recognized.
When adding another door to the legacy PIB-4d, You must change the S1 dipswitches 11 & 12 Number         Dip11  Dip12     of lock...
Schlage Commercial » Electronic Locks » Networked » VIP Series » Schlage Electronics
Providing Seperate Power To The PIB board
When powering a PIB independent of the ACP supply the ground of the supplies must be made common.This ensures a common reference for the weigand output signals. Failure to do so may result in unreliab...
Schlage Commercial » Electronic Locks » Networked » VIP Series » Schlage Electronics
Is the Schlage Utility Software backwards compatible with legacy Schlage products?
Supported Devices AD Series Locks AD-200                          &n...
Schlage Commercial » Electronic Locks » Hand Held Devices » HHD » Schlage Electronics | Schlage Commercial » Electronic Locks » Networked » AD 400 Series » Schlage Electronics | Schlage Commercial » Electronic Locks » Networked » VIP Series » Schlage Electronics | Schlage Commercial » Electronic Locks » Networked » WA Series » Schlage Electronics | Schlage Commercial » Electronic Locks » Offline » AD 200 Series » Schlage Electronics | Schlage Commercial » Electronic Locks » Offline » CL Series » Schlage Electronics | Schlage Commercial » Electronic Locks » Offline » CM Series » Schlage Electronics | Schlage Commercial » Electronic Locks » Offline » King Cobra Series » Schlage Electronics | Schlage Commercial » Mechanical Locks » Portable » CL Series » Schlage | Schlage Commercial » Schlage
What is the current draw of a CT-5000
500mA at 12 or 24 VDC...
Schlage Commercial » Electronic Locks » Networked » VIP Series » Schlage Electronics
What is the maximum number of users on an AD-200 lock
AD-200 5000 users, 5000 audits CO-100 500 users CO-200 2000 users 2000 audits KC-2 1000 users, 1000 audits CM (Silver) 1000 users, 1000 audits...
Schlage Commercial » Electronic Locks » Networked » AD 400 Series » Schlage Electronics | Schlage Commercial » Electronic Locks » Networked » VIP Series » Schlage Electronics | Schlage Commercial » Electronic Locks » Networked » WA Series » Schlage Electronics | Schlage Commercial » Electronic Locks » Offline » AD 200 Series » Schlage Electronics | Schlage Commercial » Electronic Locks » Offline » CL Series » Schlage Electronics | Schlage Commercial » Electronic Locks » Offline » CM Series » Schlage Electronics | Schlage Commercial » Electronic Locks » Offline » CO 200 Series » Schlage Electronics | Schlage Commercial » Electronic Locks » Offline » King Cobra Series » Schlage Electronics
The data rate of the PIB-300
The Bit rate/Baud rate is 9600....
Schlage Commercial » Electronic Locks » Networked » VIP Series » Schlage Electronics
What is the right way to use multiple PIM400 on the same Bright Blue channel?
Set PIM400 Address   The SUS is used to set the address of the PIM400. The address of the PIM should be set to the lowest number available, from 0 to 15. A maximum of sixteen (16) AD-400 Locks ca...
Schlage Commercial » Electronic Locks » Networked » AD 300 Series » Schlage Electronics | Schlage Commercial » Electronic Locks » Networked » AD 400 Series » Schlage Electronics | Schlage Commercial » Electronic Locks » Networked » VIP Series » Schlage Electronics | Schlage Commercial » Security Management » Schlage Electronics
Reset PIB300
Press and hold both link buttons for 3 seconds...
Schlage Commercial » Electronic Locks » Networked » VIP Series » Schlage Electronics
Lock address settings for legacy Schlage / Locknetics PIBs
Lock Address Settings   Dipswitch 1 LOCK 2LOCKS 3LOCKS 4LOCKS 11 OFF ON OFF ON 12 OFF OFF ON ON 13 MUST BE SET TO OFF   ...
Schlage Commercial » Electronic Locks » Networked » VIP Series » Schlage Electronics
How to address a Schlage / Locknetics VIP legacy lock
Lock Dip switch settings: DIP SWITCH SETTINGS 1 2 3 4 OFF OFF OFF OFF Lock Address: 01 (RSI, INTERFLEX, VIP) ON OFF OFF OFF Lock Addres...