Will 1 7/16" thick glass require a special rabbet size on borrowed light frames?
Yes. 1 7/16" thick glass but a special rabbet size is required. The size of rabbet required for the frames would depend on the size of the glazing bead being used. For 1" wide glazing stops, a m...
Schlage Commercial » Doors and Frames » Frames » F & FN Series » Steelcraft | Schlage Commercial » Doors and Frames » Frames » Frame Elevations » Steelcraft | Schlage Commercial » Doors and Frames » Frames » MU Series » Steelcraft | Schlage Commercial » Steelcraft
Can Drywall Slip-on frames be welded?
Drywall Slip-on frames are recommended and designed to be installed as KD (Knock Down) assemblies and not recommended to be welded (SUA). If a DW-Series or K-Series is welded prior to installatio...
Schlage Commercial » Doors and Frames » Frames » DW & K Series » Steelcraft | Schlage Commercial » Doors and Frames » Frames » MU Series » Steelcraft | Schlage Commercial » Steelcraft
Where is the Fire Label located on a door and a frame?
Fire labels (UL, ITS/WHI or FM) are located as follows: Butt Hinges and Pivots: On the doors the fire label is located on the hinge edge between the top and 2nd hinge preparation. On the frames ...
Schlage Commercial » Doors and Frames » Doors » A14 Series » Steelcraft | Schlage Commercial » Doors and Frames » Doors » B Series » Steelcraft | Schlage Commercial » Doors and Frames » Doors » CE Series » Steelcraft | Schlage Commercial » Doors and Frames » Doors » H Series » Steelcraft | Schlage Commercial » Doors and Frames » Doors » L-Series » Steelcraft | Schlage Commercial » Doors and Frames » Doors » Paladin PW Series » Steelcraft | Schlage Commercial » Doors and Frames » Doors » SL Series » Steelcraft | Schlage Commercial » Doors and Frames » Doors » T Series » Steelcraft | Schlage Commercial » Doors and Frames » Frames » DW & K Series » Steelcraft | Schlage Commercial » Doors and Frames » Frames » F & FN Series » Steelcraft | Schlage Commercial » Doors and Frames » Frames » FE & DE Series » Steelcraft | Schlage Commercial » Doors and Frames » Frames » MU Series » Steelcraft | Schlage Commercial » Steelcraft
Can an additional jamb anchor be used as a base anchor on fire rated frames?
Yes, an additional jamb anchor can be used at the bottom of the frame in lieu of the typical (adjustable or weld-in) base anchor in fire rated frames. This is limited to the anchor designed for u...
Schlage Commercial » Doors and Frames » Frames » F & FN Series » Steelcraft | Schlage Commercial » Doors and Frames » Frames » FE & DE Series » Steelcraft | Schlage Commercial » Doors and Frames » Frames » MU Series » Steelcraft | Schlage Commercial » Steelcraft
Are hospital stops approved on fire rated frames?
Yes, hospital stops are available on fire rated frames. Maximum approval = 3 hour Maximum sizes:  singles up to 4'0" x 8'0" pairs up to 8'0" x 8'0" Maximum hospital stop height 6" from botto...
Schlage Commercial » Doors and Frames » Frames » DW & K Series » Steelcraft | Schlage Commercial » Doors and Frames » Frames » F & FN Series » Steelcraft | Schlage Commercial » Doors and Frames » Frames » FE & DE Series » Steelcraft | Schlage Commercial » Doors and Frames » Frames » MU Series » Steelcraft | Schlage Commercial » Steelcraft
What is the standard screw size used on Steelcraft doors with 4 1/2" or 5" hinges?
Steelcraft follows the industry standards for hinge reinforcement and preparation for both door and frame. Unless otherwise specified all products prepared for butt hinges will have mounting holes dr...
Schlage Commercial » Doors and Frames » Doors » A14 Series » Steelcraft | Schlage Commercial » Doors and Frames » Doors » B Series » Steelcraft | Schlage Commercial » Doors and Frames » Doors » CE Series » Steelcraft | Schlage Commercial » Doors and Frames » Doors » H Series » Steelcraft | Schlage Commercial » Doors and Frames » Doors » L-Series » Steelcraft | Schlage Commercial » Doors and Frames » Doors » Paladin PW Series » Steelcraft | Schlage Commercial » Doors and Frames » Doors » SL Series » Steelcraft | Schlage Commercial » Doors and Frames » Doors » T Series » Steelcraft | Schlage Commercial » Doors and Frames » Frames » DW & K Series » Steelcraft | Schlage Commercial » Doors and Frames » Frames » F & FN Series » Steelcraft | Schlage Commercial » Doors and Frames » Frames » FE & DE Series » Steelcraft | Schlage Commercial » Doors and Frames » Frames » MU Series » Steelcraft
What is Steelcraft's standard hinge locations for a 6'8" high frame from head to top of each hinge?
The location to the top of hinge will vary depending on hinge size used. 6'8" Frame with 1 1/2 pair of hinges (top to top): For 4 1/2" hinges from the head to top of each hinge is 7 1/2", 37 7/1...
Schlage Commercial » Doors and Frames » Frames » DW & K Series » Steelcraft | Schlage Commercial » Doors and Frames » Frames » F & FN Series » Steelcraft | Schlage Commercial » Doors and Frames » Frames » FE & DE Series » Steelcraft | Schlage Commercial » Doors and Frames » Frames » MU Series » Steelcraft
What is the maximum glass light size available on a 20 minute sidelight frame?
On fire rated transom and/or sidelight frames and fire rated window frames, Steelcraft labeling procedures only control the O/A width and/or height of the frames based on wall condition. The amount of...
Schlage Commercial » Doors and Frames » Frames » F & FN Series » Steelcraft | Schlage Commercial » Doors and Frames » Frames » Frame Elevations » Steelcraft | Schlage Commercial » Doors and Frames » Frames » MU Series » Steelcraft
How are Butt Hinges located?
Steelcraft locates all butt hinges from the top of the door to the centerline of each hinge as standard practice: Locating hinges to the center line of the hinge keeps all hinge locations the...
Schlage Commercial » Doors and Frames » Doors » A14 Series » Steelcraft | Schlage Commercial » Doors and Frames » Doors » B Series » Steelcraft | Schlage Commercial » Doors and Frames » Doors » CE Series » Steelcraft | Schlage Commercial » Doors and Frames » Doors » H Series » Steelcraft | Schlage Commercial » Doors and Frames » Doors » L-Series » Steelcraft | Schlage Commercial » Doors and Frames » Doors » SL Series » Steelcraft | Schlage Commercial » Doors and Frames » Doors » T Series » Steelcraft | Schlage Commercial » Doors and Frames » Frames » DW & K Series » Steelcraft | Schlage Commercial » Doors and Frames » Frames » F & FN Series » Steelcraft | Schlage Commercial » Doors and Frames » Frames » FE & DE Series » Steelcraft | Schlage Commercial » Doors and Frames » Frames » MU Series » Steelcraft | Schlage Commercial » Steelcraft
Does Steelcraft offer the doors and frames galvanized or galvannealed?
Yes, Steelcraft does offer optional A60 and A40 Galvannealed, and G90 Galvanized steel on doors and frames. Galvannealed A60 and A40: A60 coating designation - optional on all doors and frames. ...
Schlage Commercial » Doors and Frames » Doors » A14 Series » Steelcraft | Schlage Commercial » Doors and Frames » Doors » B Series » Steelcraft | Schlage Commercial » Doors and Frames » Doors » CE Series » Steelcraft | Schlage Commercial » Doors and Frames » Doors » H Series » Steelcraft | Schlage Commercial » Doors and Frames » Doors » L-Series » Steelcraft | Schlage Commercial » Doors and Frames » Doors » Paladin PW Series » Steelcraft | Schlage Commercial » Doors and Frames » Doors » SL Series » Steelcraft | Schlage Commercial » Doors and Frames » Doors » T Series » Steelcraft | Schlage Commercial » Doors and Frames » Frames » DW & K Series » Steelcraft | Schlage Commercial » Doors and Frames » Frames » F & FN Series » Steelcraft | Schlage Commercial » Doors and Frames » Frames » FE & DE Series » Steelcraft | Schlage Commercial » Doors and Frames » Frames » MU Series » Steelcraft | Schlage Commercial » Steelcraft