Category: Steelcraft

(Results from 1 to 10)
Are Steelcraft doors and/or frames fire rated?
Yes, Steelcraft doors and/or frames are available and can carry a UL, WH or FM label. The type of fire label (UL, WH or FM) is dictated by the specifications and local building code. Doors and...
Schlage Commercial » Doors and Frames » Doors » A14 Series » Steelcraft | Schlage Commercial » Doors and Frames » Doors » B Series » Steelcraft | Schlage Commercial » Doors and Frames » Doors » CE Series » Steelcraft | Schlage Commercial » Doors and Frames » Doors » H Series » Steelcraft | Schlage Commercial » Doors and Frames » Doors » L-Series » Steelcraft | Schlage Commercial » Doors and Frames » Doors » SL Series » Steelcraft | Schlage Commercial » Doors and Frames » Doors » T Series » Steelcraft | Schlage Commercial » Doors and Frames » Frames » DW & K Series » Steelcraft | Schlage Commercial » Doors and Frames » Frames » F & FN Series » Steelcraft | Schlage Commercial » Doors and Frames » Frames » MU Series » Steelcraft | Schlage Commercial » Steelcraft
What is the maximum size of a UL fire rated three (3) sided frame?
Fire Rated three (3) frames are available in the following maximum door opening sizes: F and FN-Series frame:4' 0" X 10' 0" single door opening8' 0" X 10' 0” double door openingMU-Series frame:...
Schlage Commercial » Doors and Frames » Frames » DW & K Series » Steelcraft | Schlage Commercial » Doors and Frames » Frames » F & FN Series » Steelcraft | Schlage Commercial » Doors and Frames » Frames » FE & DE Series » Steelcraft | Schlage Commercial » Doors and Frames » Frames » MU Series » Steelcraft | Schlage Commercial » Steelcraft
What is the maximum size of a ITS/WHI fire rated three (3) sided frame?
ITS/WHI Fire Rated three (3) frames are available in the following maximum door opening sizes:F and FN-Series:4' 0" X 10' 0" single door8' 0" X 10' 0” double door or pairsMU-Series:4' 0" X 9' 0" sin...
Schlage Commercial » Doors and Frames » Frames » DW & K Series » Steelcraft | Schlage Commercial » Doors and Frames » Frames » F & FN Series » Steelcraft | Schlage Commercial » Doors and Frames » Frames » FE & DE Series » Steelcraft | Schlage Commercial » Doors and Frames » Frames » MU Series » Steelcraft | Schlage Commercial » Steelcraft
What causes excessive pinhole rust to start showing up on steel frames?
CAUTION must be used in investigating this problem - In most cases, excessive field rusting of products is caused by improper storage at the jobsite. That situation must be validated prior to refusing...
Schlage Commercial » Doors and Frames » Frames » F & FN Series » Steelcraft | Schlage Commercial » Doors and Frames » Frames » MU Series » Steelcraft | Schlage Commercial » Steelcraft
What is the difference between galvanized and galvannealed steel?
Galvannealed and galvanized steel are zinc coated at the steel mills and are designed for rust and corrosion resistance. Both steels are passed through a hot dip coating process for rust prevention. G...
Schlage Commercial » Doors and Frames » Doors » A14 Series » Steelcraft | Schlage Commercial » Doors and Frames » Doors » B Series » Steelcraft | Schlage Commercial » Doors and Frames » Doors » CE Series » Steelcraft | Schlage Commercial » Doors and Frames » Doors » H Series » Steelcraft | Schlage Commercial » Doors and Frames » Doors » L-Series » Steelcraft | Schlage Commercial » Doors and Frames » Doors » Paladin PW Series » Steelcraft | Schlage Commercial » Doors and Frames » Doors » T Series » Steelcraft | Schlage Commercial » Doors and Frames » Frames » DW & K Series » Steelcraft | Schlage Commercial » Doors and Frames » Frames » F & FN Series » Steelcraft | Schlage Commercial » Doors and Frames » Frames » FE & DE Series » Steelcraft | Schlage Commercial » Doors and Frames » Frames » Frame Elevations » Steelcraft | Schlage Commercial » Doors and Frames » Frames » MU Series » Steelcraft
Can DE-Series frames be prepared for pocket pivot hinges?
Pocket pivot hinges are mainly used in cross corridor applications where clear opening width is a factor. For frames, pocket pivot hinges are a special hinge options which must be specif...
Schlage Commercial » Doors and Frames » Frames » F & FN Series » Steelcraft | Schlage Commercial » Doors and Frames » Frames » FE & DE Series » Steelcraft | Schlage Commercial » Steelcraft
What is the most common practice for running electric power from a frame to the door and hardware?
Electrical hinges or a power transfer units are the most commonly used practices to run electric power to locks and/or strikes. Electric Hinges: Most electric hinges will fit into a ...
Schlage Commercial » Doors and Frames » Doors » A14 Series » Steelcraft | Schlage Commercial » Doors and Frames » Doors » B Series » Steelcraft | Schlage Commercial » Doors and Frames » Doors » CE Series » Steelcraft | Schlage Commercial » Doors and Frames » Doors » H Series » Steelcraft | Schlage Commercial » Doors and Frames » Doors » L-Series » Steelcraft | Schlage Commercial » Doors and Frames » Doors » T Series » Steelcraft | Schlage Commercial » Doors and Frames » Frames » DW & K Series » Steelcraft | Schlage Commercial » Doors and Frames » Frames » F & FN Series » Steelcraft | Schlage Commercial » Doors and Frames » Frames » FE & DE Series » Steelcraft | Schlage Commercial » Doors and Frames » Frames » MU Series » Steelcraft | Schlage Commercial » Steelcraft
Does Steelcraft offer a KD (knocked down) assembly for sidelight frames?
Side Light and Side Panel frames - Side Light and Side Panel frames are not KD (Knock Down), they must be assembled and welded. All side lite and side panel frames must be assembled and welded p...
Schlage Commercial » Doors and Frames » Frames » F & FN Series » Steelcraft | Schlage Commercial » Doors and Frames » Frames » Frame Elevations » Steelcraft | Schlage Commercial » Doors and Frames » Frames » MU Series » Steelcraft | Schlage Commercial » Steelcraft
Can DW/K frame series be used in high traffic areas?
DW/K-Series frames (Drywall Slip-On) are not recommended for installation in high traffic areas. DW/K-Series frames are installed in interior stud walls after the wall board is installed and usu...
Schlage Commercial » Doors and Frames » Frames » DW & K Series » Steelcraft | Schlage Commercial » Doors and Frames » Frames » F & FN Series » Steelcraft | Schlage Commercial » Doors and Frames » Frames » MU Series » Steelcraft
What is the rough opening in walls for frame installations?
 For DW, K three sided frames and four sided borrowed light frames: Three sided frame = door opening width (order size) plus 1 1/2" minimum to 2" maximum and the door opening height...
Schlage Commercial » Doors and Frames » Frames » DW & K Series » Steelcraft | Schlage Commercial » Doors and Frames » Frames » F & FN Series » Steelcraft | Schlage Commercial » Doors and Frames » Frames » FE & DE Series » Steelcraft | Schlage Commercial » Doors and Frames » Frames » MU Series » Steelcraft | Schlage Commercial » Steelcraft