How do I set the hold open on my 4040 closer?
The hold open position on a "REG" or "EDA"  hold open arm is set with the door to a few degrees shy of the desired hold open point. To properly set, open the door 5° less then the desired hold open...
Schlage Commercial » Door Controls » Concealed » 3030 Series » LCN | Schlage Commercial » Door Controls » Concealed » 5030 Series » LCN | Schlage Commercial » Door Controls » Surface Mounted » 1070 Series » LCN | Schlage Commercial » Door Controls » Surface Mounted » 1460 Series » LCN | Schlage Commercial » Door Controls » Surface Mounted » 4010 Series » LCN | Schlage Commercial » Door Controls » Surface Mounted » 4020 Series » LCN | Schlage Commercial » Door Controls » Surface Mounted » 4030 Series » LCN | Schlage Commercial » Door Controls » Surface Mounted » 4040 Series » LCN | Schlage Commercial » Door Controls » Surface Mounted » 4110 Series » LCN | Schlage Commercial » Door Controls » Surface Mounted » 4130 Series » LCN | Schlage Commercial » Door Controls » Surface Mounted » SC60 Series » Falcon | Schlage Commercial » Door Controls » Surface Mounted » SC70 Series » Falcon | Schlage Commercial » Door Controls » Surface Mounted » SC80 Series » Falcon | Schlage Commercial » Door Controls » Surface Mounted » SC90 Series » Falcon | Schlage Commercial » LCN
What is the Website for Dor-O-Matic mechanical door closers?
Dor-O-Matic mechanical closers have been re-branded as Falcon and can be found at the Falcon website....
Schlage Commercial » Automatic Operators » Electromechanical » 8200 Series » Falcon | Schlage Commercial » Door Controls » Surface Mounted » SC60 Series » Falcon | Schlage Commercial » Door Controls » Surface Mounted » SC70 Series » Falcon | Schlage Commercial » Door Controls » Surface Mounted » SC80 Series » Falcon | Schlage Commercial » Door Controls » Surface Mounted » SC90 Series » Falcon
Are the Falcon SC Series door closers fire rated?
Yes, the Falcon SC Series closers have a UL listing....
Schlage Commercial » Door Controls » Surface Mounted » SC60 Series » Falcon | Schlage Commercial » Door Controls » Surface Mounted » SC70 Series » Falcon | Schlage Commercial » Door Controls » Surface Mounted » SC80 Series » Falcon | Schlage Commercial » Door Controls » Surface Mounted » SC90 Series » Falcon
What is a surface mounted door closer?
Surface Mounted door closers are the most durable and common type of door closer. Mounted to the surface of the door or frame Can be configured (through installation or arm type) to meet a wi...
Schlage Commercial » Door Controls » High Security » 4210 Series » LCN | Schlage Commercial » Door Controls » High Security » 4510 Series » LCN | Schlage Commercial » Door Controls » Surface Mounted » 1460 Series » LCN | Schlage Commercial » Door Controls » Surface Mounted » 4010 Series » LCN | Schlage Commercial » Door Controls » Surface Mounted » 4020 Series » LCN | Schlage Commercial » Door Controls » Surface Mounted » 4030 Series » LCN | Schlage Commercial » Door Controls » Surface Mounted » 4040 Series » LCN | Schlage Commercial » Door Controls » Surface Mounted » 4110 Series » LCN | Schlage Commercial » Door Controls » Surface Mounted » SC60 Series » Falcon | Schlage Commercial » Door Controls » Surface Mounted » SC70 Series » Falcon | Schlage Commercial » Door Controls » Surface Mounted » SC80 Series » Falcon | Schlage Commercial » Door Controls » Surface Mounted » SC90 Series » Falcon | Schlage Commercial » Door Controls » Surface Mounted » 4000 Series » LCN | Schlage Commercial » LCN
What is the narrowest width door the Falcon SC81A closer can be mounted on in a Pull side installation?
A 16” wide door leaf, when installed to the 180 degree standard template....
Schlage Commercial » Door Controls » Surface Mounted » SC80 Series | Schlage Commercial » Door Controls » Surface Mounted » SC80 Series » Falcon
What is the smallest width door the SC81A can mount Parallel Arm on?
23” with Rw/PA or Hw/PA arm when templated at 180 degree of swing. 22” with HDPA arm when templated at 180 degree of swing. 23” with DS, DS/HO, SS, or SS/HO arm when templated a...
Schlage Commercial » Door Controls » Surface Mounted » SC80 Series » Falcon
What is the narrowest door the SC81A can mount Top Jamb on?
A 20” wide door, when templated for 180 degree of swing....
Schlage Commercial » Door Controls » Surface Mounted » SC80 Series | Schlage Commercial » Door Controls » Surface Mounted » SC80 Series » Falcon
Is the Falcon SC series Closers hold open wrench sold separately?
The Falcon Hold Open wrench is not available for individual purchase.  The LCN 1250/1450 Hold Open wrench would work as a replacement.  This can be ordered thru LCN with part number...
Schlage Commercial » Door Controls » Surface Mounted » SC60 Series | Schlage Commercial » Door Controls » Surface Mounted » SC60 Series » Falcon | Schlage Commercial » Door Controls » Surface Mounted » SC70 Series | Schlage Commercial » Door Controls » Surface Mounted » SC70 Series » Falcon | Schlage Commercial » Door Controls » Surface Mounted » SC80 Series | Schlage Commercial » Door Controls » Surface Mounted » SC80 Series » Falcon | Schlage Commercial » Door Controls » Surface Mounted » SC90 Series | Schlage Commercial » Door Controls » Surface Mounted » SC90 Series » Falcon
Is the Falcon Blade Stop Spacer the same as the LCN Blade Stop Spacer?
Yes.  The -61 Blade Stop Spacer, The Physical part itself, is the same for both Falcon and LCN brand closers and interchangeable between both Brands.  It is the templating of the closer it...
Schlage Commercial » Door Controls » Surface Mounted » 1260 Series | Schlage Commercial » Door Controls » Surface Mounted » 1260 Series » LCN | Schlage Commercial » Door Controls » Surface Mounted » 4030 Series | Schlage Commercial » Door Controls » Surface Mounted » 4040 Series » LCN | Schlage Commercial » Door Controls » Surface Mounted » 4040XP Series | Schlage Commercial » Door Controls » Surface Mounted » 4110 Series | Schlage Commercial » Door Controls » Surface Mounted » SC60 Series | Schlage Commercial » Door Controls » Surface Mounted » SC60 Series » Falcon | Schlage Commercial » Door Controls » Surface Mounted » SC70 Series | Schlage Commercial » Door Controls » Surface Mounted » SC70 Series » Falcon | Schlage Commercial » Door Controls » Surface Mounted » SC80 Series | Schlage Commercial » Door Controls » Surface Mounted » SC80 Series » Falcon | Schlage Commercial » Door Controls » Surface Mounted » 4000 Series | Schlage Commercial » LCN | Schlage Commercial » Door Controls » Surface Mounted » 1250 Series | Schlage Commercial » Door Controls » Surface Mounted » 1450T Series | Schlage Commercial » Door Controls » Surface Mounted » 4050 Series
What door hardware is FEMA approved for Steelcraft Paladin Tornado doors and frames?
For a current list of approved door hardware, please refer to Tornado section of the Steelcraft Tech Data Manual, which can be found here.  Within this section you will find the following:...