What is the LCN fluid - "Liquid X" - temperature range?
The LCN closer fluid "Liquid X" will perform without variation between:
-30° F to +120° F - for manual closers.
+35° F to +120° F - for electrical closers and ...
Schlage Commercial » Automatic Operators » Electrohydraulic » 4630 Series » LCN | Schlage Commercial » Automatic Operators » Pneumatics » 2610 Series » LCN | Schlage Commercial » Automatic Operators » Pneumatics » 4810 Series » LCN | Schlage Commercial » Door Controls » Overhead Concealed » 2010 Series » LCN | Schlage Commercial » Door Controls » Overhead Concealed » 2030 Series » LCN | Schlage Commercial » Door Controls » Concealed » 3030 Series » LCN | Schlage Commercial » Door Controls » Concealed » 3130 Series » LCN | Schlage Commercial » Door Controls » Concealed » 5030 Series » LCN | Schlage Commercial » Door Controls » Concealed » 6030 Series » LCN | Schlage Commercial » Door Controls » Fire Life Safety » Fire/Life Safety Series » LCN | Schlage Commercial » Door Controls » High Security » 2210 Series » LCN | Schlage Commercial » Door Controls » High Security » 4210 Series » LCN | Schlage Commercial » Door Controls » High Security » 4510 Series » LCN | Schlage Commercial » Door Controls » Surface Mounted » 1460 Series » LCN | Schlage Commercial » Door Controls » Surface Mounted » 4010 Series » LCN | Schlage Commercial » Door Controls » Surface Mounted » 4020 Series » LCN | Schlage Commercial » Door Controls » Surface Mounted » 4030 Series » LCN | Schlage Commercial » Door Controls » Surface Mounted » 4040 Series » LCN | Schlage Commercial » Door Controls » Surface Mounted » 4110 Series » LCN | Schlage Commercial » Door Controls » Surface Mounted » 4000 Series » LCN | Schlage Commercial » LCN
What drop plate is used with a 4040 Rw/PA?
The 4040 Rw/PA can be mounted 3 different ways.
The 4040-18 drop plate is used for the regular pull side mount.
The 4040-18TJ drop plate is used for the top jamb push side mount.
The 4040-18PA...
Schlage Commercial » Door Controls » Surface Mounted » 4040 Series » LCN
4040XP door closer door too hard to open.
The 4040XP closer can be hard to open if the Spring Adjustment is set to strong. Try reducing the spring power by turning it down on closer (counter-clockwise)....
Schlage Commercial » Door Controls » Surface Mounted » 4040 Series » LCN
Is the Cush Shoe Support (-30) the same for all of LCN closers?
For LCN Cast Iron Closers, the 4050A, and Falcon SC closers it is (1 3/4") wide, (1 1/2") tall and (1 1/2") deep
For 1250 and 1450 LCN Alum body Closers it is (2") wide, (1 1/2") tall and (1 1/2") d...
Schlage Commercial » Automatic Operators » Pneumatics » 4840 Series » LCN | Schlage Commercial » Door Controls » Automatic Operator | Schlage Commercial » Door Controls » High Security » 4210 Series » LCN | Schlage Commercial » Door Controls » Surface Mounted » 1260 Series | Schlage Commercial » Door Controls » Surface Mounted » 1460 Series | Schlage Commercial » Door Controls » Surface Mounted » 4030 Series | Schlage Commercial » Door Controls » Surface Mounted » 4030 Series » LCN | Schlage Commercial » Door Controls » Surface Mounted » 4040 Series » LCN | Schlage Commercial » Door Controls » Surface Mounted » 4040XP Series | Schlage Commercial » Door Controls » Surface Mounted » 4110 Series | Schlage Commercial » Door Controls » Surface Mounted » 4110 Series » LCN | Schlage Commercial » Door Controls » Surface Mounted » SC60 Series | Schlage Commercial » Door Controls » Surface Mounted » SC70 Series | Schlage Commercial » Door Controls » Surface Mounted » SC80 Series | Schlage Commercial » Door Controls » Surface Mounted » 1250 Series | Schlage Commercial » Door Controls » Surface Mounted » 1450 Series | Schlage Commercial » Door Controls » Surface Mounted » 4050 Series
Can a 4040 open to 180°?
The 4040/4040XP closer mountings have the following maximum opening degree templating:
The 4040/4040XP PA "Regular Arm" mount will allow for 180° max. opening.
The 4040/4040XP...
Schlage Commercial » Door Controls » Surface Mounted » 4040 Series » LCN
What is the part # for the 4040 regular arm?
The 4040 regular and hold open arms are different. You would have to get a different arm to convert from regular arm to a hold open function.
4040-3077 for a regular arm.
4040-3077L for a long...
Schlage Commercial » Door Controls » Surface Mounted » 4040 Series » LCN
Which closers are available with the TEL option?
The TEL option is only available on the 4010, 4020, and the 4110 series closers.
The 4041/4040XP is not available with TEL (telephone closer). ...
Schlage Commercial » Door Controls » Surface Mounted » 4010 Series » LCN | Schlage Commercial » Door Controls » Surface Mounted » 4020 Series » LCN | Schlage Commercial » Door Controls » Surface Mounted » 4040 Series » LCN | Schlage Commercial » Door Controls » Surface Mounted » 4110 Series » LCN