Which closer is the heaviest duty?
The 4010, 4020, 4110, and 4040/4040XP are heavy duty closers....
Schlage Commercial » Door Controls » Surface Mounted » 4010 Series » LCN | Schlage Commercial » Door Controls » Surface Mounted » 4020 Series » LCN | Schlage Commercial » Door Controls » Surface Mounted » 4040 Series » LCN | Schlage Commercial » Door Controls » Surface Mounted » 4110 Series » LCN
What is the normal closing time that a door closer should be set to?
LCN recommends a normal closing time from 90° door open position is 5 to 7 seconds, evenly divided between main speed and latch speed....
Schlage Commercial » Automatic Operators » Electrohydraulic » 4630 Series » LCN | Schlage Commercial » Automatic Operators » Pneumatics » 2610 Series » LCN | Schlage Commercial » Automatic Operators » Pneumatics » 4810 Series » LCN | Schlage Commercial » Door Controls » Overhead Concealed » 2010 Series » LCN | Schlage Commercial » Door Controls » Overhead Concealed » 2030 Series » LCN | Schlage Commercial » Door Controls » Concealed » 3030 Series » LCN | Schlage Commercial » Door Controls » Concealed » 3130 Series » LCN | Schlage Commercial » Door Controls » Concealed » 5030 Series » LCN | Schlage Commercial » Door Controls » Concealed » 6030 Series » LCN | Schlage Commercial » Door Controls » Fire Life Safety » Fire/Life Safety Series » LCN | Schlage Commercial » Door Controls » High Security » 2210 Series » LCN | Schlage Commercial » Door Controls » High Security » 4210 Series » LCN | Schlage Commercial » Door Controls » High Security » 4510 Series » LCN | Schlage Commercial » Door Controls » Surface Mounted » 1460 Series » LCN | Schlage Commercial » Door Controls » Surface Mounted » 4010 Series » LCN | Schlage Commercial » Door Controls » Surface Mounted » 4020 Series » LCN | Schlage Commercial » Door Controls » Surface Mounted » 4030 Series » LCN | Schlage Commercial » Door Controls » Surface Mounted » 4040 Series » LCN | Schlage Commercial » Door Controls » Surface Mounted » 4110 Series » LCN | Schlage Commercial » Door Controls » Surface Mounted » 4000 Series » LCN | Schlage Commercial » LCN
What does AVB mean in a closer and which closers are available with this option?
AVB stands for Advanced Variable Backcheck. It is a cylinder option when ordering a 4111 closer (without an ST) that allows backcheck to start at about 45 degrees instead of the normal 75 degrees.The ...
Schlage Commercial » Door Controls » Surface Mounted » 4010 Series » LCN | Schlage Commercial » Door Controls » Surface Mounted » 4020 Series » LCN | Schlage Commercial » Door Controls » Surface Mounted » 4110 Series » LCN
Does the WMS screwpack also have SRT screws?
The WMS (Wood Machine Screw) and the SRT (Self Reaming Tapping) are separate screw packs....
Schlage Commercial » Automatic Operators » Electrohydraulic » 4630 Series » LCN | Schlage Commercial » Automatic Operators » Pneumatics » 2610 Series » LCN | Schlage Commercial » Automatic Operators » Pneumatics » 4810 Series » LCN | Schlage Commercial » Door Controls » Overhead Concealed » 2010 Series » LCN | Schlage Commercial » Door Controls » Overhead Concealed » 2030 Series » LCN | Schlage Commercial » Door Controls » Concealed » 3030 Series » LCN | Schlage Commercial » Door Controls » Concealed » 3130 Series » LCN | Schlage Commercial » Door Controls » Concealed » 5030 Series » LCN | Schlage Commercial » Door Controls » Concealed » 6030 Series » LCN | Schlage Commercial » Door Controls » Fire Life Safety » Fire/Life Safety Series » LCN | Schlage Commercial » Door Controls » High Security » 2210 Series » LCN | Schlage Commercial » Door Controls » High Security » 4210 Series » LCN | Schlage Commercial » Door Controls » High Security » 4510 Series » LCN | Schlage Commercial » Door Controls » Surface Mounted » 1460 Series » LCN | Schlage Commercial » Door Controls » Surface Mounted » 4010 Series » LCN | Schlage Commercial » Door Controls » Surface Mounted » 4020 Series » LCN | Schlage Commercial » Door Controls » Surface Mounted » 4030 Series » LCN | Schlage Commercial » Door Controls » Surface Mounted » 4040 Series » LCN | Schlage Commercial » Door Controls » Surface Mounted » 4110 Series » LCN | Schlage Commercial » Door Controls » Surface Mounted » 4000 Series » LCN | Schlage Commercial » LCN
What LCN closer has the strongest closing force?
The size 6 handed closers will have the most (strongest) closing force. The 4016 (pull side), the 4026 (top jamb push side) or the 4116  (push side parallel arm)  have the highest closing force....
Schlage Commercial » Door Controls » Surface Mounted » 4010 Series » LCN | Schlage Commercial » Door Controls » Surface Mounted » 4020 Series » LCN | Schlage Commercial » Door Controls » Surface Mounted » 4110 Series » LCN
How do I set the hold open on my 4040 closer?
The hold open position on a "REG" or "EDA"  hold open arm is set with the door to a few degrees shy of the desired hold open point. To properly set, open the door 5° less then the desired hold open...
Schlage Commercial » Door Controls » Concealed » 3030 Series » LCN | Schlage Commercial » Door Controls » Concealed » 5030 Series » LCN | Schlage Commercial » Door Controls » Surface Mounted » 1070 Series » LCN | Schlage Commercial » Door Controls » Surface Mounted » 1460 Series » LCN | Schlage Commercial » Door Controls » Surface Mounted » 4010 Series » LCN | Schlage Commercial » Door Controls » Surface Mounted » 4020 Series » LCN | Schlage Commercial » Door Controls » Surface Mounted » 4030 Series » LCN | Schlage Commercial » Door Controls » Surface Mounted » 4040 Series » LCN | Schlage Commercial » Door Controls » Surface Mounted » 4110 Series » LCN | Schlage Commercial » Door Controls » Surface Mounted » 4130 Series » LCN | Schlage Commercial » Door Controls » Surface Mounted » SC60 Series » Falcon | Schlage Commercial » Door Controls » Surface Mounted » SC70 Series » Falcon | Schlage Commercial » Door Controls » Surface Mounted » SC80 Series » Falcon | Schlage Commercial » Door Controls » Surface Mounted » SC90 Series » Falcon | Schlage Commercial » LCN
What special template (ST) is used with a 4020 closer and a deep reveal?
The "Regular Arm" allows for 180 degree with reveals up to 2-9/16” or 140 degree with reveals up to 4”The “Long Arm” allows for 140 degree with reveals from over 4” up to 8”ST-2458 will ac...
Schlage Commercial » Door Controls » Surface Mounted » 4020 Series » LCN
What can be done for a door that will not close against wind pressure?
To correctly answer this question, we need to know how much more force is required to get the door closed. They could try turning the Rod & Shoe over (short side of shoe towards the hinge), or they m...
Schlage Commercial » Door Controls » Surface Mounted » 4010 Series » LCN | Schlage Commercial » Door Controls » Surface Mounted » 4020 Series » LCN | Schlage Commercial » Door Controls » Surface Mounted » 4040 Series » LCN | Schlage Commercial » Door Controls » Surface Mounted » 4110 Series » LCN
What special template (ST) is used to get a 4040 closer without a spring, for checking only?
ST-2687 is for a closer that is assembled without a spring.   For any large body closer (4010, 4020, 4110, and 4040 series closers), not the 1460/1460T, 1260, 4030/4030T, 2030, 5030, 6030 30...
Schlage Commercial » Door Controls » Overhead Concealed » 2010 Series » LCN | Schlage Commercial » Door Controls » Overhead Concealed » 2030 Series » LCN | Schlage Commercial » Door Controls » Concealed » 5030 Series » LCN | Schlage Commercial » Door Controls » High Security » 2210 Series » LCN | Schlage Commercial » Door Controls » High Security » 4210 Series » LCN | Schlage Commercial » Door Controls » High Security » 4510 Series » LCN | Schlage Commercial » Door Controls » Surface Mounted » 4010 Series » LCN | Schlage Commercial » Door Controls » Surface Mounted » 4020 Series » LCN | Schlage Commercial » Door Controls » Surface Mounted » 4040 Series » LCN | Schlage Commercial » Door Controls » Surface Mounted » 4110 Series » LCN | Schlage Commercial » LCN
Can a 4010 be used on the push side of the door like a 4020?
The 4010 and 4020 use the same door closer cylinder, the rod and shoe and covers are different. To use a 4010 cylinder as a 4020, you will need a 4020-79 rod and shoe and a 4020-72 cover. To us...