How do you install the arms on a 9100 Series Benchmark operator?
The installation of the arms with the Benchmark and Falcon Swing Door Operator is similar to the Sr. Swing Series . The arms are installed with the main activation input shorted, the gearbox at the fu...
Schlage Commercial » Automatic Operators » Electromechanical » 8200 Series » Falcon | Schlage Commercial » Automatic Operators » Electromechanical » Benchmark » LCN
Can a Cam Lift hinge be used with LCN closers?
Cam Lift hinges can only be used with LCN door closers that have a "Regular" or "Reg hold Open" style arm. Manual Closers:Maximum lift dimension is 3/4".Can not be use (H)EDA, CUSH, or Trac...
Schlage Commercial » Automatic Operators » Electrohydraulic » 4640 Series » LCN | Schlage Commercial » Automatic Operators » Electromechanical » 8200 Series » Falcon | Schlage Commercial » Automatic Operators » Electromechanical » Benchmark » LCN | Schlage Commercial » Automatic Operators » Electromechanical » Senior Swing » LCN | Schlage Commercial » Automatic Operators » Pneumatics » 4820 Series » LCN | Schlage Commercial » Door Controls » Fire Life Safety » Fire/Life Safety Series » LCN | Schlage Commercial » Door Controls » High Security » 4510 Series » LCN | Schlage Commercial » Door Controls » Surface Mounted » 1070 Series » LCN | Schlage Commercial » Door Controls » Surface Mounted » 1460 Series » LCN | Schlage Commercial » Door Controls » Surface Mounted » 4010 Series » LCN | Schlage Commercial » Door Controls » Surface Mounted » 4020 Series » LCN | Schlage Commercial » Door Controls » Surface Mounted » 4030 Series » LCN | Schlage Commercial » Door Controls » Surface Mounted » 4040 Series » LCN | Schlage Commercial » LCN
What does the term "Reveal" mean?
Reveal is the distance or measurement from the face of the door (in closed position) out to the face of the frame or trim.
See here for image of Push side reveal.
See here for ima...
Schlage Commercial » Automatic Operators » Electromechanical » 8200 Series » Falcon | Schlage Commercial » Door Controls » Surface Mounted » 4040 Series » LCN | Schlage Commercial » Door Controls » Surface Mounted » SC60 Series » Falcon | Schlage Commercial » Door Controls » Surface Mounted » SC70 Series » Falcon | Schlage Commercial » Door Controls » Surface Mounted » SC80 Series » Falcon | Schlage Commercial » Door Controls » Surface Mounted » SC90 Series » Falcon | Schlage Commercial » LCN
How deep of a reveal will an 8200 Falcon Operator accommodate?
The maximum reveal for an 8200 Falcon Operator is:
8230 (pull side) -- 1/8"
8240 (push side) -- 6"
The Benchmark long rod and shoe (9140-79LR) can be use with the Falcon 8242 for reveal from 6...
Schlage Commercial » Automatic Operators » Electromechanical » 8200 Series » Falcon
Can the 8200 Series operator power a electric strike?
The 8200 Series operator CANNOT power a strike, maglock, or EL device. A separate power supply is ALWAYS required. There is an onboard relay to control a strike, maglock, or EL device....
Schlage Commercial » Automatic Operators » Electromechanical » 8200 Series » Falcon
Why would a Falcon 8200 Series operator be blowing the fuse?
If the Main AC fuse is blowing, the control box is defective and needs to be replaced. The "Main Fuse" is a (5x20MM) 1 Amp Slow Blow fuse.
If the 12VAC fuse is blowing, verify they are not trying t...
Schlage Commercial » Automatic Operators » Electromechanical » 8200 Series » Falcon
How do I fix a Benchmark 9100 that the belt keeps sliding down on motor gearbox?
The Benchmark and Falcon operator gearbox assemblies are not repairable. The gearbox belt and/or pulley cannot be replaced in the field, the gearbox would need to be replaced as a complete assembly.
...
Schlage Commercial » Automatic Operators » Electromechanical » 8200 Series » Falcon | Schlage Commercial » Automatic Operators » Electromechanical » Benchmark » LCN
What power supply do I need for my 2 QELA devices with LCN auto operator?
Use the PS902-2RS power supply with LCN auto operator on single door, PS904-2RS power supply on double door and PS904/906-2RS-2RS for 2 pair of QELA is required for basic operation with actu...
Schlage Commercial » Automatic Operators » Electrohydraulic » 4630 Series » LCN | Schlage Commercial » Automatic Operators » Electromechanical » 8200 Series » Falcon | Schlage Commercial » Automatic Operators » Electromechanical » Benchmark » LCN | Schlage Commercial » Automatic Operators » Electromechanical » Senior Swing » LCN | Schlage Commercial » Door Controls » Automatic Operator » 7900 Series » LCN | Schlage Commercial » Door Controls » Automatic Operator » 7980 Series » LCN | Schlage Commercial » Power Supplies » Standard » PS900 Series » Von Duprin