Why would a 8310-806K be used in conjunction with a 4600 that has a on/off hold open switch?
For wiring diagram see here. ...
Schlage Commercial » Automatic Operators » Electrohydraulic » 4630 Series » LCN | Schlage Commercial » Automatic Operators » Electrohydraulic » 4640 Series » LCN | Schlage Commercial » Door Controls » Automatic Operator » 8310 Series » LCN
What is a 7910-967?
The 7910-967 is a part number for a discontinued RF actuator. It was replaced by the 8310-3856WS RF actuator. The new 8310-3856WS requires the use of an 8310-865 RF receiver. When replacing the old...
Schlage Commercial » Door Controls » Automatic Operator » 8310 Series » LCN
What components are needed to convert a hard wired actuator button to a wireless actuator button?
To convert an RF actuator button to a hard wired actuator button, simply remove the RF transmitter an connect the hard wiring to the "Common" and "Normally Open" terminals on the the switch....
Schlage Commercial » Door Controls » Automatic Operator » 8310 Series » LCN
Will a new RF "programmable" transmitter work with an older RF receiver that has "dip switches"?
The newer "programmable" RF transmitters/receivers will not work with the older "dip switch" transmitters/receivers. The frequency and coding are different....
Schlage Commercial » Door Controls » Automatic Operator » 8310 Series » LCN
What is the average battery life on wireless actuators?
On average, the battery life on the wireless actuators will be 9 months to 1 year for most installations. Extreme (cold) conditions may reduce battery life....
Schlage Commercial » Door Controls » Automatic Operator » 8310 Series » LCN
Does LCN still sell the 761469 retrofit cable, part # 8310-887?
LCN Sr Swing retrofit cable and kit (8310-887 and 8310-3134) were both obsoleted early 2018.  The retrofit cable -887 was for activation and was included in the retrofit kit -3134.  They wer...
Schlage Commercial » Automatic Operators | Schlage Commercial » Automatic Operators » Actuators | Schlage Commercial » Automatic Operators » Actuators » Actuators and Accessories | Schlage Commercial » Automatic Operators » Actuators » Actuators and Accessories » LCN | Schlage Commercial » Automatic Operators » Electromechanical | Schlage Commercial » Automatic Operators » Electromechanical » Senior Swing | Schlage Commercial » Automatic Operators » Electromechanical » Senior Swing » LCN | Schlage Commercial » Door Controls | Schlage Commercial » Door Controls » Automatic Operator | Schlage Commercial » Door Controls » Automatic Operator » 8310 Series | Schlage Commercial » Door Controls » Automatic Operator » 8310 Series » LCN | Schlage Commercial » LCN | Schlage Commercial
Can a magnet, or sentronic device, be released and close the door from a button at a desk?
If a door is being held open by the LCN SEM 7800/1900 magnet or any ME/SE Series Sentronic LCN closer, you can remotely release that door to close by ordering the following parts and wiring ...
Schlage Commercial » Door Controls » Automatic Operator » 8310 Series » LCN | Schlage Commercial » Door Controls » Fire Life Safety » Multi Point Hold Open Closer | Schlage Commercial » Door Controls » Fire Life Safety » Single Point Hold Open Closer | Schlage Commercial » Door Controls » Fire Life Safety » Fire/Life Safety Series » LCN | Schlage Commercial » Door Controls » Fire Life Safety » SEM Series » LCN
Can a 8310-818 be used outside?
Exterior mounting of the 8310-818 series actuators is not recommended. The 8310-818 series actuators are designed to be jamb mounted on the frame. With that installation, the person will have to sta...
Schlage Commercial » Door Controls » Automatic Operator » 8310 Series » LCN
How do you wire the 8310-865 receiver to a 4600 Series operator?
The 4630/4640 operator can accept any ( normally open / dry contact) actuator - hardwired or wireless.  LCN Wireless actuators require the use of the 8310-865 RF receiver.The 8310-865 RF Rec...
Schlage Commercial » Automatic Operators » Electrohydraulic » 4630 Series | Schlage Commercial » Automatic Operators » Electrohydraulic » 4630 Series » LCN | Schlage Commercial » Automatic Operators » Electrohydraulic » 4640 Series | Schlage Commercial » Automatic Operators » Electrohydraulic » 4640 Series » LCN | Schlage Commercial » Door Controls » Automatic Operator » 8310 Series » LCN
What is the new number for a 7910-931 receiver?
The obsolete 7910-931 receiver has been replaced by the 8310-865 receiver.Replacing the receiver requires you to also replace the obsolete 7910-444 transmitter module with the 8310-844 transmitter....