How is the 8310-877 wired to the 4600 (4630 4640) operator?
The 8310-877 comes with a 6 wire cable. You have to cut the connectors off both ends and hardwire it to the 4600 operator as follows: The 6 wire cable connections to the 7 pin connector in the 8310-87...
Schlage Commercial » Automatic Operators » Electrohydraulic » 4630 Series » LCN | Schlage Commercial » Automatic Operators » Electrohydraulic » 4640 Series » LCN
How do you get a 4600 Series operator out of "Fire Alarm" mode?
The "Fire Alarm" indication occurs when there is no connection across terminals 13 & 14.
Check to verify that the "Fire Alarm" shunt (R1 jumper) on the I/O board has not been cut.
Install jumper ...
Schlage Commercial » Automatic Operators » Electrohydraulic » 4630 Series » LCN
Can I make a wireless activated 4640 operator work as alternate action?
The 8310-865 RF receiver contacts (N.O. and COM) would connect to terminals 15 & 17 (the alternate action input) on the 4600 operator.
The first activation would open the door, the seco...
Schlage Commercial » Automatic Operators » Electrohydraulic » 4630 Series » LCN | Schlage Commercial » Automatic Operators » Electrohydraulic » 4640 Series » LCN | Schlage Commercial » Door Controls » Automatic Operator » 8310 Series » LCN
Can a wireless actuator be converted to hardwired?
Yes. Remove the receiver from the operator. Remove the transmitter from the actuator button. Attach 1 wire to the NO (normally open) contact on the actuator switch, and another wire to the COM (co...
Schlage Commercial » Automatic Operators » Electrohydraulic » 4630 Series » LCN | Schlage Commercial » Automatic Operators » Electromechanical » Benchmark » LCN | Schlage Commercial » Automatic Operators » Electromechanical » Senior Swing » LCN | Schlage Commercial » Automatic Operators » Pneumatics » 2610 Series » LCN | Schlage Commercial » Automatic Operators » Pneumatics » 4810 Series » LCN | Schlage Commercial » Door Controls » Automatic Operator » 7900 Series » LCN | Schlage Commercial » Door Controls » Automatic Operator » 7980 Series » LCN | Schlage Commercial » Door Controls » Automatic Operator » 8310 Series » LCN
Does LCN offer battery back up for power operators?
In early 2022 LCN launched a battery back up for power operators. Part number is SOLA. The battery back up will allow up to two single operators to cycle at least 100 times after power loss....
Schlage Commercial » Automatic Operators » Electrohydraulic | Schlage Commercial » Automatic Operators » Electrohydraulic » 4630 Series | Schlage Commercial » Automatic Operators » Electrohydraulic » 4630 Series » LCN | Schlage Commercial » Automatic Operators » Electrohydraulic » 4640 Series » LCN | Schlage Commercial » Automatic Operators » Electromechanical » 8200 Series » Falcon | Schlage Commercial » Automatic Operators » Electromechanical » Benchmark | Schlage Commercial » Automatic Operators » Electromechanical » Benchmark » LCN | Schlage Commercial » Automatic Operators » Electromechanical » Senior Swing | Schlage Commercial » Automatic Operators » Electromechanical » Senior Swing » LCN | Schlage Commercial » Door Controls » Automatic Operator » 7900 Series » LCN | Schlage Commercial » Door Controls » Automatic Operator » 7980 Series » LCN | Schlage Commercial » LCN
Is the motor clutch assembly the same on the 4640 and 4630?
The Motor Clutch Assembly is the same for both the 4630 and the 4640 operators. Part # is Series # - 3454.
The 4630/4640 motor clutch comes as a complete assembly only, no individual...
Schlage Commercial » Automatic Operators » Electrohydraulic | Schlage Commercial » Automatic Operators » Electrohydraulic » 4630 Series | Schlage Commercial » Automatic Operators » Electrohydraulic » 4630 Series » LCN | Schlage Commercial » Automatic Operators » Electrohydraulic » 4640 Series | Schlage Commercial » Automatic Operators » Electrohydraulic » 4640 Series » LCN
How do you adjust the hold open time on a 4600 (4630/4640) operator?
To adjust the hold open time on a 4600 (4630/4640) operator:Press the "MODE" button on the control box 1 time to get into programming mode. The "YELLOW" mode indicator LED next to "HOLD OPEN TIME" wil...
Schlage Commercial » Automatic Operators » Electrohydraulic » 4630 Series » LCN | Schlage Commercial » Automatic Operators » Electrohydraulic » 4640 Series