Category: LCN

(Results from 41 to 50)
What power supply do I need for my 2 QELA devices with LCN auto operator?
Use the PS902-2RS power supply with LCN auto operator on single door, PS904-2RS power supply on double door and PS904/906-2RS-2RS for 2 pair of QELA is required for basic operation with actu...
Schlage Commercial » Automatic Operators » Electrohydraulic » 4630 Series » LCN | Schlage Commercial » Automatic Operators » Electromechanical » 8200 Series » Falcon | Schlage Commercial » Automatic Operators » Electromechanical » Benchmark » LCN | Schlage Commercial » Automatic Operators » Electromechanical » Senior Swing » LCN | Schlage Commercial » Door Controls » Automatic Operator » 7900 Series » LCN | Schlage Commercial » Door Controls » Automatic Operator » 7980 Series » LCN | Schlage Commercial » Power Supplies » Standard » PS900 Series » Von Duprin
What would cause my door closer to try and open the door instead of closing it?
For a door closer that tries to open the door instead of closing it:The closer body could be mounted backwards on the door - check instructions for proper closer orientation.It could be the wrong hand...
Schlage Commercial » Automatic Operators » Electrohydraulic » 4630 Series » LCN | Schlage Commercial » Automatic Operators » Electromechanical » 8200 Series » Falcon | Schlage Commercial » Automatic Operators » Electromechanical » Benchmark » LCN | Schlage Commercial » Automatic Operators » Electromechanical » Senior Swing » LCN | Schlage Commercial » Automatic Operators » Pneumatics » 2610 Series » LCN | Schlage Commercial » Automatic Operators » Pneumatics » 4810 Series » LCN | Schlage Commercial » Door Controls » Overhead Concealed » 2010 Series » LCN | Schlage Commercial » Door Controls » Overhead Concealed » 2030 Series » LCN | Schlage Commercial » Door Controls » Concealed » 3030 Series » LCN | Schlage Commercial » Door Controls » Concealed » 3130 Series » LCN | Schlage Commercial » Door Controls » Concealed » 5030 Series » LCN | Schlage Commercial » Door Controls » Fire Life Safety » Fire/Life Safety Series » LCN | Schlage Commercial » Door Controls » High Security » 2210 Series » LCN | Schlage Commercial » Door Controls » High Security » 4210 Series » LCN | Schlage Commercial » Door Controls » High Security » 4510 Series » LCN | Schlage Commercial » Door Controls » Surface Mounted » 1460 Series » LCN | Schlage Commercial » Door Controls » Surface Mounted » 4010 Series » LCN | Schlage Commercial » Door Controls » Surface Mounted » 4020 Series » LCN | Schlage Commercial » Door Controls » Surface Mounted » 4030 Series » LCN | Schlage Commercial » Door Controls » Surface Mounted » 4040 Series » LCN | Schlage Commercial » Door Controls » Surface Mounted » 4110 Series » LCN | Schlage Commercial » Door Controls » Surface Mounted » SC60 Series » Falcon | Schlage Commercial » Door Controls » Surface Mounted » SC70 Series » Falcon | Schlage Commercial » Door Controls » Surface Mounted » SC80 Series » Falcon | Schlage Commercial » Door Controls » Surface Mounted » SC90 Series » Falcon | Schlage Commercial » Door Controls » Surface Mounted » 4000 Series » LCN | Schlage Commercial » LCN
What is the normal closing time that a door closer should be set to?
LCN recommends a normal closing time from 90° door open position is 5 to 7 seconds, evenly divided between main speed and latch speed....
Schlage Commercial » Automatic Operators » Electrohydraulic » 4630 Series » LCN | Schlage Commercial » Automatic Operators » Pneumatics » 2610 Series » LCN | Schlage Commercial » Automatic Operators » Pneumatics » 4810 Series » LCN | Schlage Commercial » Door Controls » Overhead Concealed » 2010 Series » LCN | Schlage Commercial » Door Controls » Overhead Concealed » 2030 Series » LCN | Schlage Commercial » Door Controls » Concealed » 3030 Series » LCN | Schlage Commercial » Door Controls » Concealed » 3130 Series » LCN | Schlage Commercial » Door Controls » Concealed » 5030 Series » LCN | Schlage Commercial » Door Controls » Concealed » 6030 Series » LCN | Schlage Commercial » Door Controls » Fire Life Safety » Fire/Life Safety Series » LCN | Schlage Commercial » Door Controls » High Security » 2210 Series » LCN | Schlage Commercial » Door Controls » High Security » 4210 Series » LCN | Schlage Commercial » Door Controls » High Security » 4510 Series » LCN | Schlage Commercial » Door Controls » Surface Mounted » 1460 Series » LCN | Schlage Commercial » Door Controls » Surface Mounted » 4010 Series » LCN | Schlage Commercial » Door Controls » Surface Mounted » 4020 Series » LCN | Schlage Commercial » Door Controls » Surface Mounted » 4030 Series » LCN | Schlage Commercial » Door Controls » Surface Mounted » 4040 Series » LCN | Schlage Commercial » Door Controls » Surface Mounted » 4110 Series » LCN | Schlage Commercial » Door Controls » Surface Mounted » 4000 Series » LCN | Schlage Commercial » LCN
How do you wire the 8310-865 receiver to a 4600 Series operator?
The 4630/4640 operator can accept any ( normally open / dry contact) actuator - hardwired or wireless.  LCN Wireless actuators require the use of the 8310-865 RF receiver.The 8310-865 RF Rec...
Schlage Commercial » Automatic Operators » Electrohydraulic » 4630 Series | Schlage Commercial » Automatic Operators » Electrohydraulic » 4630 Series » LCN | Schlage Commercial » Automatic Operators » Electrohydraulic » 4640 Series | Schlage Commercial » Automatic Operators » Electrohydraulic » 4640 Series » LCN | Schlage Commercial » Door Controls » Automatic Operator » 8310 Series » LCN
What parts are required to update an older 4630 or 4640 operator from the old on/off switch and/or I/O board to the new version?
If you have an old digital 4630 or 4640 operator with an I/O Board assembly that has two terminal strips, one with terminals 1-12, and the other that has 13-24 and you are in need of replacing the O...
Schlage Commercial » Automatic Operators » Electrohydraulic » 4630 Series » LCN | Schlage Commercial » Automatic Operators » Electrohydraulic » 4640 Series » LCN
4600 with EO3, how to troubleshoot and how can you check the clutch and motor on a 4600 operator?
If you get an EO3 on the control box on a 4600 operator.  E03 = Motor / Clutch not plugged in or open coil.  To troubleshoot follow these steps:Verify that the motor is plugged into the cont...
Schlage Commercial » Automatic Operators » Electrohydraulic » 4630 Series » LCN | Schlage Commercial » Automatic Operators » Electrohydraulic » 4640 Series » LCN
Does the WMS screwpack also have SRT screws?
The WMS (Wood Machine Screw) and the SRT (Self Reaming Tapping) are separate screw packs....
Schlage Commercial » Automatic Operators » Electrohydraulic » 4630 Series » LCN | Schlage Commercial » Automatic Operators » Pneumatics » 2610 Series » LCN | Schlage Commercial » Automatic Operators » Pneumatics » 4810 Series » LCN | Schlage Commercial » Door Controls » Overhead Concealed » 2010 Series » LCN | Schlage Commercial » Door Controls » Overhead Concealed » 2030 Series » LCN | Schlage Commercial » Door Controls » Concealed » 3030 Series » LCN | Schlage Commercial » Door Controls » Concealed » 3130 Series » LCN | Schlage Commercial » Door Controls » Concealed » 5030 Series » LCN | Schlage Commercial » Door Controls » Concealed » 6030 Series » LCN | Schlage Commercial » Door Controls » Fire Life Safety » Fire/Life Safety Series » LCN | Schlage Commercial » Door Controls » High Security » 2210 Series » LCN | Schlage Commercial » Door Controls » High Security » 4210 Series » LCN | Schlage Commercial » Door Controls » High Security » 4510 Series » LCN | Schlage Commercial » Door Controls » Surface Mounted » 1460 Series » LCN | Schlage Commercial » Door Controls » Surface Mounted » 4010 Series » LCN | Schlage Commercial » Door Controls » Surface Mounted » 4020 Series » LCN | Schlage Commercial » Door Controls » Surface Mounted » 4030 Series » LCN | Schlage Commercial » Door Controls » Surface Mounted » 4040 Series » LCN | Schlage Commercial » Door Controls » Surface Mounted » 4110 Series » LCN | Schlage Commercial » Door Controls » Surface Mounted » 4000 Series » LCN | Schlage Commercial » LCN
Where does the hold open switch on the 4630 / 4640 wire into on the 1-24 single terminal strip?
The 4600 hold open switch (for the new 1-24 single terminal strip I/O board) wires into terminals 2 and 6 or 4 and 6....
Schlage Commercial » Automatic Operators » Electrohydraulic » 4630 Series » LCN | Schlage Commercial » Automatic Operators » Electrohydraulic » 4640 Series » LCN
Can an auto operator be installed on a Dutch door?
Yes, an automatic operator can be installed on a Dutch door. The operator must be installed on the top leaf of the Dutch door. Only the top half will open unless the top and bottom leaves (secti...
Schlage Commercial » Automatic Operators » Electrohydraulic » 4630 Series » LCN | Schlage Commercial » Automatic Operators » Electromechanical » 8200 Series » Falcon | Schlage Commercial » Automatic Operators » Electromechanical » Benchmark » LCN | Schlage Commercial » Automatic Operators » Electromechanical » Senior Swing » LCN | Schlage Commercial » Automatic Operators » Pneumatics » 2610 Series » LCN | Schlage Commercial » Automatic Operators » Pneumatics » 4810 Series » LCN | Schlage Commercial » Door Controls » Automatic Operator » 7900 Series » LCN | Schlage Commercial » Door Controls » Automatic Operator » 7980 Series » LCN
Will the 4600 series operator be damaged if activated when the door is locked?
Any good secure setup and installation should be getting an open signal that has already gone through credential access first (ex……card reader, keypad, Key switch) and ignoring a locked door. ...
Schlage Commercial » Automatic Operators » Electrohydraulic » 4630 Series » LCN