Does the A14 series meet UL 10C?
Yes, A14-Series Doors meet fire rating requirements. They are listed for installations requiring compliance to NFPA252-1999 and UL-10C....
Schlage Commercial » Doors and Frames | Schlage Commercial » Doors and Frames » Doors | Schlage Commercial » Doors and Frames » Doors » A14 Series | Schlage Commercial » Doors and Frames » Doors » A14 Series » Steelcraft
How do I program my device?
The programming processes for Allegion devices can be both product and features specific.  Some products programming processes are electronic in nature, others are physical in nature.  ...
Schlage Commercial » Automatic Operators | Schlage Commercial » Biometrics | Schlage Commercial » Credentials | Schlage Commercial » Door Controls | Schlage Commercial » Doors and Frames | Schlage Commercial » Electronic Locks | Schlage Commercial » Exit Devices | Schlage Commercial » Key Systems | Schlage Commercial » Mechanical Accessories | Schlage Commercial » Mechanical Locks | Schlage Commercial » Power Supplies | Schlage Commercial » Readers | Schlage Commercial » Security Management | Schlage Commercial » Software | Schlage Commercial » System Components | Schlage Commercial » Falcon | Schlage Commercial » Glynn-Johnson | Schlage Commercial » Ives | Schlage Commercial » LCN | Schlage Commercial » Schlage | Schlage Commercial » Schlage Electronics | Schlage Commercial » Steelcraft | Schlage Commercial » Von Duprin
How do I order the LM9300 multipoint lock?
The mortise lock would be priced from the Schlage commercial PB. (Please refer to the current PB for details) There is an add to the base price for the multipoint lock option.The rods, door and door f...
Schlage Commercial » Doors and Frames | Schlage Commercial » Doors and Frames » Doors | Schlage Commercial » Doors and Frames » Frames | Schlage Commercial » Mechanical Locks » Mortised | Schlage Commercial » Mechanical Locks » Mortised » L9000 Series | Schlage Commercial » Mechanical Locks » Mortised » L9000 Series » Schlage | Schlage Commercial » Mechanical Locks » Mortised » LM9300 Series | Schlage Commercial » Mechanical Locks » Mortised » LM9300 Series » Schlage | Schlage Commercial
What is included in a 154 mullion stabilizer kit?
The kit contains components for two doors and a mullion.  The kit has two door portions, two mullion portions, and shims.  These interlocking stabilizers sets are furnished standard with alu...
Schlage Commercial » Doors and Frames
What Allegion components are ITS/WHI Intertek approved for Windstorm/Tornado Resistant openings?
The Steelcraft Paladin Series doors and frames are available in compliance with FEMA 361 and ANSI ICC500-2014.  The door system may include other approved Allegion hardware and components that ar...
Schlage Commercial » Automatic Operators | Schlage Commercial » Doors and Frames | Schlage Commercial » Exit Devices | Schlage Commercial » Mechanical Accessories | Schlage Commercial » Mechanical Locks | Schlage Commercial » Falcon | Schlage Commercial » Glynn-Johnson | Schlage Commercial » Ives | Schlage Commercial » LCN | Schlage Commercial » Schlage | Schlage Commercial » Steelcraft | Schlage Commercial » Von Duprin | Schlage Commercial » Zero | Schlage Commercial » Sealing Systems
How do I find a local locksmith or service person for my Allegion products?
At us.allegion.com, the home page has a tab at the top of page titled Locators.  Click on that tab, then enter your zip code, click submit ...
Schlage Commercial » Door Controls | Schlage Commercial » Doors and Frames | Schlage Commercial » Exit Devices | Schlage Commercial » Glynn-Johnson | Schlage Commercial » Von Duprin | Schlage Commercial » Zero
What are the 13 fire rated opening inspection points?
As of 20212, the NFPA 80 Chapter 5 details the following 13 fire door assembly inspection points:1. Labels are present and legible2. No holes or breaks in the door or frame3. Glazing and glass kit/gla...
Schlage Commercial » Doors and Frames
What kind of door prep is acceptable for fire door modification in the field?
The following job site preparations are acceptable for onsite modification of a fire door assembly:Holes for surface-applied hardware, fasteners, labeled viewers, function holes for mortise locksRound...
Schlage Commercial » Doors and Frames | Schlage Commercial » Mechanical Locks » Cylindrical | Schlage Commercial » Mechanical Locks » Mortised » L9000 Series