Wire for an aptiQ Reader
”
RELATED FAQS
Question
Answer
Can we do TW on swing clear hinges?
Resolution:
Swing clear hinges are available with TW (through wire).:
What wire gauge is recommended for LCN hardwired actuators?
Resolution:
LCN recommends an 18 AWG (minimum) wire size (gauge) to the 8310 Series hardwired actuators.:
What wires are the activation inputs for the Senior Swing?
Resolution:
The current (digital control box) activation input wiring harness (# 761464-00) is included in the Sr. Swing parts bag (-518), and has 4 wires in it, Black, White, Yellow, & Gray. ...:
Can the credential reader be changed on a CO-Series lockset?
Resolution:
A Credential Reader MAY be replaced with another Credential Reader of the same type; however, a Factory Default Reset must be performed before the lock will function properly.:
What is the reader address for a master F-Series HandKey II?
Resolution:
A F-Series HandKey II can be operated as a stand-alone access control station, as a network master enrollment station, or as a networked access control station which receives and processes co...:
Where does the hold open switch on the 4630 / 4640 wire into on the 1-24 single terminal strip?
Resolution:
The 4600 hold open switch (for the new 1-24 single terminal strip I/O board) wires into terminals 2 and 6 or 4 and 6.:
What cleaning suggestions would you provide to a customer should the hand reader be exposed to blood?
Resolution:
To clean the platen on a hand reader, apply a Windex-like product with a clean, soft cloth and allow it to air dry. The hand reader platen overlay has an anti-microbial surface. Should ...:
What is the difference between the EPT 2 and the EPT 10?:
Resolution:
The EPT2 has (2) 18 gauge wires and the EPT10 has (10) 24 gauge wires. Even though they are 18 gauge or 24 gauge wires they are special high stress, high flex, & high current wires specifically u...:
How many Von Duprin QEL devices can be connected to a power supply?
Resolution:
Product Ordered before 7/10/2012 - Product identified by no label on QEL motor. You must use the 900-2Q option board with the PS900 power supplies to operate the QEL devices. The attached ta...:
Are the FingerKey DX fingerprint readers still available for purchase?
Resolution:
The FingerKey product line was officially discontinued as of February 2011. The process began in September 2010 however, as of February 2, 2011, no new orders were accepted and any parts left...:
What are the model numbers for the new Schlage and XceedID wall mounted credential readers?
Resolution:
The Legacy wall mounted readers are replaced as shown in the table below: The MTMS15 and MTMSK15 did not have any prior models that it replaced.:
What is the "HOST BITS" setting on a Hand Reader with an Ethernet Module?
Resolution:
Handreaders require a static (fixed) IP address; this means you have to set its IP address, subnet mask and default gateway.These are usually assigned or issued by your local network administrator....:
How are actuators wired to a 7900 or 7980 series control box?
Resolution:
The "common" of all the actuator switches will connect to terminal 10. The N.O. (normally open contact) will connect to Terminal 5, 6, 7 or 8 depending on which control box is used and the function...:
Can you connect an external horn to a Chexit device?
Resolution:
Chexit devices shipped prior to 8-24-2015 with solenoid driven:Use the external alarm contact, blue and brown wire on Chexit device.Connect the blue wire to the red wire and connect the brown wire ...:
What does a Warning 80 or 17 mean on a F-Series hand reader?
Resolution:
When you see a Warning 80 or Warning 17 on a HandKey or a HandPunch, it may mean that the lithium battery is low. The first step is to try a warm boot on the reader to see if that h...:
Can I bypass the circuit board on a M420 M450 or M490: Unsupported voids warranty
Resolution:
No the M400 series of mag locks may not operate direct wiring the power to the coils . Bypassing the circuit board or direct wiring the coils is not supported and voids the warranty ...:
Which direction does the Von Duprin CX 10 wire harness plug into the board?
Resolution:
Chexit devices shipped after 8-24-2015 with motor driven has a twelve wire connector wires and is keyed and can only plugged into the Chexit module in one direction. Chexit d...:
Do the electric removable mullions come with a quick connector?
Resolution:
The Von Duprin electrified steel mullions, 4854 and 9854 come with a quick connector that connects the electric strike wires from the mullion to the frame through the top fitting. ...:
What wire gauge and run is recommended for Von Duprin electric latch retraction EL device?
Resolution:
:
Can you have a security stud hinge with a TW option?
Resolution:
The Security Stud and TW4/8 (through wire) options are in the same location on a hinge and cannot be ordered together.:
How do you find the serial number of a biometric F-Series handpunch or Handkey II?
Resolution:
Yes, press the * (asterisk) key 10 times on the reader. The serial number will be displayed. A second way of locating the serial number on the reader is to visually check...:
On a HandPunch when the "Time and Attendance" mode is activated, how do you perform a "Department Code" Function?
Resolution:
On a biometric F-Series hand reader, if the "Time & Attendance" mode is activated:press your ID then #, choose from 1-IN 2-OUT 3-BACK (press either 1 or 2 or 3); the reader wi...:
What is the power output of a 4600 operator?
Resolution:
The 4600 Series operator has both a 12VDC and 24VDC output rated at 1A (combined load) to power strikes, maglocks, and other devices, but an EL device must have a separate Power Supply for motorize...:
What is the part number for the 6000 series electric strike 24VDC solenoid?
Resolution:
The Von Duprin 6000 series electric strike can be converted by ordering the appropriate kits below. Kits include the solenoid, plunger, spring, and washer. 6000 Series solenoid Kit 1...:
What is the part number for the CX wiring assembly?
Resolution:
The part number for "CX Wiring Assembly" also called "Ten Wire Connector" is 112018-00. :
How can a TK400 be reset to factory defaults
Resolution:
If a factory default reset (FDR) is absolutely needed, you MUST temporarily replace the credential reader with another reader that has a Schlage Button. This should be rarely if ever required. T...:
How many wires does the Von Duprin E7500 lock body have and how are they used.
Resolution:
The Von Duprin E7500 has a total of 8 wires. Two power wires. 12VDC solenoid has yellow wires. 24VDC solenoid has black wires. Six switch wires. Latchbolt monitor switch has three wires,...:
Does the ND lock have an RX option?
Resolution:
The ND lock is available with an RX option: When ordering a complete ND lock specify RX when the request to exit (RX) switch is required. The ND80EL, ND80EU, ND96EL, ND96EU, ND12EL, ND12E...:
Why is the Von Duprin PS873 power supply buzzing or chattering?
Resolution:
Some transformers in the power supplies provide a little humming noise and that is normal. If the humming in Von Duprin PS873 power supply is loud follow these steps. Remove the load from the outp...:
How do you specify an exit alarm ALK with a hard wire to the power supply?
Resolution:
All new 22, 33/35A and 98/99 series exit devices with exit alarm ALK option can be hard wired to the PS902 power supply as a standard feature.:
Where can I find wiring information for the Chexit?
Resolution:
Chexit devices shipped before 8-24-2015 with solenoid driven:Attached are the single and double door wiring , cable voltage reading documents for trouble shooting, and the installation in...:
Why is the battery draining so quickly on an AD-Series lock with a Keypad ONLY (KP) credential reader?
Resolution:
A Technical Note has been generated to document one method of measuring battery current. See the attachment HERE.:
What gauge wire is needed for CX red and black power wires?
Resolution:
For Product Shipped prior to 8-24-2015 with solenoid and EPT or Door Loops: a. 0-100 ft, use #14 Gauge Wire ...:
How do you route the wires for an E996L trim through the exit device?
Resolution:
The wires run through the device out to the EPT. See step 7 on page 5 of E996L instructions.:
What are the Falcon T lock electrical requirements?
Resolution:
Prior to June 2011 the T lock only supported 24V and the electrical requirements were as follows: 0.185 amp @ 24VDC Wire Gage 22 AWG See wiring diagram here - (Previous 2 wire versi...:
Can the AD-Series and CO-Series magnetic card credential readers be set to read data from different magnetic card tracks?
Resolution:
Customers will need to use the Schlage Utility Software (SUS) on the HHD lock programming device to set the desired magnetic track to be read for access control, if not using default Track 2&n...:
Falcon MA lock wire color.
Resolution:
Solenoid: Black (2 wires) RX (monitors both sides) Normally Open: Green (pin 6 when connector included) Common: Orange (pin 5 when connector included) The current version o...:
What size wire and run is recommended when using a PS914-2RS?
Resolution:
For Product Shipped Prior to August 2012 using the old (black) potted module:a. 0-100 ft 14 gauge wireb. 0-200 ft 12 gauge wire&nbs...:
Why does a biometric hand reader display "Time restriction" ?
Resolution:
A biometric HandPunch will display "Time restriction" if you are trying to punch in or punch out outside of the times allowed for this. An employee will see the message, "Time restrictio...:
Do you have a micro-switch with orange wires?
Resolution:
The micro-switch with two orange wires is probably the Chexit switch assembly for devices shipped prior to 8-24-2015 with solenoid driven, part number 13-065-00. :
Does the wire size of an EPT affect the operation of an EL device?
Resolution:
Since most wire transfer devices such as an EPT or electric hinges cannot provide large gauge wires, we take the small gauge wire into account when determining the overall wire size for the device....:
Does F-series SDK support E-Series hand readers?
Resolution:
Yes, the F-series SDK includes commands that will work with the E-series, but not all SDK commands are compatible with the E-series. The Programming Guide (which is included with the SDK) lists wha...:
When should I update the firmware in my AD Series or CO Series products?
Resolution:
Steps to determine what firmware version your products are currently using AND if a firmware update is suggested: 1) Use the Hand Held Device (HHD) and Schlage Utility Software (SUS) applicat...:
What are the pin outs on the RS232/J4 connector on a F3-style main board in a biometric F-Series hand reader?
Resolution:
The RS232 pin out on a F3-style main board for a F-Series HandKey or a F-Series HandPunch to the J4 connector is Pin 1 (Pin 1 is the farthest pin from the edge of the board) is Groun...:
What are the 3 wires on the Falcon AE switch?
Resolution:
For 24/25 devices per instructions : Violet - Normally Open Black - Common Gray - Normally Closed:
Are the wires on a Von Duprin 6000 series electric strike polarized?
Resolution:
The wires on 6000 series electric strike solenoid are non polarized.:
What would cause a Senior Swing to open only 10 degrees and then close?
Resolution:
Issue/Symptom – upon receiving an activation input the Sr Swing gearbox opens only about 10 degrees and then returns to the close position. Unit will never learn opening nor function pro...:
Why is my Von Duprin Chexit device not lighting up or arming?
Resolution:
Devices were shipped from the factory with solenoid driven prior to 8-24-2015. First confirm that you are using a PS873 or PS914 power supply.Measure the DC voltage at the ten wire hardness a...:
What are the wire gauge and length requirements for QEL devices?
Resolution:
Use #18 gauge wire up to 200 feet maximum distance from PS900 x 900-2Q power supply to the QEL exit device. The new QEL+ no longer requires the 900-2Q board but still needs a different option board...:
Is the wiring harness found in both the KR 4854 and standard 4854 mullions?
Resolution:
The male and female receptacle wire assemblies (wiring hardness) are included in 48/9854 and KR48/9854 mullions. The wiring harness is the same in a 4854 and 9854 mullions. 105987 is the part n...:
How do I connect External Inhibit wires on Chexit?
Resolution:
Chexit devices shipped prior to 8-24-2015 were solenoid driven: A normally closed card reader contact, key pad contact or any other control contact connects to the G...:
What is the wire gauge on the motor driven L9000 mortise locks?
Resolution:
Supply wires - 24AWGRX wires - 20AWGLX wires - 20 AWG:
Will the door unlock if a Von Duprin CX 98 / 99 Chexit device is deactivated with card reader and has a 996LBE trim?
Resolution:
When a CX99L-BE is not armed the exterior 996L BE lever trim will be free to retract the CX latch for entrance. When the CX99-L BE is armed the exterior 996L BE lever will not move and...:
How do I connect the external inhibit option for the Chexit?
Resolution:
For Chexit devices shipped after 8-24-2015 with motor driven connect your normally closed contact from access control system between green and red on the twelve field wire ...:
What are the steps I need to take in order to do a card emulation test between biometric hand readers?
Resolution:
If an access control system is not available to test the card output on a hand reader, this card emulation test can be done to verify the card format is correct. These steps will guide you in...:
Is there a template that shows where to drill the hole for E/EL/SS/RX/LX/CX wires?
Resolution:
The hole should be drilled in the field once the end cap is located on the door. It is a 5/8" hole, that is located 5/16" from the end of the mechanism case. See installation instruction of t...:
What process should be followed to change the Credential Reader type on a AD-Series lock?
Resolution:
The process to change the Credential Reader on an AD-Series lock is as follows: Note: To ensure firmware compatibility of the lock and reader, it is important that the firmware in the LOCK and the...: