Wire for an aptiQ Reader

RELATED FAQS

Question
Answer
Swing clear hinges are available with TW (through wire).
LCN recommends an 18 AWG (minimum) wire size (gauge) to the 8310 Series hardwired actuators.
The current (digital control box) activation input wiring harness (# 761464-00) is included in the Sr. Swing parts bag (-518), and has 4 wires in it, Black, White, Yellow, & Gray. This harness p...
On power-up the CO-Series locksets will provide 5 quick RED Schlage Button flashes and 5 quick beeps to indicate that the electronics (credential reader) has been changed.  In order to recover...
When/If the electronics (Credential Reader) changed on a CO-Series lockset, the lock will respond with 3 RED Schlage button flashes and 3 beeps for any key press or credential presentation.&nb...
CO Reader Modules cannot be replaced by Reader Modules with a different credential type; for example, a magnetic swipe credential reader cannot be replaced with a proximity credential rea...
A Credential Reader MAY be replaced with another Credential Reader of the same type; however, a Factory Default Reset must be performed before the lock will function properly.
 A F-Series HandKey II can be operated as a stand-alone access control station, as a network master enrollment station, or as a networked access control station which receives and processes co...
The 4600 hold open switch (for the new 1-24 single terminal strip I/O board) wires into terminals 2 and 6 or 4 and 6.
RX wiring on all L9000 locks with RX switch manufactured after January 2, 2017:The L-Series switched to a handed modular three-wire request to exit (RX) switch. This change was originally completed...
Specific to the RX switch installed into the L9080EL/EU and L9082EL/EU and L9000 mechanical locks prior to January 2, 2017:ALL PART NUMBERS BELOW DISCONTINUEDThe L-Series switched to a three-wire r...
To clean the platen on a hand reader, apply a Windex-like product with a clean, soft cloth and allow it to air dry.  The hand reader platen overlay has an anti-microbial surface.  Should ...
The EPT2 has (2) 18 gauge wires and the EPT10 has (10) 24 gauge wires.  Even though they are 18 gauge or 24 gauge wires they are special high stress, high flex, & high current wires specifically u...
Product Ordered after 7/10/2012 - Product identified by label on QEL motor You no longer need to use the 900-2Q option board (no longer available) with the PS900 power supplies to ...
Product Ordered before 7/10/2012 - Product identified by no label on QEL motor. You must use the 900-2Q option board with the PS900 power supplies to operate the QEL devices.  The attached ta...
The FingerKey product line was officially discontinued as of February 2011.  The process began in September 2010 however, as of February 2, 2011, no new orders were accepted and any parts left...
         
  The Legacy wall mounted readers are replaced as shown in the table below:  The MTMS15 and MTMSK15 did not have any prior models that it replaced.
Handreaders require a static (fixed) IP address; this means you have to set its IP address, subnet mask and default gateway.These are usually assigned or issued by your local network administrator....
The "common" of all the actuator switches will connect to terminal 10. The N.O. (normally open contact) will connect to Terminal 5, 6, 7 or 8 depending on which control box is used and the function...
Chexit devices shipped after 8-24-2015 with motor driven:Use the Alarm Relay Contacts on Field Wiring Cable, blue and brown wires of the Chexit device.Connect the blue wire to +24VDC (red wire on F...
Chexit devices shipped prior to 8-24-2015 with solenoid driven:Use the external alarm contact, blue and brown wire on Chexit device.Connect the blue wire to the red wire and connect the brown wire ...
When you see a Warning 80 or Warning 17 on a HandKey or a HandPunch, it may mean that the lithium battery is low.  The first step is to try a warm boot on the reader to see if that h...
For F-series HandPunch devices:    The top-mount PROX reader is available only for the HP-3000 reader.  The PROX reader on a HandPunch 3000 is able to read standard 26-bit ...
Chexit devices shipped after 8-24-2015 with motor driven has a twelve wire connector wires and is keyed and can only plugged into the Chexit module in one direction.Chexit devices shipped...
The Von Duprin electrified steel mullions, 4854 and 9854 come with a quick connector that connects the electric strike wires from the mullion to the frame through the top fitting.  ...
  For Product Shipped Prior to August 2012 using the old (black) potted module: a.       0-100 ft 14 gauge wire b.      0-200 ft 12...
 
The E6 version of the E-Series biometric Hand Reader holds 256 user hand templates.  To accommodate a larger user base, the hand reader can be configured to hold up to 27,904 user hand ...
The 8310-865 RF receiver connection to the Falcon 8200 operator are: RED and BLACK power wires on the receiver connect to the 12V AC terminals on the Falcon operator. The WHITE wire from the COM t...
See Point to Point wiring diagram here.
The Security Stud and TW4/8 (through wire) options are in the same location on a hinge and cannot be ordered together.
Yes, press the * (asterisk) key 10 times on the reader.  The serial number will be displayed.  A second way of locating the serial number on the reader is to visually check...
On a biometric F-Series hand reader, if the "Time & Attendance" mode is activated:press your ID then #, choose from 1-IN  2-OUT  3-BACK  (press either 1 or 2 or 3); the reader wi...
The 4600 Series operator has both a 12VDC and 24VDC output rated at 1A (combined load) to power strikes, maglocks, and other devices, but an EL device "always" has to have a separate PS914-2RS Seri...
The Von Duprin 6000 series electric strike can be converted by ordering the appropriate kits below.  Kits include the solenoid, plunger, spring, and washer. 6000 Series solenoid Kit 12VDC -...
The part number for "CX Wiring Assembly" also called "Ten Wire Connector" is 112018-00.
The TK400 kit contains an PIM400-TD2 and a WPR400-DT (Dummy Trim) and charger. The WPR400-DT reader has no electronics it is an empty plastic shell. Since the WPR400-DT does not have electronics ...
If a factory default reset (FDR)  is absolutely needed, you MUST temporarily replace the credential reader with another reader that has a Schlage Button.  This should be rarely if ever required. T...
You must replace the entire RX switch assembly for Chexit devices shipped after 8-24-2015 with motor driven.
The part number for the RX switch pig tail (black plug) with two orange wires only for Chexit devices shipped prior to 8-24-2015 with solenoid driven is 991338-00. 
The Von Duprin E7500 has a total of 8 wires. Two power wires. 12VDC solenoid has yellow wires. 24VDC solenoid has black wires. Six switch wires. Latchbolt monitor switch has three wires,...
The ND lock is available with an RX option:When ordering a complete ND lock specify RX when the request to exit (RX) switch is required.The ND80EL, ND80EU, ND96EL, ND96EU, ND12EL, ND12EU electrifie...
Prom Version Release Date Reader Type Model New Functions or Options Summary 265 2006 F-Series All Improvements to remove the occurrences of random resets on Ha...
Some transformers in the power supplies provide a little humming noise and that is normal. If the humming in Von Duprin PS873 power supply is loud follow these steps. Remove the load from the outp...
All new 22, 33/35A and 98/99 series exit devices with exit alarm ALK option can be hard wired to the PS902 power supply as a standard  feature.
Chexit devices shipped after 8-24-2015 with motor driven:Attached is the installation instructions of the the Von Duprin Chexit devices that includes the wiring diagrams.Installation Instructions&n...
Chexit devices shipped before 8-24-2015 with solenoid driven:Attached are the single and double door wiring , cable voltage reading documents for trouble shooting, and the installation in...
All Keypad ONLY credentials with firmware versions between 2.9.2 and 2.11.0 should be updated to the latest firmware available at www.schlage,com/support.
A firmware issue with Keypad ONLY credential firmware, versions 2.9.2 through 2.11.0 and manufactured between 9-9-2010 and 1-5-2011 will exhibit poor battery life.
The Keypad ONLY credential Reader (KP) can prevent the reader from entering its low power sleep mode - with firmware versions 2.9.2 through 2.11.0
A Technical Note has been generated to document one method of measuring battery current. See the attachment HERE.
For devices shipped after 8-24-2015 with motor driven:  a.       0-200 ft, use  #18 gauge wire b.      0-500 ft, use #14 gauge wir...
For Product Shipped prior to 8-24-2015 with solenoid driven:          a.       0-100 ft, use #14 Gauge Wire      b.&n...
The wires run through the device out to the EPT. See step 7 on page 5 of E996L instructions.
As of June 2011 the electrified T locks can support 12 or 24 Volts.  You do not need to specify 12 or 24 when ordering since the solenoid is capable of either voltage out of the...
Prior to June 2011 the T lock only supported 24V and the electrical requirements were as follows: 0.185 amp @ 24VDC Wire Gage 22 AWG See wiring diagram here - (Previous 2 wire versi...
Customers will need to use the Schlage Utility Software (SUS) on the HHD lock programming device to set the desired magnetic track to be read for access control, if not using default Track 2&n...
Solenoid: Black (2 wires) Case side RX Normally Open: Green Normally Closed: Orange Cover side RX Normally Open: Gray Normally Closed: Red Common: Yellow
Refer to the MA RX diagram here for more information.
For Product Shipped Prior to August 2012 using the old (black) potted module:a.       0-100 ft 14 gauge wireb.      0-200 ft 12 gauge wire&nbs...
A biometric HandPunch will display "Time restriction" if you are trying to punch in or punch out outside of the times allowed for this.  An employee will see the message, "Time restrictio...
The micro-switch with two orange wires is probably the Chexit switch assembly for devices shipped prior to 8-24-2015 with solenoid driven, part number 13-065-00. 
Since most wire transfer devices such as an EPT or electric hinges cannot provide large gauge wires, we take the small gauge wire into account when determining the overall wire size for the device....
Yes, the F-series SDK includes commands that will work with the E-series, but not all SDK commands are compatible with the E-series. The Programming Guide (which is included with the SDK) lists wha...
When new product(s) are added to an existing installed customer site, all devices at that site should be updated to the latest firmware revision that is available for the most consistent user exper...
Whenever an AD Series credential reader is upgraded with new or different credential types or replaced in the field, be sure to update. Lock firmware and reader firmware are packaged together so ...
Search the product library for firmware associated with your installed product to obtain the latest updates.  
Go to the Schlage support site to download the latest firmware package  - www.schlage.com/support  
Steps to determine what firmware version your products are currently using AND if a firmware update is suggested:1) Use the Hand Held Device (HHD) and Schlage Utility Software (SUS) application to ...
The RS232 pin out on a F3-style main board for a F-Series HandKey or a F-Series HandPunch to the J4 connector is Pin 1 (Pin 1 is the farthest pin from the edge of the board) is Groun...
For the older 17/18 or current 19 device per instructions :  Red - Normally Open  Green - Common   Black - Normally Closed
For 24/25 devices per instructions :   Violet - Normally Open   Black - Common   Gray - Normally Closed
The wires on 6000 series electric strike solenoid are non polarized.
Devices were shipped from the factory with motor driven after 8-24-2015. First confirm that you are using PS900 series (902,904,906 or 914) power supply.      1. Mea...
Devices were shipped from the factory with solenoid driven prior to 8-24-2015.  First confirm that you are using a PS873 or PS914 power supply.Measure the DC voltage at the ten wire hardness a...
Use #18 gauge wire up to 200 feet maximum distance from PS900 x 900-2Q power supply to the QEL exit device. The new QEL+ no longer requires the 900-2Q board but still needs a different option board...
The male and female receptacle wire assemblies (wiring hardness) are included in 48/9854 and KR48/9854 mullions. The wiring harness is the same in a 4854 and 9854 mullions. 105987 is the part n...
Chexit devices shipped prior to 8-24-2015 with solenoid driven: A normally closed card reader contact, key pad contact or any other control contact connects to the Green an...
Supply wires - 24AWGRX wires - 20AWGLX wires - 20 AWG
When CX99L-BE is not armed with key cylinder on the device or shunted by card reader, the exterior 996LBE lever trim will release.
For Chexit devices shipped after 8-24-2015 with motor driven connect your normally closed contact from access control system between green and red on the twelve field wire ...
If an access control system is not available to test the card output on a hand reader, this card emulation test can be done to verify the card format is correct.  These steps will guide you in...
The hole should be drilled in the field once the end cap is located on the door.  It is a 5/8" hole, that is located 5/16" from the end of the mechanism case. See installation instruction of t...
The process to change the Credential Reader on an AD-Series lock is as follows: Note: To ensure firmware compatibility of the lock and reader, it is important that the firmware in the LOCK and the...