Will an ALK sound when the exterior trim is used to enter from the pull side?
Resolution:
The ALK exit alarm will sound when the exterior trim is used to enter from pull side without using access control when an LX latch bolt monitor switch is used instead of RX push bar monitor switch.:
Why is my latch not retracting when I depress the push pad on an XP98/99 device?
Resolution:
Pushing on the push bar or activating the EL/QEL or the trim on Von Duprin XP98/99 exit device does not retract the latch, it releases the latch only. Door must be pushed or pulled when device o...:
What arm can I use for the old LCN 4030/4130 closer?
Resolution:
The old 4030/4130 closers and arms are obsolete, there is nothing to replace them. No arm from other closers will fit There is no closer that can replace the old 4030 series closer with the exa...:
Can a Senior Swing 9550 be mounted on an unequal pair of doors?
Resolution:
"PUSH SIDE" application: Minimum 52" wide pair, with neither door being less than 21" wide. "PULL SIDE" application - For Product Shipped...:
What is the minimum and maximum reveal for a 9500 Series Senior Swing operator?
Resolution:
The 9542, 9553, 9563 surface mounted Senior Swing with a regular arm, mounted on the push side of the door, can handle a reveal from 1 1/8" up to 10". The 9542, 9553, 9563 surface mounted Senior S...:
What is the Senior Swing 9540 REG arm part number?
Resolution:
The part number for the threaded rod "only" on the Senior Swing regular arm is 9540-82, 9550-82, or 9560-82 or -82L for the long rod option. The part number for the threaded rod, turn buckles, an...:
Do you need Double Egress arm to install a 4040SE on the Push Side of a door?
Resolution:
The 4040SE uses the regular arm for any Push Side mounting (minimum 28" door width). ST-2788 (a special arm and track) can be used to mount a 4040SE on the Push Side of a smaller (narrow) door. Sm...:
What is the mounting difference between a 2010 closer and a 2030 closer?
Resolution:
The 2010 and 2030 closer are not the same. The 2010 Series closer uses the (larger) 4010 cylinder which requires a 4" minimum frame tube to mount in. The 2030 uses the (narrow) "Pacer" cylinder...:
What are ElectroMechanical Automatic Operators?
Resolution:
ElectroMechanical Automatic Operators are designed to automatically open when activated. The Benchmark Series are Medium Duty "Commercial" automatic operators, often used on of...:
Why does the ND40 stay locked after egress?
Resolution:
There is potential for ND40/ND44's manufactured around March 2011 to remain locked after egress, or after the latch is depressed. There was an issue with the keycam that created a bind when l...:
Can you mount a 4041 Cush arm with a EDA arm template and get 180 degrees opening?
Resolution:
The dead stop post would need to be removed and the 4040/4040XP EDA mounting template for 180° would be followed.:
How can you tell the hand of a door closer?
Resolution:
First you need to determine if the closer is handed. A handed door closer will only have a single shaft on one side of the closer for the arm to attach to. If the closer is handed...:
How do you install the LCN 9540 Senior Swing (REG) push arm?
Resolution:
When installing the arm; the gearbox shaft and door must be at the (+90°) full open position. The following step are used to install the Sr. Swing (REG) push arm. Install t...:
What is the part number for the 4642 cylinder only?
Resolution:
The 4600 cylinder only part numbers are: 4640 Series -- 4642-3971 4630 Series -- 4631-3971 The 4642-3971 is for push side only and the 4631-3971 is for pull side only.:
My COR is not allowing my inactive leaf with push side overlapping astragal to close first.
Resolution:
Astragal must be applied to pull side of active leaf, since placing the stragal on the inside of the inactive leaf will interfere with the active door closing.:
The Von Duprin 98 or 99 ALK kit will not sound the horn
Resolution:
Followings are the reason for 98/99 exit alarm ALK not sound when push bar is activated. Make sure key switch on exit alarm ALK is turned on, wait for 20 seconds before you activating the pushba...:
Are the 4011 and 4021 closers the same?
Resolution:
The 4011 and 4021 use the same closer body but other components are different. The 4011 mounts "pull" side. When ordered as a 4011, it comes with a 6-3/8" rod and shoe, pull side instruction...:
Will a Senior Swing work with swing clear hinges?
Resolution:
Push Side Surface Mount Senior Swing can be used with swing clear hinges, standard butt hinge/offset pivot templating. Pull Side Surface Mount Senior Swing cannot be...:
Common wiring diagrams
Resolution:
Electronic Protocols: Access Control Door with electric trim Access Control with electric strike Access control with electric strike and LCN 460...:
What is a surface mounted door closer?
Resolution:
Surface Mounted door closers are the most durable and common type of door closer. Mounted to the surface of the door or frame Can be configured (through installation or arm type) to meet a...:
How to adjust a 4010 hold open arm?
Resolution:
The correct method (process) for setting the hold open is: The 4010 hold open arms are handed, verify correct hand arm. (R or L stamped on main arm) Loosen the hold open nut. Opened the door ...:
Can the Falcon 25-V be cut to fit on a 2' door?
Resolution:
The standard Falcon 25V vertical rod cannot be cut to fit on a 2 feet door opening. This device requires 2' 7 1/8" minimum door opening. Falcon offers a device that can be used on a 2 feet doo...:
How do you order a Senior Swing header for a 2810 on one leaf and a 2010 on the other?
Resolution:
LCN does offer a 2810 Senior Swing / 2010 manual closer combo for a pair of doors. Both units contained within the same Senior Swing header. To order a paired operator with a 2810 o...:
What is a 320G door closer?
Resolution:
The "320G" is the # on a UL sticker attached to the arm of most LCN door closers, and is not a door closer model number. The "320G" means that the arm is not a mechanical hold open device and OK t...:
Will a 4040 Hw/PA hold open at 180°?
Resolution:
The 4041 Rw/PA and the Hw/PA have the same template. The only difference is the arm. The 4041/4040XP Hw/PA, if mounted to the 180° template, will hold the door open at 180°. Rw/PA is Regular A...:
How do you remove the cylinder from an A series knob?
Resolution:
*The older wafer style locks did not use a knob catch. The chassis must be disassembled before the knob can be removed because it uses the wafer lock chassis spindle.:
PP
Resolution:
Reinforcements for Push / Pull plates; Push Pull Reinforcement, Reinforcement:
Can a 4010 be used on the push side of the door like a 4020?
Resolution:
The 4010 and 4020 use the same door closer cylinder, the rod and shoe and covers are different. To use a 4010 cylinder as a 4020, you will need a 4020-79 rod and shoe and a 4020-72 cover. To us...:
What different types of door coordinators are available?
Resolution:
There are 2 types of door coordinators available: Bar Coordinators (Ives COR Series): Surface mounted to the bottom surface of the frame soffit. The active door lever, located nearest to th...:
What is the difference between a 4410ME and a 4310ME?
Resolution:
The 4410ME (4414ME) is a double arm unit that mounts on the push side of the door. The 4310ME (4314ME) is a single arm/track unit that mounts on the pull side of the door.:
CLEARANCE
Resolution:
Distance fro a PA SHOE to the push side of door or from the pull side of door to the wall:
How do you install the LCN 9530 Senior Swing (STD) pull arm?
Resolution:
When installing the arm; the gearbox shaft and door must be at the (+90°) full open position. The following step are used to install the Senior Swing (STD) pull arm. Install...:
What is clear opening width?
Resolution:
Clear Opening Width for swinging doors is measured (with the door open 90 degree) from the face of door to stop soffit on strike jamb. &nbs...:
What is the hinge backset for 1 3/4" thick door?
Resolution:
Hinge backset is the dimension from the leading edge of the hinge to either the stop on the frame or to the stop face (push side) of the door. For operating clearance, the hinge backset on the d...:
How do I order an 88 rim to accept NL cylinder and pull by others?
Resolution:
Order the device as 88 NL less trim. The cylinder will be mounted to the face of the door. Use templates 10156 and 40015.:
How do you adjust a door closer?
Resolution:
How to: What are the steps to adjust a door closer? Facts: All LCN and FALCON door closers will have 3 regulating valves and a spring adjustment. All cl...:
In what direction should the hold open nut be pointing for a 4041 H closer, up or down?
Resolution:
Make sure that the hold open nut is not on upside down. The orientation of the hold open nut depends on the mounting. On a Top Jamb "Push Side" mount, the hold open nut would poi...:
EXIT FUNCTION 02
Resolution:
Push/Pull, Dogged Device (BHMA Exit Function):
Why is the Von Duprin 55 or 88 series crossbar sagging?
Resolution:
There are a number of reasons the Von Duprin 55 or 88 series cross bar may not operate properly: The hinge case spring lifts both lever arms and the crossbar. To check spring, pu...:
Why is the Von Duprin exit alarm ALK going into alarm on it's own?
Resolution:
The following may cause the ALK to go into alarm: Make sure red and blue wires on the RX switch are connected to the exit alarm ALK terminal block and yellow wire is taped off. Check the red an...:
How do I determine the hand of a door?
Resolution:
Go to the push side of the door opening. See above illustration. If door swings out to the left, it needs a left hand door closer. If door swings out to the right, i...:
What is the difference between the Senior Swing 9540 and 9530 Series power operators?
Resolution:
The 9542 is the single door operator that mounts on the "push side" of the opening with a REG arm. The 9531 is the single door operator that mounts on the "pull side" of the opening with a STD arm...:
Can a 4040 regular mount installed on the pull side and a Glynn Johnson 90 be mounted together?
Resolution:
The LCN 4041/4040XP and the Glynn Johnson 90 series can be mounted in conjunction with each other without a special template. The 4040 door closer is on the pull side of the door and the GJ 90 is ...:
What is the difference between an LCN CUSH arm, and an LCN EDA arm?
Resolution:
EDA ARM - The EDA arm is a heavy duty parallel arm mount. The degree of door opening is determined by the template used for mounting. EDA arm closers can only be mounted as a Push Side parallel ar...:
Are there parts available for the obsolete 330 series door closer?
Resolution:
The 330 closer and parts were discontinued in early 2009. LCN does not have any parts available for the 330 series closer. The LCN 3030 Series would be the comparable closer replacement to the...:
On which closer is the fusible link arm available?
Resolution:
The Fusible Link arm is available with the 4010, 4020 and 4110 series closers. They all use the same Fusible Link arm. The UL Listing number is for the Fusible Link arms is R1943.The 4010 Series ca...:
Will CX re-arm if door is held open?
Resolution:
If a door position switch (DPS) is connected across the green and white wires of the old CX (green and red of new CX) the CX would go into alarm if the door is held open when it attempts to rearm.&...:
What are Overhead Concealed door closer?
Resolution:
Overhead Concealed door closers are used to provide a more aesthetic look to the opening. Concealed in either the frame or the door Offer the ability to be adjusted to maintain...:
Which closer is the heaviest duty?
Resolution:
The 4010, 4020, 4110, and 4040/4040XP are heavy duty closers.:
DOOR FACE
Resolution:
A-Panel, B-Panel, Push side, Pull side, hinge side, stop side:
Does the Von Duprin CX 98/9975 allow lever entry from the pull side without sounding the alarm?
Resolution:
As long as there is no door position switch wired to the CX the outside trim will work as it would on a standard 98/9975 device. :
SWING FREE ARM
Resolution:
SF arm, designed to allow free movement of the door without disengaging the holding mechanism:
What is the difference between the 4040, 4010, 4020, and 4110 series closers?
Resolution:
4040XP Series (4040 DEL) is a universal closer. *(see note) Non Handed closer. Can be mounted on a RH or LH door. 4041XP - Adjustable size 1 to 6. Can mount push side or pull side of the doo...:
What is the difference between Panic Hardware and Fire Exit Hardware?
Resolution:
The most obvious difference (in the device) is the lack of mechanical dogging on a Fire Rated Device. There are some internal parts that may be different and the method it is secured to the d...:
What would cause a Senior Swing to open too far?
Resolution:
The Senior Swing operator is designed to power open the door to 90°. The built in dead stop (in the gearbox) prevents it from opening any further. If the Senior Swing operator is opening to far (pa...:
How do you install a Senior Swing 9540 on one leaf of a double door?
Resolution:
Surface Mounting - A 9542 HDR2 (Double Door Header) and a 9540-18 mounting plate can be used on the active leaf. A manual closer with a PA (parallel arm) can then be installed on the inactive leaf....:
What are Insulclad doors?
Resolution:
Insulclad® entrance door systems are commercial aluminum entrance systems manufactured by Alcoa/Kawneer. Door panels include a layer (1/4" or 1/2" thick) of material added to the push side of ...:
Is the 4040 HEDA arm handed?
Resolution:
The 4041/4040XP HEDA arm is handed because of the hold open feature. The regular EDA arm is not handed.:
Can you replace a regular arm with a hold open with out moving the door closer?
Resolution:
Yes, as long as you stay with the like style arm. Example: replace an RW/PA with HW/PA, replace an EDA with HEDA, or replace a CUSH with HCUSH.:
Can a 1460 EDA open to 180°?
Resolution:
The standard 1460 EDA arm is not long enough to allow the door to open 180°.ST-2430 is a special 1460 EDA arm that will allow the door to open 180°.:
Why does the arm of my 4110 EDA touch the door when it is closed?
Resolution:
If the closer arm is touching the door, it is because the arm or the closer body is not templated correctly. Confirm dimensions are taken from the proper location and make corrections if needed. :
DOOR PULL
Resolution:
hardware; pull handle, push plates:
Which of the Pneumatic operators uses the same cylinder?
Resolution:
The 4840 and the 4810 are they only cylinders that can be interchanged, they use the same cylinder for their individual applications.:
Does Von Duprin offer any pulls that through bolt to the Guard-X device?
Resolution:
Von Duprin does not offer any lever trim or pulls that through bolt to the Guard X device. Ives has the 8102-6 and 8105-6 pulls that can be lined up with the mounting screws of the exit device b...:
How do you install the arms on a 9100 Series Benchmark operator?
Resolution:
The installation of the arms with the Benchmark and Falcon Swing Door Operator is similar to the Sr. Swing Series . The arms are installed with the main activation input shorted, the gearbox at the...:
What would cause an EL device to pull and release?
Resolution:
If your Von Duprin EL (solenoid) device pulls and releases quickly instead of holding the latch retracted, please check all of the items below.In most cases, one or more of these solutions will r...:
What special template (ST) is used with a 4110 closer and GJ90 series?
Resolution:
ST-2730 is used with a 4110EDA closer and GJ901-904 overhead stop.This can only be used with GJ901-904.If a drop plate is required, a 4010-18 drop plate would be used (A 4110-18 drop plate can not ...:
Where is the RA closer reinforcement located on a frame for a Regular Arm Closer?
Resolution:
Optional closer reinforcements are located at 3" from hinge jamb to the beginning of the reinforcement plate. This applies to Regular Arm, Parallel Arm, Top Jamb. Regular Arm (RA) closer reinfor...:
How do I set the hold open on my 4040 closer?
Resolution:
The hold open position on a "REG" or "EDA" hold open arm is set with the door to a few degrees shy of the desired hold open point. To properly set, open the door 5° less then the desired hold open...:
What do I need to do to make my 4041 Reg/PA a hold open arm?
Resolution:
When placing an order for a 4041/4040XP Rw/PA with hold open, it would be ordered as a 4041 /4040XP Hw/PA. For an existing Rw/PA requiring the addition of a hold open function, a hold open arm woul...:
What are Hold Open Closers & Magnets?
Resolution:
Hold Open Closers & Magnets (Fire/Life safety products) provide a wide range of solutions. Single or multi-point hold open closers Utilize an electromechanical closer. Hold the door o...:
Are astragals required on fire doors?
Resolution:
Astragals are required on: 3 hour fire rated pairs: Double doors - swinging in the same direction Double Egress - swinging in opposite directions Fire rated Dutch Doors Fire rated 1 3/4" t...:
What drop plate is used with a 4040 Rw/PA?
Resolution:
The 4040 Rw/PA can be mounted 3 different ways. The 4040-18 drop plate is used for the regular pull side mount. The 4040-18TJ drop plate is used for the top jamb push side mount. The 4040-18P...:
Why is the ND lever hard to push on?
Resolution:
ND locks shipping on or after January 30, 2017 no longer require the use of the soft durometer spacer. Lever installation on the redesigned ND locks should not be difficult.:
Can a 24-R, 24-V, 25-R, or 25-V device use just a cylinder on the pull side for NL-OP function?
Resolution:
This is possible. A rim cylinder with cylinder anchor plate is used (anchor plate provided with rim cylinder package). No other special components are required. Order device as NL-OP.&...:
Can a 9500 series operator on the push side be used with Cam lift hinges?
Resolution:
The Senior Swing will work with Cam Lift Hinges as a PUSH SIDE MOUNT 9542/9553/9563 only. Maximum 3/4" lift. Maximum 15 pounds force to push door up the Cam Lift Hinge. Cam Lift Hinges WILL NO...:
Can I use a Glynn Johnson 410 with a 4040 regular (pull side) mount?
Resolution:
ST-1630 is required when mounting a 4041 or 4040XP door closer regular (pull/hinge) side with a concealed GJ100 or GJ410 series over head stop.This ST also REQUIRES the use of a 4040-18TJ drop plat...:
What is the model number for the Ives door edge pull?
Resolution:
The sliding door edge pull is part number 230.:
Are the Falcon SC Series door closers fire rated?
Resolution:
Yes, the Falcon SC Series closers have a UL listing.:
Can a 4040XPT DE be used with a 4" reveal on the pull side?
Resolution:
The LCN 4040XPT with a reveal deeper than 1/8" on the pull side of the opening requires a Double Egress (DE) arm.DE arms are handed arms and cannot have handing changed in field.ST3073 Standard 404...:
What is the purpose of a Swing Free arm on a 4310ME?
Resolution:
The (SF) "Swing Free" arm allows the door to be put into hold open position, but then repositioned (swing free) to any other degree of opening without taking the closer out of the hold open mode....:
Does a SEH require a door closer?
Resolution:
The SEH is an "electronic holder" (ONLY) that is used to hold open a Fire Rated opening. It requires a door closer to be mounted on the opposite side. It is normally used on an existing opening wit...:
Does the old style 4030 have the same templating as the new style 4031?
Resolution:
The old 4030 series was: Handed Mounted regular arm hinge side. Had sized springs, were not adjustable. The 4033 is an obsolete closer. If required, handing can be verified by looking at ...:
What are the minimum header lengths for a Senior Swing?
Resolution:
The minimum header lengths for a Senior Swing with standard Spindle centers are:Concealed 2810 Series:2811 single door (offset pivot or butt hinge) -- 33".2811 single door with stop (cent...:
Is there a heavy duty arm available for the 4040 mounted pull side?
Resolution:
ST2795 allows the the 4040 to be mounted pull side with a solid (heavy duty) arm.:
Can you mount a 4011 as a parallel arm like the 4111?
Resolution:
The 4011 can only mount on the Pull Side of the door and the 4111 can only mount on the Push Side of the door. Differences - The 4011 and the 4111 cylinders are different and the pinion shafts are...:
What is the difference between the 2030 and 5030 closer?
Resolution:
2030 and 5030 are both overhead concealed closers. Catalog information can be found here. The 2030 uses a concealed, in the door, track, and a concealed one piece arm. The 5030 use...:
Why would a Falcon 8200 operator have an inconsistent opening?
Resolution:
An inconsistent opening is normally caused by the arm not being installed correctly. The arm must be installed while the operator gearbox is in the full open position, and the door at 90° open posi...:
Can you install a 4041 pull side at 180 degrees?
Resolution:
The maximum opening is 120° with the 4041/4041XP standard templating on the pull side of the door.For pull side mount, you can achieve 160° of door opening with ST-2359, which consists of...:
Is there a retrofit closer available for the obsolete 303 OHC closer?
Resolution:
The LCN direct retrofit for the Obsolete 303 OHC closer was the 330 series, it was discontinued in 2009. The 3030 closer door closer body can be used as a replacement cylinder. :
What parts are needed to change a Senior Swing 9530 to a 9540 operator?
Resolution:
To convert a 9530 to an 9540 you need to purchase the 9540-3077 REG push arm assembly for reveals up to 10” or 9540-3077L long arm for reveals from 10” to 20”.To convert a 9540 ...:
PUSH SIDE
Resolution:
Face of door on stop side of frame:
Chexit goes into alarm with fast flashing LED and not locking after rearm time.
Resolution:
Chexit devices shipped prior to 8-24-2015 with solenoid driven: Chexit device has a RX switch with a connector that needs to be connected to the Chexit module otherwise the alarm will sound af...:
What would cause my door closer to try and open the door instead of closing it?
Resolution:
For a door closer that tries to open the door instead of closing it:The closer body could be mounted backwards on the door - check instructions for proper closer orientation.It could be the wrong h...:
What backsets are Hospital latches available?
Resolution:
Hospital latch available backsets: 2-3/4", 3-3/4", 5" or 7":
What are Pneumatic Automatic Operators?
Resolution:
Pneumatic Automatic Operators are used in areas where electrically operated devices are not convenient or permitted. Consists of a modified, heavy-duty door closer for manual oper...:
What is the definition of double egress?
Resolution:
Double Egress Opening: A pair of swinging doors, each leaf which swings in the opposite direction of the other. DOORS: A pair of doors swinging in opposite directions without a vertical mullion....:
Why does the Schlage button light up “Green” when I open the door?
Resolution:
When unlocking the CO200 door by mechanical key override, the green led will be continuously ON until the key is released. This will occur after firmware CO.A.6 (or later) has been installed int...:
What are the dimensions for mounting a 1261 on the pull side of the door
Resolution:
http://lcnclosers.com/pdfs:
Which closer should I use for a "High Wind" condition?
Resolution:
A 4110 with AVB (advance variable back check) would be recommended. Using a SCUSH (Spring Cush) arm will also help minimize shock to all door hardware.:
Can a 4040 open to 180°?
Resolution:
The 4040/4040XP closer mountings have the following maximum opening degree templating: The 4040/4040XP PA "Regular Arm" mount will allow for 180° max. opening. The 4040/4040...:
How do you remove an AL lock from a door?
Resolution:
AL-Series and discontinued D Lever-Series locks use castle nuts to hold the chassis to the spring cages and to keep the chassis positioned in the door. This causes confusion at times when the lock ...:
What are Electro-hydraulic Automatic Operators?
Resolution:
Electro-hydraulic Automatic Operators are: Designed for manual opening applications where there is occasional need for automating the door to meet ADA requirements. Electrically powere...:
Can I mount an LCN Cush closer with an GJ overhead stop?
Resolution:
It would be unnecessary to use the CNS/Cush arm and the Glynn Johnson overhead devices in the same application, both mechanisms stop the door.:
Can a 4041 EDA be mounted top jamb?
Resolution:
The 40401/4040XP closer with optional EDA arm has to be mounted parallel arm on the push side of the door.:
What LCN closer has the strongest closing force?
Resolution:
The size 6 handed closers will have the most (strongest) closing force. The 4016 (pull side), the 4026 (top jamb push side) or the 4116 (push side parallel arm) have the highest closing force.:
What causes the top rod case to pull away from or strip out of the face of a steel door?
Resolution:
Hardware falling off a door is caused by one or all of the following issues: Field abuse Improper internal reinforcements in the door Improper field preparation The top or bottom rod case can...:
What is the narrowest door a 4040 pull side will mount on?
Resolution:
14" door leaf is the narrowest with standard template.:
Can a 4010 be mounted with swing clear hinges?
Resolution:
Locate closer and arm from the centerline of the swing clear hinge pin.:
Why does my Chexit device open without sounding the alarm?
Resolution:
:
What special template (ST) is used with a 4040XP with a non-adjustable (solid) regular arm for pull side mounting?
Resolution:
Special Template ST-2795 is used to mount a non-adjustable (solid) regular arm for pull side mounting. :
How do you change a 9130 Benchmark to a 9140 Benchmark?
Resolution:
The only difference between the 9130 and 9140 Benchmark operators are the arms.To convert a Benchmark 9130 (pull) to a 9140 (push), order a 9140-3077 push arm assembly for revea...:
What side of the door is the 4040SE mounted?
Resolution:
The 4040SE is non handed and can be mounted on the push or pull side of the door.Installation Instructions :
Can a Cam Lift hinge be used with LCN closers?
Resolution:
Cam Lift hinges can only be used with LCN door closers that have a "Regular" or "Reg hold Open" style arm. Manual Closers:Maximum lift dimension is 3/4".Can not be use (H)EDA, CUSH, or T...:
Is there anything special about 2" thick doors for the 98/9947 devices?
Resolution:
Standard 98/9947 works on 1 3/4"- 2 1/4" thick door.:
Can you manually pull a 4040SE out of hold open?
Resolution:
The holding force on an SE/ME Series door closer is approximately 35 lbs. and they can be manually pulled out of hold open with approximately 35 lbs of force. :
Can a pull side mounted 1460 open 180°
Resolution:
A 1260 Pull Side can be mounted standard template for 180°, frame and trim permitting.:
Why would a 4600 not open a full 90 degrees?
Resolution:
A 4600 (4630/4640) not opening to a full 90 degrees could be caused by a couple things: The Opening Force could be set too low. Try increasing the opening force adjustment on the controller a 1/...: