Yes, hospital stops are available on fire rated frames. Maximum approval = 3 hour Maximum sizes:  singles up to 4'0" x 8'0" pairs up to 8'0" x 8'0" Maximum hospital stop height 6" from bot...
Monorail cutouts are typically the upper corner of door. Channels are cut to size welded into door held flush to cutout. We do not supply any covers or plates to finish.
The size monorail cutout is 8" wide x 24" high
Monorail cutouts are only available for non fire rated applications.
The following size limitations per frame unit, are in enforced for welded elevation frames shipped from the factory. These limitations are in place due to the physical size of shipping tr...
The following hinges are available on Paladin series doors and frames: Butt hinges -  4 1/2", 5" or 6" ball bearing type either standard or heavy duty Continuous hinges - full mortise...
EPT power transfer preparations are not available on the Paladin PW14-Series door and FP14-Series frame. Electrified hinges are available on the Paladin PW14-Series door a...
Reveal should not exceed: 6" for the REGULAR ARM 9 3/4" for the LONG ARM
The use of Panic Hardware and/or Fire Exit Hardware is required by the International Building Code (IBC) and NFPA 101 – The Life Safety Code, depending on which code and which edition of the code i...
Hinge Spacing: All 4 1/2" and 5" butt hinge spacing 1. Opening heights 3'0" through 4'11 15/16" (one pair butt hinges) from under head CL 9 3/4" (top of door 9 5/8") from bottom of frame ...
Hinge Backset: On the frame = 5/16" On the door = 1/4"
Lock Spacing: All standard bored locks ANSI 115.2 (161, 61L type), for mortise lock ANSI 115.1 (86 type) all locations must be altered 3/8" lower, and standard strike (ASA type). 1. Opening ...
Since most wire transfer devices such as an EPT or electric hinges cannot provide large gauge wires, we take the small gauge wire into account when determining the overall wire size for the device....
The 4000T Series closers have a maximum opening of 90°.
Glass lights are available in fire rated T-Series doors: Limited to one (1) light per door leaf with a maximum of 100 square inches of exposed glass. This applies to all hourly ratings a...
Templates for 224HD TW8 continuous hinges are  829431-00 for 83" & 85", 829433-00 for 95" & 829435-00 for 120" tall doors. Templates for 112HD TW8 continuous hinges are 829430-00 for 83" & 85", 82...
Pull Side Mount: The 4040SEL X ST-2966 is required for pull side mounting with swing clear hinges. ST-2966 template
Push Side Mount: Take the dimensions for the closer and track from centerline of swing clear hinge pin for the push side mount.
Maximum reveal for a 4041 regular arm is 2-9/16". The reveal for a 4041 long arm is from 2-9/16" to 4-13/16". The reveal for a 4041 extra long arm (ELR) is from 4-13/16" to 8". ST-2523 is a sp...
Steelcraft Paladin PW-Series doors and FP-Series frames meet FEMA Tornado Resistant requirements and have been designed and tested to meet the requirements of FEMA 361 guidelines and ANSI ICC500. ...
Fire labels (UL, ITS/WHI or FM) are located as follows: Butt Hinges and Pivots: On the doors the fire label is located on the hinge edge between the top and 2nd hinge preparation. On the fram...
Max. reveal for a 4642: 4640 Regular arm -- 4.5" 4640 Long arm -- 8" 4640 x ST-3088 ( custom made - extra long rod) -- 8" to 11" No special mounting instructions required, just standard templ...
Consider the Soss hinge like a butt hinge to determine the size of overhead that is needed.  For templating use the same mounting group as a 4" wide butt hinge and the appropriate door thickness.
The SL-Series door is a square edge non-handed door. A Hinge Filler  (also referred to as Hinge Spacer) is the small removable trim part located on the door between hinge leaf and hinge reinforcem...
Maximum glass light size for a 90 minute (1 1/2 hour) door depends on the type of glass being installed. Wire glass = 100 square inches is max exposed glass when wire glass is used. Note - ma...
Locate closer and arm from the centerline of the swing clear hinge pin.
Dutch doors are available as Fire Rated door assemblies and have similar component requirements as a single leaf fire door. Exceptions are as follows: The Dutch Door assembly must have a lock...
The regulation valves are designed to adjust the flow the hydraulic fluid in the closer which regulates the door closing speed through various phases of the closing cycle. The regulation valves h...
Maximum nominal (overall) single door sizes are as follows: L-Series (Laminated Door) 20 Gage = 3’ 0” wide X  8’ 0” high 18 Gage = 4’ 0” wide X 10’ 0” high 16 Gage = 4’ 0” wide X 10...
Hinge manufacturers do not require or recommend that doors should be reinforced for continuous hinges. Steelcraft does not reinforce for continuous hinges unless it is specified on the customers' P...
“Cache Mode” is an AD-Series feature which, accumulates and stores valid credentials that have recently been granted access by the Access Panel or head-in system. This recently granted access histo...
The number of bits selected for "Card Bit Format" on an AD400 or AD300 must be equal too or larger than the bits on the cards in use. Setting this number correctly enables the cache mode collectio...
The AD300 and AD400 devices do not store audits during cache mode.  Audit "Date and Time" information and the saving of audit information is an Access Control Panel function, and during cache mode ...
An AD400 granting credentials access in “cache mode” will blink the Schlage with the normal green LED, followed by a brief red Schlage LED flash, indicating no RF communication and access was grant...
When installing the arm; the gearbox shaft and door must be at the (+90°) full open position. The following step are used to install the Senior Swing (STD) pull arm. Install the header using app...
Doors require special downsizing for continuous hinges. The amount of downsizing depends on the hinge specified (manufacturer and type) and the hinge application (Full Mortise versus Full Surface v...
The 8402 kick plate is "A" label for metal doors and "B" for wood doors.
Steelcraft have tested different types of doors and frame assemblies using Zero International gasket seals for the various STC ratings. Tests are in accordance to ASTM...
Frames can be installed either KD (knock down) or welded to receive the STC rating.
Steelcraft borrowed light frames are not listed/tested. Check with the glass manufacture if they are listed and with what type of framing used.
Sound seals are required. Zero International Gasket Notes: Perimeter Seals – Zero #475 applies to the stop of the head and jambs. Door bottom – Zero #367, surface applied. Threshold ...
Maximum hourly rating for a transom and side light or panel frame is 1 1/2 hour (90 minutes). In masonry wall application the maximum is 13'6" x 12'2" In stud wall application the maximum is 13...
Push Side Surface Mount Senior Swing can be used with swing clear hinges, standard templating. Pull Side Surface Mount Senior Swing cannot be used, the pull arm will hit the back of door at approxi...
To correctly answer this question, we need to know how much more force is required to get the door closed. They could try turning the Rod & Shoe over (short side of shoe towards the hinge), or they...
Maximum UL Fire Rated door sizes are as follows: A-Series: 4' 0" X 8' 0" single door 8' 0" X 8' 0” double door or pairs B-Series 4' 0" X 10' 0" single door 8' 0" X 10' 0” double doo...
There is no fire rating for butt hinges, but NFPA 80 says to use steel material and ball bearing hinges for fire rated openings.
The minimum top and bottom butt hinge locations are as follows: To the hinge centerline: 4 1/2" and 5" hinges = 5 3/8" is the minimum location from top of door to centerline of the first hi...
The 4040/4040XP closer mountings have the following maximum opening degree templating: The 4040/4040XP PA "Regular Arm" mount will allow for 180° max. opening. The 4040/4040...
The Senior Swing will work with Cam Lift Hinges as a PUSH SIDE MOUNT 9542/9553/9563 only. Maximum 3/4" lift. Maximum 15 pounds force to push door up the Cam Lift Hinge. Cam Lift Hinges WILL NO...
Pocket pivot hinges are mainly used in cross corridor applications where clear opening width is a factor. For frames, pocket pivot hinges are a special hinge options which must be spe...
A Kerfed Frame is a frame that is formed with an optional integral pocket or recess in the area of the stop to receive gasket, seals or weather stripping. Kerfed frames are available as an&n...
All the 2030 series closer have a fixed spring sizes. Example -- a 2031 has a size 1 spring,  a 2302 has a size 2 spring, 2033/2034/2035 etc. All the 2030 series closer are shipped at the weakest s...
Yes, Steelcraft doors we are approved up to 48" in height or not to exceed a total 2304 square inches per face. Protective plates are usually flat sheets of metal or plastic applied to one or both...
The SEH is an "electronic holder" (ONLY) that is used to hold open a Fire Rated opening. It requires a door closer to be mounted on the opposite side. It is normally used on an existing opening wit...
Fire Rated three (3) frames are available in the following maximum door opening sizes: F and FN-Series frame: 4' 0" X 10' 0" single door opening 8' 0" X 10' 0” double door opening MU-Ser...
Swing clear hinges are available with TW (through wire).
Please see  Glynn-Johnson and Ives Care and Maintenance instructionsOnce the link opens there will be an attachment to "click" on.
Power Boost is a positive latching feature that increases the latch force, to over come building stack pressure or door weather stripping, etc, if the door stops before coming completely closed. T...
Steelcraft locates all butt hinges from the top of the door to the centerline of each hinge as standard practice: Locating hinges to the center line of the hinge keeps all hinge locations the sa...
Recommend at least a 4 wire hinge and double up the wires for EL application.
All hardware options (available on standard door) are available on GrainTech® doors. Available hardware are covered in the Steelcraft Price Manual. GrainTech® doors can be prepped for the Von Dupr...
Maximum Dutch Door sizes are: Non Labeled = 4'0" wide X 8'0" High Labeled = 4'0" wide X 7'2" High Special sized Dutch Doors are available: Special size top and/or bottom leaves are availabl...
ST-1630 is required when mounting a 4041 or 4040XP door closer regular (pull/hinge) side with a concealed GJ100 or GJ410 series over head stop.
The 4110 Cush closer can be templated for 85°, 90°, 100°, and 110° maximum as standard templates. The 4110 if ordered by ST-3220 will allow templating to 135°
On fire rated transom and/or sidelight frames and fire rated window frames, Steelcraft labeling procedures only control the O/A width and/or height of the frames based on wall condition. The amount...
The Security Stud and TW4/8 (through wire) options are in the same location on a hinge and cannot be ordered together.
Not specifically for lead lined doors.  But the standard hinges should work and not hit the lead lining in the door.  Since standard lead layers vary, check with door manufacturer an...
An EPT can be used with a Cam Lift Hinge: Maximum hinge lift dimension = 1/2".  The EPT must be installed correctly with the tube at the top on the door side and the tube at bottom on...
A UL 20 minute fire rating is the maximum fire rating for a Full Glass (FG) door design. A14-Series door construction: Max fire rating is 20 minute. UL label only FG must use Over-Lapping Stee...
Cutout depends on the size of 224 hinge.  See 112HD/224HD-EPT template.  112HD/224HD continuous hinge  Center line of EPT to top of the door  83 inches  30 inches  85 inches  32 inc...
Communicating Frames are hollow metal frame fabricated such that a door is installed in each rabbet of a double rabbeted frame (2 doors total) to facilitate dual access and control of the opening, ...
ASTM E-119 is a test standard for walls, partitions and floor or roof systems: This test standard is also used for ceramic type glasses when used as window wall and/or borrowed light frames. ...
GrainTech® is available with very broad fire ratings. The option of GrainTech® does not affect the fire rating of the door. Fire ratings depend on the door series, hardware and applications. ...
Use mounting group 2 per templates below when a GJ 100 and 410 series overheads are used with continues hinges. 100 series overhead instructions 410 series overhead instructions
The 9542, 9553, 9563 surface mounted Senior Swing with a regular arm, mounted on the push side of the door, can handle a reveal from 1 1/8" up to 10". The 9542, 9553, 9563 surface mounted Senior S...
DW-Series Fire Rated Borrowed Lights are available in the following sizes: 60 minute (1 hour) rating = 2721 square inches of visible glass. maximum frame rabbet to rabbet dimensions = 78 1/4...
From head to centerline of each hinge (4 1/2" or 5") is 9 3/4", 39 3/64", 68 11/32" & 97 41/64".
The hinge spacing on a 9'0" frame opening height is 29 19/64".
From Head to top of each 4 1/2" hinge is 7 1/2", 36 51/64", 66 3/32" & 95 25/64". From Head to top of each 5" hinge is 7 1/4", 36 35/64", 65 27/32" & 95 9/64".
Butt hinges can be used on  doors up to 4' wide and 200 pounds.  There is no maximum door height, just need to add a hinge for every 30" or part there of over 7'.
The American National Standards Institute (ANSI) and Builders Hardware Manufacturers Association (BHMA) have developed durability, strength and performance standards for every type of door hardware...
The maximum recommended door weight for LCN closers is 225 lbs.
The location to the top of hinge will vary depending on hinge size used. 6'8" Frame with 1 1/2 pair of hinges (top to top): For 4 1/2" hinges from the head to top of each hinge is 7 1/2", 37 7...
A fire rated door for 3 hours can have one glass light maximum: 100 square inches and must have an approved glass (Firelite type) Max glass size cannot exceed 12" in width or 33" in height. Wi...
The Senior Swing operator is designed to power open the door to 90°. The built in dead stop (in the gearbox) prevents it from opening any further. If the Senior Swing operator is opening to far (pa...
Non fire rated doors can be furnished with a maximum 3" diameter hole for viewer preparations. Fire rated doors have a 3/4" maximum holes size unless otherwise listed by UL or ITS/WHI. Viewers mus...
See attached templates.  5BB1HW Swing Clear Hinges
The PIB300/PIB301 should be located as close as possible to the Access Control Panel.  Do not exceed 500 feet.
Wiring distance from the PIB300/301 to the AD300/301 locksets may be up to 1000 feet (18AWG) for Power and up to 4000 feet (24AWG) for the RS485 data lines.
See the User Guide instructions in the links below
ITS/WHI Fire Rated three (3) frames are available in the following maximum door opening sizes: F and FN-Series: 4' 0" X 10' 0" single door 8' 0" X 10' 0” double door or pairs MU-Series: ...
No, the geometry of a swing clear hinge prevents the coordinator from working correctly.  The bar style coordinator will not hold the active door open far enough for the inactive door to clear the ...
Cam Lift hinges can only be used with LCN door closers that have a "Regular" style arm.     Manual Closers: Maximum lift dimension is 3/4". Can not be use EDA, CUSH, or Track Arm door closers...
Standard Schlage rim cylinders will fit a total thickness of door and projecting trim of 3 inches, this includes a minimum of 3/8" of engagement of the tailpiece into the exit device.  See ima...
For total thickness measurements larger than 3 inches see the special cylinder offerings in Pricebook.  Specify the part number and include the total thickness.  We do not offer the ...
A Double Egress frame is a double door frame prepared to receive two single-acting doors swinging in opposite directions (both doors are) the same hand. These openings are installed in cross corrid...
Glass Light is a preparation in a door for view window, vision and/or glazing including glass stop and glazing bead and may also be refereed to as a lite. Doors are available with a wide variety o...
1 3/4" is the standard door thickness. Steelcraft only makes a nominal 1 3/4" thick door. A 1 3/8" was made for light duty commercial applications but that product was discontinued in 1999.
The standard gap between a pair of doors will be 3/16" when used with a Steelcraft  "Z" astragal. If a wide inactive leaf is requested (no astragal) the gap between the doors will be...
The pneumatic operators are designed to function with an input air pressure to the 7901/7902 Series control box of 80 (min) 100 (max) PSI, and an output pressure of 60 to 80 PSI to the pneumatic (2...
EPT can be used on following hinges: Degree of the opening Hinge type Door thickness 0-180 degree Up to 5" butt hinges 1 3/4" 0-180 degree Up to 3/4" offset pivots 1 3/4" 0-130 degree 5 1/2"...
See related solution: Can an EPT be used with Cam Lift Hinges?
"5, 10 and equal" Hinge Spacing: The industry terminology which usually refers to the Custom (NAAMM/HMMA) Door hinge locations. This location dictates: Top Hinge - located 5" from the underside ...
No, LCN does not have an electronic hold open closer (SE/ME Series) that will provide a solid 180° hold open position. The 3130SE has an adjustable hold open position from 85° to 110° maximum. ...
Steelcraft uses a 7 gage hinge reinforcement for 4 1/2" and 5" butt hinges as standard on all frame series. The hinge reinforcement size for either 4 1/2" or 5" hinges (standard or heavy duty hing...
The 455 can be mounted on a 48" wide door, but we cannot guarantee that it will withstand the forces involved.  Recommend using 906 instead.
The maximum door width that pivots have been tested is a 4' wide door.  Any door greater than 4' would shorten the life of the pivots. There is no maximum door height, for offset pivots the ru...
The rough opening dimensions are the same for either Welded (SUA) or Knock Down (KD) frames For F, FN, FE, DE, MU three sided frames and four sided borrowed light frames: New masonry Walls: N...
 For DW, K three sided frames and four sided borrowed light frames: Three sided frame = door opening width (order size) plus 1 1/2" minimum to 2" maximum and the door opening height ...
Applies to L9090EL/EU, L9091EL/EU, L9092EL/EU, L9093EL/EU, L9094EL/EU, L9095EL/EUOvervoltage will cause the lock to shut down for approximately 5 minutes to allow the circu...
FM Global is an independent underwriting agency with listing, in-plant inspection, and labeling capabilities. FM fire rated doors and frames are available, however there are a minimal amount ...
Using Soss hinges with closers can require special device and preparation locations. If you have questions on specific closer applications, please e-mail your request (including a description ...
The 2030 Instructions included with the unit has templates for mounting with standard butt hinges, center pivots, and offset pivots.
 Cam Lift Hinges are specially designed hinges used mainly on acoustical door assemblies. The Cam Lift Hinge lifts the door during its travel and seats the door bottom for a pos...
Model 69 the part number is 09-310Model 70 & 73, the part number is WSPART.1075
Product Ordered after 7/10/2012 - Product identified by label on QEL motor You no longer need to use the 900-2Q option board (no longer available) with the PS900 power supplies to ...
Product Ordered before 7/10/2012 - Product identified by no label on QEL motor. You must use the 900-2Q option board with the PS900 power supplies to operate the QEL devices.  The attached ta...
Steelcraft follows the industry standards for hinge reinforcement and preparation for both door and frame. Unless otherwise specified all products prepared for butt hinges will have mounting holes ...
The maximum reveal for an 8200 Falcon Operator is: 8230 (pull side) -- 1/8" 8240 (push side) -- 6"  The Benchmark long rod and shoe (9140-79LR) can be use with the Falcon 8242 for reveal from ...
Steelcraft offer a 12 gage F-Series frame. Basic product offering: Door opening size: Single Door = 4´-0" x 8´-0" Double Door = 8´-0" x 8´-0" Double rabbet only. Single rabbet is not ...
The AL series lock fits up to 1 7/8” door thickness out of box.
ITS/WHI is "Warnoch Hersey". ITS/WHI is the formal designation for Intertek Testing Services / Warnock Hersey. ITS/WHI is an independent agency with testing, listing, in-plant inspection, and label...
Yes, the spring torque on 3SP1 butt hinge is adjustable.  See instructions at this link:https://static-or01.inbenta.com/fc7332911aa38d5387ffdef79e8605c6ecdc727ece31acf5bc8e26dcac5d29e4/Iv...
Please visit the Schlage Residential website (FAQ / Knowledge Center) for all product and Customer Care information.Click on the following to link directly to the Residential Product...
The minimum door thickness that the AD or CO series lock will mount on is 1 3/8".  Be advised that this will require additional spacers to be ordered separately to allow the lock to mount...
Hinge backset is the dimension from the leading edge of the hinge to either the stop on the frame or to the stop face (push side) of the door. For operating clearance, the hinge backset on the d...
The maximum 925 tubing run length from the Control Box to the Door Closer is:  7980 Series Control Boxes --- 50 "Linear" feet from Control Box to Door Closer.  7900/7940 Series Control Boxes --...
Maximum glass light sizes for 3 hour fire doors is as follows: Wire glass - not approved for use in 3 hour fire doors. Ceramic glass: UL & ITS/WH allow one (1) light with 100 square inc...
The 609 finish is not available with Ives butt hinges.
The maximum width door the Steelcraft can make is 4' 0"