keyed lock handle removal no key for lock

RELATED FAQS

Question
Answer
After rotating  the key to unlock the lock, you must return the key to its normal position to remove it. 
The lever may be missing the slot feature for the core locking lug.  Verify slot is in place.
This is usually caused because the wrong tailpiece is being used on non-IC cylinders or the incorrect driver for IC options. Use the below descriptions to identify which they need.NON-IC: There are...
To disassemble an X lock, remove the inside knob and unscrew the inside collar and rose.  The X lock spanner wrench (012172-000-30) can be used to depress the knob catch as well as tighten/loo...
First, take wire in shape of 9 and pop off interior door knob or lever. Second, take a flat nose screwdriver and pop off the decorative trim. Lastly, you will see the screws and be able to remove l...
To remove the knob:  Turn key 45 degrees clockwise Push in catch push pin and pull off knob  
*The older wafer style locks did not use a knob catch.  The chassis must be disassembled before the knob can be removed because it uses the wafer lock chassis spindle.
We do not offer a double cylinder handle in our residential hardware, you can find that type of product in our commercial line. Some examples are the ND60PD, ND66PD, or the ND75PD. For assistance w...
T381 Classroom Security Lock is not a "true" classroom security / Intruder lock function. The T381 is classified as a ANSI/BHMA F88 function: Defined as Grade 1, Apartment, Exit or Public Toil...
The Schlage full size interchangeable core (FSIC) prepped B560F, B561F, and B563F deadbolts all require a UL fire cup (R) in order to be UL listed.  This fire cup is s...
The 98/99 rim and vertical rod exit devices are shipped with NL drive screw to function as a Night Latch. To convert the device to Class Room, remove the NL Drive Screw on 98/99 center case ass...
The keycam may have failed, example here, the latest design keycam can be easily identified as the colored changed to black. Replace either the keycam or chassis as needed...
 This could also happen if the tailpiece isn't installed in a KIL, FSIC, or SFIC cylinder.  The FSIC driver also could have come loose from the core in the spindle.
When you want to periodically disable and block access to a certain room in a building or an entrance door, that’s when you would need to use a Lockout Cylinder. See full document.
e.Primus was an electronic lock system that used iButton credentials to unlock a door.  Product was discontinued in July of 2002 with parts were available only for a short time.  Product support fo...
Using the mechanical key will report in the audit trail as a “forced door” alert.
Two change or user keys are supplied with each lock.
The KR4023 mullion requires a 1-1/4" mortise cylinder with straight cam. This is stated in box 7 on the first page of the KR4023 mullion instructions.
With the new FW package 2.19.0; AD300 FW 2.17.0 and AD400 FW 2.17.0 (released 09/23/2011) the firmware looks for a motor clutch switch change after a motor move command. If there is no motor clutch...
If the triangles in the spring cage spindle are not aligned properly the motor will not move enough to change the clutch switch. Is is very likely with a lock on the bench; but a properly install...
When the new firmware moves the motor three times without seeing the clutch switch change it reports to the SUS diagnostics that the motor is stalled. Aligning the triangles will let the motor move...
If the lock is mounted on the door, it is necessary to adjust the mortis/cylinder tightness and spring cage tailpiece alignments, making sure there is no binding or stopping of the spring...
Just align the triangles per the installation instructions to allow full motor movement.   - This will eliminate the SUS motor STALL report. - This will eliminate the three ...
All lock cylinders on a specific project are operable by a special "project key".  Duplicates of this key may be assigned by the building contractor to workmen and subcontractors as required...
Hotel guest lock - Latch bolt operated by key from outside or by operating inside knob/lever. Outside knob/lever is always inoperative. Dead bolt projected by turn from inside and all keys except e...
Dormitory lock - Latch bolt by knob/lever inside and key outside. Inside knob/lever free. Outside knob/lever rigid. Deadbolt by key outside or T-turn inside. Rotating inside knob/lever retracts bot...
Storeroom lock - Latch bolt operated by key from outside or by operating inside knob/lever. Outside knob/lever is always inoperative. Auxiliary dead latch.
Hotel/motel lock - Deadbolt thrown or retracted by emergency master key in upper cylinder from outside or thumbturn inside. Deadlatch retracted by key in outside knob, except when the lock is in ...
Dormitory lock—Deadlocking latch bolt by knobs except when locked by push button in inside knob. Key in outside knob locks or unlocks outside knob and releases button. Closing door releases push bu...
Office lock—Turn button locking. Turning button locks outside knob requiring use of key until button is manually unlocked. Inside knob always free.
Classroom lock - Latchbolt is retracted by knob/lever from either side unless outside is locked by key. Outside is unlocked by key. Inside knob/lever is always free for immediate egress. Auxiliary ...
Entry double locking—Dead bolt thrown or retracted by key in upper lock from outside or by inside turn. Deadlocking latch retracted by key in outer knob/lever when locked by pushing button in inner...
Office lock—Turn button locking. Turning button locks outside knob requiring use of key until button is manually unlocked. Inside knob always free.
Electrically locking and unlocking outside lever (inside and outside cylinders) - Outside lever continuously locked (EL) or unlocked (EU) by 12 or 24V DC. EL is fail safe (power failure allows out...
Vestibule/Classroom Security lock - Latch retracted by key from outside when outside knob is locked by key in inside knob. Inside knob is always unlocked.
Q330-168 SFIC Tailpiece (throw member for levers) Q330-169 SFIC Tailpiece (throw member for knobs) 
At one time we offered a 9453 function in several different lever, knob and grip handleset designs. A wide variety of trim offerings were available. The mortise lockcase was a smaller version of th...
The dimension between the center of the deadbolt bore and the knobset bore is 4".  See template FH100 attached here for more dimensions.
Inside knob and bushing: 09-402 plus design and finishOutside knob: 09-401 plus design and finish
You can order an L lock with a lever on one side and knob on the other as long as it's still rose by rose, or escutcheon by escutcheon (must be same style escutcheon). EXCEPTIONS: Knob trim o...
Includes the SL1 lever on one side and the SK1 knob trim on the other side.
Make sure the lock AA batteries are good. 4.8 VDC or higher.
When in its “Active state”, the mechanical key switch can prevent USB connection. Make sure the lock key cylinder and tailpiece are properly installed.
Make sure the mechanical triangles on the back of the outside escutcheon are aligned properly.  See the installation instructions at www.schlage.com/support Schlage Technical Support.&nbs...
If the Schlage Utility Software pops up a "E201 error", just ignore it, and tap "Device Options" or update your firmware. See 78451  
Make sure the HHD/SUS is set to USB communication by checking the small icon right of the "No Device Connected" message.  The symbol should be a USB symbol when working with USB enable product...
All lockset cover torx screws will be T-15 Secure torx (with the center pin) Other torx screws sizes 10 and 12, will require T-20 Secure torx tool Torx screw kits are available for all sc...
Here are the steps to perform a General Z-Wave Device Exclusion:     From the Home screen, select Menu (Menu icon) and touch Devices     Select the SmartThings Hub  ...
For cross bores less than 2 1-8" we may need to remove the metal spacer to install the lock. Please follow the steps below.  Step 1. remove the screw that holds the spacer in place. Ste...
For W lock levers, you can choose whether or not to install the mounting posts.  This will also affect how the door is prepped so be sure to determine how you will install the locks befor...
The minimum stile for each lock will depend on the backset and the rose diameter/escutcheon width.  See the Schlage Minimum Stile Requirements for the minimum stile for eac...
The S200 series is a non-graded interconnect lock with levers only. Interconnected Locks are a lockset whose trim provides a means of simultaneous retraction of two or more bolts which may a...
The S200 series was introduced in 1995 and had a major design change in 2008 that included the cylinder, driver bar, deadbolt and interconnect plate.
The S200 series is similar to the now discontinued H-series which offered knobs only with the exception of the Levon (LEV) lever available on the H110.
Interconnected Locks: a lockset whose trim provides a means of simultaneous retraction of two or more bolts which may also be operated independently Medium duty Commercial, government or multi-...
Cylindrical Locks: a bored lockset whose latch or bolt locking mechanism is contained in the portion installed through the cross-bore Medium, high to extra heavy duty Commercial, mul...
Standard Schlage cylinders will not fit in Yale locks, but Schlage does offer special retrofit cylinder that, when ordered, can fit into specific Yale locks.  See below for retrofit options.  ...
The use of Panic Hardware and/or Fire Exit Hardware is required by the International Building Code (IBC) and NFPA 101 – The Life Safety Code, depending on which code and which edition of the code i...
You have a few different options to get all of your locks keyed alike. The first is to order form Build.com, they have any option to key your order alike at checkout for no extra charge. If you're ...
A lock specified by a cylinder suffix BDC will be supplied with a disposable small format construction core, see Figure 1 below.  There is no metal key but instead the BDC cylinder has a ...
A small format disposable core is used as a SFIC construction core that is for low security applications and can be thrown in the waste bin after use.
The JD YA6 tailpiece is intentionally designed such that the tailpiece cannot be installed at the same time as the cylinder.  Interchangeable cylinders assume that the lever and taipiece is i...
The ND40 does not have this option.  You will need to look at a mortise lock, L9496, or a deadbolt such as the B571.
Check the timing first, Where can I find timing instructions for the Falcon T lock? The keyspindle assembly for the T/RU571 and the T/RU561 w...
Replace the lock chassis as necessary for any T locks exhibiting this issue.  RU locks need to be replaced entirely. 
The 7500 mortise lock should be configured for NL function as shipped not as Classroom. See figure 4-3 in E996L instructions.
The MD latches are no longer available.  Pictures of the latches are not available. Illustrations of the latches are below.  
The MD Handleset latches are no longer available. Pictures of the MD Handleset latches are not available. Illustrations of the latches are below.
To remove the M lock trim follow the steps below in reverse.       The M lock spanner wrench is 021415.  Although this wrench is no longer available from&n...
SCHLAGE locks are available with the following backsets: Lock Series Lock Type                 ...
The knobs on these products are not interchangeable with each other.
Specify how the door is extended and the door thickness. Example 3" EE    Pricebook availability:    Extended Equally (EE)- Over 2"- 6" Extended Insid...
Schlage changed to the Everest 29 default keyway on March 4th, 2013. At that time, Everest 29 S123 became the default keyway for all Schlage locks. Everest product is still available but must be sp...
 The Schlage ND75 and ND95 locks require the chassis to be assembled and timed correctly for operation.  If the chassis has to be disassembled for any reason please refer to the Assembling Schlage ...
The Schlage Collins trim is now manufactured as a cast trim rather than stamped. This change results in a slightly larger trim at 2.90 inches in diameter as compared to the stamped trim at 2.72 i...
Medeco does offer a key-in-lever cylinder to fit the Schlage ND. You will need to contact Medeco for the cylinder Specify a key-in-lever cylinder to fit the Schlage ND lo...
The emergency keys are shipped with each lock.  The part numbers are; 61-509 standard and 61-510 large bow size.
A special change key in a hotel master key system which will allow access to one designated guest room, even if the lock is in the shut out mode.  It may also act as a shut out key for that room.
Classroom security lock - Latchbolt is retracted by knob/lever from either side unless locked by key from either side. When locked, latchbolt is retracted by key outside or knob/lever inside. Insid...
Classroom lock - Latch bolt operated by knob/lever from either side except when outside knob/lever is locked from outside by key. When outside knob/lever is locked, latch bolt is retracted by key f...
Office and inner entry lock with three-point latch - Latchbolt is retracted by knob/lever from either side unless outside is made inoperative by key outside or inside thumbturn. When outside is loc...
Classroom security lock with three-point latch - Latchbolt is retracted by knob/lever from either side unless locked by key from either side. When outside is locked, latchbolt is retracted by key a...
Entry/office lock—Turn/push button locking. Pushing and turning button locks outside knob requiring use of key until button is manually unlocked. Push button locking. Pushing button locks outside k...
Apartment entrance lock - Latchbolt is retracted by knob/lever from either side unless outside is locked by key from inside. When locked, latchbolt is retracted by key outside or knob/lever inside....
Storeroom lock - Latchbolt is retracted by key outside or by knob/lever inside. Outside knob/lever is always inoperative. Auxiliary latch deadlocks latchbolt when door is locked. Inside knob/lever ...
Entrance lock - Turn/push-button locking; pushing and turning button locks outside knob, requiring use of key until button is manually unlocked. Pushbutton locking; pushing button locks outside kno...
Entrance/office and inner entry lock - Latchbolt is retracted by knob/lever from either side unless outside is made inoperative by key outside or inside thumbturn. When outside is locked, latchbolt...
Schlage does not have a stainless steel/non-ferrous lock series. The only option that Allegion provides is the Grade 1 cylindrical Falcon X-Series. To order the Falcon X with the stainless st...
Most locks will have a standard door range they will install on, but occasionally customers will want to use them on thicker doors.  In order to do so, the extended door thick...
Doors that may be slightly under 1 3/4" thick may experience binding.  To resolve simply remove the spindle springs and discard.  Alternative solution is to install the OSU ferrule kit (L583-347)....
Hinge Spacing: All 4 1/2" and 5" butt hinge spacing 1. Opening heights 3'0" through 4'11 15/16" (one pair butt hinges) from under head CL 9 3/4" (top of door 9 5/8") from bottom of frame ...
Hinge Backset: On the frame = 5/16" On the door = 1/4"
Lock Spacing: All standard bored locks ANSI 115.2 (161, 61L type), for mortise lock ANSI 115.1 (86 type) all locations must be altered 3/8" lower, and standard strike (ASA type). 1. Opening ...
We do not offer a true night latch, storeroom or ANSI "03" function with this device. (Entrance by trim when latchbolt is retracted by key. Key removable only when locked.) This function would da...
Schlage does not have any cylinders certified to the BHMA A156.30 Grade 1 standard.  
ALWAYS put the PIM400 in LINK mode first. On a PIM400-TD2 press the LINK1 Button for door one, and LINK2 button for door 2. With a PIM400-485 you must use the SUS/HHD to select which door to...
1. To put the AD400 in LINK mode, hold down the RTE (Lever or crash bar see below) and press the # key on the key board, or present a card to the reader.       ...
2. AD400 requires a Request To Exit (RTX) signal to link - see the user guide instructions for the linking process.    For an AD400 to enter link mode, it must see the RTX...
   3. Check the AA battery level, if the AA batteries are below 4.7 volts the AD400 can fail to LINK.             Ins...
4. PIM400/AD400 COM400 plug could be damaged! The small pins in the Main PCB board connection for the RF COMM board can get bent during installation of the RF COM400 board. If the PINs are be...
To convert the Von Duprin 9975NL(Night Latch or Storeroom) to 9975L (Classroom) exit function follow these steps (Note: the mortise lock is shipped as Night Latch from the factory): Turn the NL ...
To convert the Von Duprin 9975L to 9975NL exit function follow these steps (Note: the mortise lock is shipped as Night Latch from the factory): Turn the NL screw on 7500 mortise lock counter clo...
The Von Duprin 7500 mortise lock body ships in the NL mode.  Either the function of 7500 lock body has not been changed to the Classroom function or the NL Drive screw is not all the way down. Step...
  Tips for changing the function: The NL Drive screw will not be visible when lock body is set to Classroom function There is locktite on the screw that makes it seem like its turned down enou...
The Schlage AL-Series SFIC locks require one (1) small format spacer (D500-000) for 7-pin cores and two (2) small format spacers for 6-pin cores.  When these spacers are not ins...
The AL53 and ND53 is not designed to be locked from the outside with a key. Key operation: When the button is pushed then the key will unlock the outside lever. When the button is pushed and...
AL-Series and discontinued D Lever-Series locks use castle nuts to hold the chassis to the spring cages and to keep the chassis positioned in the door. This causes confusion at times when the lock ...
Electrically locking and unlocking both levers (inside and outside cylinders) - Both levers continuously locked (EL) or unlocked (EU) by 12 or 24V DC. EL is fail safe (power failure allows outside ...
Electrically locking and unlocking both levers (inside and outside cylinder with deadbolt) - Both knobs/levers continuously locked (EL) or unlocked (EU) by 12 or 24V DC. EL is fail safe (power fail...
Electrically locking and unlocking both levers (outside cylinder, inside thumbturn with deadbolt) - Both knobs/levers continuously locked (EL) or unlocked (EU) by 12 or 24V DC. EL is fail safe (pow...
Hotel lock with 09-611 "Do not disturb" indicator - Latchbolt is operated by key outside or by knob/lever inside. Outside knob/lever is always fixed. Deadbolt is thrown or retracted by inside thumb...
M504-271 is the emergency key used to open a locked S40.
Schlage and Falcon double cylinder deadbolts have concealed screws to prevent tampering. The two methods used to conceal the thru-bolts are using screw caps or a faceplate. Use the below instructio...
KR
Closet Lock - Can be locked with key. Inside Knurled knob free for immediate egress unless outside lever locked with key.
Store lock - Key in either knob locks or unlocks both knobs.
Communicating lock - Key in either knob locks or unlocks each knob independently.
Entry lock—Push button locking. Button on inside locks outside knob until unlocked by key or by rotating inside knob.
L9071 LV9071 (ANSI F32) Classroom Security Lock  Latchbolt retracted by knob/lever from either side unless outside is locked by key from either side. Auxiliary latch deadlocks latchbolt when door...
Electrically locking and unlocking outside lever (inside and outside cylinder with deadbolt) - Outside lever continuously locked (EL) or unlocked (EU) by 12 or 24V DC. EL is fail safe (power failur...
Electrically locking and unlocking outside lever (outside cylinder, inside thumbturn with deadbolt) - Outside knob/lever continuously locked (EL) or unlocked (EU) by 12 or 24V DC. EL is fail safe (...
Electrically locking and unlocking outside lever (outside cylinder) - Outside lever continuously locked (EL) or unlocked (EU) by 12 or 24V DC. EL is fail safe (power failure allows outside knob/lev...
Electrically locking and unlocking both levers (outside cylinder) - Inside and outside knobs/levers continuously locked (EL) or unlocked (EU) by 12 or 24V DC. EL is fail safe (power failure allows ...
Storeroom lock with three-point latch - Latchbolt is retracted by outside knob/lever after key is inserted and rotated 280°, or anytime by inside knob/lever. Outside knob/lever is always inoperativ...
The knobs are available, part numbers listed below. 01-008 for a closed knob 01-009 for open levers 01-018 for cylinder knobs, LEV lever design not available in 01-018 01-026 for FSIC Specif...
Remove the inside rose then remove the two mounting screws and the inside and outside chassis will come off the door.  See Installation Instructions here.
Yes, if you remove the pick shield it will fit a 1 1/2" bore hole. To remove the pick shield, you remove the screw on the outer left behind the keyed plate and turn the pick shield to remove it.
Latch is broken, Please call #888-805-9837 or email consumer.support@allegion.com for a replacement latch.
Yes, several HHD's can be used with a single lock, as long as the HHD's have the same Coupling Password as the lock.
The HHD coupling password is set during the lock initialization, coupling process.
When the coupling password is changed the value is stored in the HHD and once coupled to a lock, the Coupling Password is also loaded in the lock/device memory.
The Coupling Password is compared whenever an HHD is trying to adjust lock configuration settings or downloading door programming files.
The date of manufacture printed on the chassis cover (see below), will determine if you have a revised or old chassis. Chassis manufactured mid-June 2013 will have the new improvements. The first...
When trying to program a CM lock, it may display an error code with a solid green light and 10 read flashes. This indicates the lock has already been programmed with computer software and manual pr...
1.Go to the main Hub page within the app. 2. Select the settings icon in the upper right corner. 3.Select your Wink Hub. 4.Scroll down and select Z-Wave Controls. 5. Press Z-wave exclusion  6....
Discontinued in late 2012.   When ADA requirements became required, Schlage created this retrofit lever to fit existing D knobs.  (Orbit, Plymouth, and Tulip knobs only).&n...
If the error "Device does not support this action - E802" appears when trying to couple the lock, it is generally because the user is not pressing the SW1 tamper button 3 times, but instead pressin...
In order to properly couple, the interior pushbutton must be held down while tapping the SW1 (tamper switch) three times.  This will enable the lock to couple to the HHD.
On power-up the CO-Series locksets will provide 5 quick RED Schlage Button flashes and 5 quick beeps to indicate that the electronics (credential reader) has been changed.  In order to recover...
When/If the electronics (Credential Reader) changed on a CO-Series lockset, the lock will respond with 3 RED Schlage button flashes and 3 beeps for any key press or credential presentation.&nb...
CO Reader Modules cannot be replaced by Reader Modules with a different credential type; for example, a magnetic swipe credential reader cannot be replaced with a proximity credential rea...
A Credential Reader MAY be replaced with another Credential Reader of the same type; however, a Factory Default Reset must be performed before the lock will function properly.
1) Make sure the lock batteries are more than 4.0 volts. The USB connection will not detect or communicate with a voltage lower than 4 volts. Many times a firmware update will draw d...
2) Make sure the SUS/HHD is set to communicate using USB connection mode in SUS.  You should see the familiar USB symbol on the SUS main Screen in the bottom right corner.  If you see a S...
3) When you update with NEW firmware replacing very OLD firmware a S1 RESET is suggested after the update. This initializes all the AD-Series memory locations to the new firmware. S1 is the ...
4) Make sure the HHD-USB cable is securely inserted into the HHD and into the lockset.  
5) Inspect the HHD-USB connector(s), ensure no pins are damaged, recessed or out of alignment. If a damaged cable is found customers should see their dealer for a replacement or they can order a re...
5) If working with a CO lockset, the mechanical key switch needs to be in its "Inactive" or normal position.  Ensure the triangle alignment on the front escutcheon and that...
Thermal Bow is a temporary condition which occurs in metal doors mainly due to the temperature differential from one side of the door to the other. This may occur in exterior doors when direct sun ...
Re-classing is the process by which an AD-Series device is able to change its lock type. The AD-Series has a modular architecture and a major benefit of this type of architecture is that it allows ...
This change was implemented in firmware package CO.A.6 (or later) to help the customer in the communication and coupling process between the CO200 (CO250) and the hand held device (HHD). ...
The green LED is to be lit up until the spindle (Triangles and Key Switch) are aligned properly; providing a visual indication of the problem.  
If the mechanical alignment of the triangles on the back of the outside escutcheon are not aligned, the CO200 or CO250 will not connect with the SUS/HHD and will appear to be unresponsive...
In firmware CO.A.6 (or later) the Schlage button on the CO200 (CO250) will turn green anytime that the spindle triangles on the front escutcheon are out of alignment or the mechanical key switch is...
When unlocking the CO200 door by mechanical key override, the green led will be continuously ON until the key is released. This will occur after firmware CO.A.6 (or later) has been installed int...
CO Reader Modules are not individually replaceable, nor can they be swapped between locks. The inside and outside assemblies of a CO lock are a matched/mated set and cannot be swapped to change rea...
A flat head screwdriver can be used or the 35-250 emergency key.
Indicator not extended Indicator extended
The indicator on a cylindrical hotel lock is a small pin that projects outward from the face of the cylinder plug (Figure 1) when the inside push button is depressed.  When this pin is ...
Falcon D series deadbolts will not accept Schlage Key-in-lever cylinders. The faceplate plug hole is smaller in diameter than the Schlage plug and does not fit flush when i...
For a Schlage "C"  keyway:  Specify "CP6" as the cylinder suffix when ordering  D100 or D200 locks (All other Schlage keyways are not available).
The L9466 Store/Utility Room lock can provide this functionality. Operation: Latchbolt retracted by knob/lever either side. Deadbolt thrown or retracted by key from either side. When the deadbolt ...
A control key is required to install or remove an interchangeable core from a housing or lever. The control key is identified by having "CONTROL" stamped on the bow. How to install and remove an i...
Key removable option is not available for any of Von Duprin aluminum mullions.
A lock is any device which prevents access or use by requiring special knowledge or equipment. Mechanical locks are mechanical devices which secure an opening by keeping a door closed until a relea...
Apartment Corridor Lock function is defined as a lock where the latch bolt operated by lever from either side, except when outside lever is made inoperative by a stop or mechanical means other than...
Putting a standard non-hotel cylinder in a L9485 or L9486 will change the operation of the lock to the L9480, storeroom lock with deadbolt.
4754, 4854 and the 9854 are electrified mullions and handed as noted below: 4754 is not handed: Prepared for two 4263 monitor strikes. Use with all Von Duprin rim panic devices 4854 is han...
Von Duprin KR (key removable) mullions requires a 1-1/8" or 1-1/4" mortise cylinder with the standard straight cam, the cam is not inverted. Please see chart below for part numbers. 
instructions
This HandNet for Windows message appears only when a HandKey 2 connects to it for the first time.  During the uploading of users from the HandKey 2 to HandNet, the software verifies the user d...
The Von Duprin 4754, 4854, 9954, and 9854 mullions can be converted or ordered with key removable option. KR54-F kit is the conversion kit to convert the above mullions to key removable mullion.
The blue lever tool remover, 24002693, is not shipped in every box. The existing wire spring lever removal tool will be included in every box.  
L9485:  Latchbolt retracted by key outside or by knob/lever inside. Outside knob/lever always fixed. Deadbolt thrown or retracted by inside thumbturn.  When deadbolt is thrown, all keys become ino...
L9080 is a mortise Storeroom Lock Latchbolt retracted by key outside or by knob/lever inside. Outside knob/lever is always inoperative. Auxiliary latch deadlocks latchbolt when door is clo...
MA581 is a Storeroom function mortise lock.
MA581 operation: Latchbolt operated by key from outside or by operating inside knob/lever. Outside knob/lever is always inoperative. Auxiliary latch deadlocks latchbolt when door is locked.
You can have your locks keyed alike by a locksmith, or hardware store. If ordering online, some retailers, such as build.com,  offer the "keyed alike" or "key code" option. If you want to use ...
There are (2) steps required to reset a Lock and allow it to be commissioned for reuse. First, the lock had to be deleted from the Engage site it was previously commissioned to. This can be ...
The lever removal tool can be used to remove levers in both the ND and the L Series mortise locks.
On August 15, 2012 Schlage began shipping a new, more ergonomic, lever removal tool to coincide with Phase 1 of the ND-Series improvement project.  This tool can be used for Schlage ND-Series ...
The S-Series and S200-Series outside keyed spindle was redesigned in September 2008.   For locks manufactured BEFORE September 2008    The S and S200 lever cylinders required cy...
A lock where the outside trim has the key cylinder incorporated into the lever itself.
a feature that allows an electrically operated lock to be released or engaged with a hand-operated key.
Entry/office lock - Latch bolt operated by knob/lever from either side except when outside knob/lever is made inoperative by buttons in face. When outside knob/lever is locked, latch bolt is retrac...
Classroom lock with three-point latch - Latchbolt is retracted by knob/lever from either side unless outside is locked by key. When outside is locked, latchbolt is retracted by key and knob/lever o...
Entrance lock - Turn/push-button locking; pushing and turning button locks outside knob, requiring use of key until button is manually unlocked. Push-button locking; pushing button locks outside kn...
Faculty restroom lock with deadbolt - Latchbolt is operated by key outside or by knob/lever inside. Outside knob/lever is always fixed. Deadbolt is thrown or retracted by inside thumbturn. When dea...
Storeroom lock with deadbolt - Latchbolt is operated by key outside or by knob/lever inside. Outside knob/lever is always fixed. Deadbolt is operated by key outside or thumbturn inside. Turning ins...
L9050 LV9050 (ANSI F04) Entrance/Office Lock  Latchbolt retracted by knob/lever from either side unless outside is made inoperative by key outside or by turning inside thumbturn. When outside is l...
Entrance/office lock with deadbolt - Latchbolt is retracted by knob/lever from either side unless outside is locked by 20° rotation of thumbturn. Deadbolt is thrown or retracted by 90° rotation of ...
Classroom security lock with auxiliary latch - Latchbolt is operated by knob/lever from either side except when outside is locked by key from inside or outside. Deadbolt is retracted by key from i...
Classroom lock - Outside knob locked and unlocked by key. Inside knob always unlocked.
Classroom lock - Outside knob locked and unlocked by key. Inside knob always unlocked.
Institution Lock - Both knobs fixed. Entrance by key in either knob.
Installation is not correct. If the straight cam on the mortise cylinder is not inverted,  the latch may be forced out of the strike and cause the door to unlatch.  Please reference the ...
Causes for AA battery drain in CO-Series LOCKS - Possible Cause Fix/Corrective Actions  One of the four AA batteries was inserted reversed and the reserved battery drains the other batteries. ...
Causes for AA battery drain in AD-Series LOCKS Possible Cause Fix/Corrective Action 1)      One the four (or eight) AA was inserted reversed and the rese...
Followings could cause the Chexit device to go into alarm after the rearm time: Chexit devices shipped after 8-24-2015 with motor driven: Module DPS LED is ON DPS switch contact is open: Close t...
Chexit devices shipped prior to 8-24-2015 with solenoid driven: Chexit device has a RX switch with a connector that needs to be connected to the Chexit module otherwise the alarm will sound af...
The process to change the Credential Reader on an AD-Series lock is as follows: Note: To ensure firmware compatibility of the lock and reader, it is important that the firmware in the LOCK and the...
It is not possible to key SFIC and standard cylinders including Schlage FSIC into the same system.  A keyway name may be shared between the two key fami...
Falcon began offering an RX switch with its electrified functions beginning January 17th 2012.  To specify, add "RX" to the end of the part number. Example:  Storeroom Function...
The MA RX features a single switch within the chassis that will monitor both the inside and outside knob/lever.  The switch is only available as Normally Open (NO).
Schlage offers a High, Medium, and Low risk HSLR ligature Resistant trim offering for the L9000 and ND locks, Data Sheet.Schlage offers a Low to Medium Risk SL1/SK1 ligature resistant trim for...
High Risk Areas*Patient bedroomIn-suite bathroomIn-suite closetTime-out roomPatient difficult to manage; or risk of solitary and/or unsupervised areas.Medium risk areas*Living roomDining roomGroup ...
Easily move from a Wink Hub or Hub 2 to another compatible Z wave system.  On the newly established hub, simply follow the manufacturers instructions for a "general exclusion" and re enroll (a...